Re: Fusion discovery with multiple programs?
¿ªÔÆÌåÓýThank you for your reply Jason.??As I indicated in an earlier email each programs¡¯ fusion symbol has a unique IP ID. Thank you. On Jan 18, 2019, at 2:03 PM, jasonmussetter@... [Crestron] <Crestron@...> wrote:
|
Re: Fusion discovery with multiple programs?
¿ªÔÆÌåÓý? Interesting... Why have the 1 on the update digital? In Fusion class they had us pulse it at midnight. Do you know what the limit is for Fusion Room symbols in one program slot? The FSG folks had me set it up this way. They are super helpful, just very busy. They are contacting me Monday morning. Thanks for the info William.On Jan 18, 2019, at 1:01 PM, williamprice880@... [Crestron] <Crestron@...> wrote:
|
Re: Fusion discovery with multiple programs?
The GUID is separate than the IPID.? The SSI module will take care of the GUID being unique.? However, if you loaded the same program into multiple slots, then the modules are probably all defined on the same IP-ID, which can't work.
You can only have an IP-ID defined for one slot, not sharing.? So you either need to move them IP-ID in the code for slots 2-10 and recompile, so all slots have the Fusion SSI module on different IPID's from each other, or maybe do some IP-ID remapping. If all slots have the SSI module defined on same IPID, only the first slot is using it, and locking it out of the other ones since it can't be shared.? That is why you can only discover one program and not the others. |
Re: Fusion discovery with multiple programs?
I'm looking at my working setup Bottom parameters on the 2.5 SSI Here's what i got for CP3N Processor Type Standard Primary SSI NO Prefix_GUID Yes Append_Program_Slot Yes File Location Internal Fusion SSI ID 10d (11 for next one etc..) Scheduling ID 10d (I use a scheduling module so i increment that for every room as well) Use Time Sync No. My Ethernet offline manager is looped with the update request from the right side to "offline" on the left Digital Signal Update_System_Info on SSI module is set to 1 My fusion ids are set starting F0 and increment to F1 and F2 etc.... Finally my last SSI module has a [To_Program_Initt_Complete] digital signal that I actually send to CP3_USERPROGRAMINIT to let it know initialization is complete for all modules. Nothing else not GUI modules or else. |
Re: Fusion discovery with multiple programs?
toggle quoted message
Show quoted text
On Jan 18, 2019, at 12:37 PM, williamprice880@... [Crestron] <Crestron@...> wrote:
|
Re: Fusion discovery with multiple programs?
¿ªÔÆÌåÓýHi William,?They do have their own Fusion symbols but they were all from common code so the nine rooms have the same GUID. The help file says the GUID updater is now integral to the main SSI module so I assumed that that wouldn¡¯t be an issue. Any thoughts? Thank you. On Jan 18, 2019, at 12:37 PM, williamprice880@... [Crestron] <Crestron@...> wrote:
|
Re: Fusion discovery with multiple programs?
Additionally I use a different Fusion SSI ID for each slot or process plus I have a 1 on Digital Signal Update System Info on SSI 2.5. For the record, apart from the main program running on slot 1 I actually run a second slot with several rooms defined on them all with different IPID and SSI IDs. This is to follow room scheduling for rooms that do not have Crestron yet. In one case I have 6 rooms running on one slot zero issue. |
New file uploaded to Crestron
Hello,
This email message is a notification to let you know that a file has been uploaded to the Files area of the Crestron group. File : /Schedule Input From User WP.zip Uploaded by : williamprice880 <williamprice880@...> Description : Schedule input from user S+ WPrice version. Unlocked source file. You can access this file at the URL: To learn more about file sharing for your group, please visit: Regards, williamprice880 <williamprice880@...> |
Steamist shower and sauna control
Hey everyone, I have this device connected to the network and I am trying to control with crestron, in the application market they have a module but it does not make a connection in the IP table, The default port that cant be changed is 9761 and cannot be changed. Any help is appreciated. Thank you |
Re: Android TV
¿ªÔÆÌåÓýHi, ? I control my Nvidia Shield via CEC ¨C works perfect. I Control my Sony TV via Sony 2014 Bravia TV module. I was just playing around when I Notice I controlled my Shield w/o doing any programming from my Crestron HR-150. It must be CEC I send via my Sony TV. ? //S ? Fr?n: Crestron@... <Crestron@...>
? ? I was searching a solution for my shield TV, because IRUSB is not directly available
|