Date

New file uploaded to Crestron

 

Hello,

This email message is a notification to let you know that
a file has been uploaded to the Files area of the Crestron
group.

File : /IR Drivers/Toshiba TF-50A810U19.ir
Uploaded by : metdeathx <metdeathx@...>
Description : Toshiba 4K UHD Smart LED TV with HDR - Fire TV Edition
Discrete Power, Input, Channels, Amazon Video, Netflix, HBO, Playstation Vue Applications.

You can access this file at the URL:


To learn more about file sharing for your group, please visit:


Regards,

metdeathx <metdeathx@...>


Re: LG Commercial display control via SNMP

 

Hey Crestronfreak55!

Thanks for your response. File is loaded to Documents section of Files.

I ended up working through a workaround to get good old reliable RS232 to the displays with the system's designer, so SNMP is off the table at present.

Feel free to go over to labs and +1 my suggestion for an updated RVCD symbol though ;-)

Cheers
Phil.


New file uploaded to Crestron

 

Hello,

This email message is a notification to let you know that
a file has been uploaded to the Files area of the Crestron
group.

File : /Documents/webOS_SNMP_Command_UserGuide_V1.6.pdf
Uploaded by : philmoore_174 <phil@...>
Description : LG webOS SNMP control protocol doc

You can access this file at the URL:


To learn more about file sharing for your group, please visit:


Regards,

philmoore_174 <phil@...>


Re: Null Folder - Network Device Tree View

 

I saw it with a Pac2 that somehow jumped into slave mode while I was setting up cresnet ids for keypads. Once I took it back out of slave mode it was fine again


Re: Null Folder - Network Device Tree View

 

I saw this recently with a PMC3 on the cresnet (thermostat) showed as null.? I rebooted, reloaded firmware, and then swapped for a MC3 I bought off of ebay (buddy's house).


Looking for DMC-CO-HD / 8G+ faceplates

 

I recently purchased 2 new in box?DMC-CO-HD-PA 8G+ output cards for a home project only to find out upon receiving that neither came with faceplates. Various search attempts have failed to turn up much about "DMC-CO-HD-PA" in particular and why they didn't include plates. I have already reached out to Crestron support and was told that since the the DMC-CO-HD is discontinued as was the face plate however the engineers said that a "DMC-CATO-HD" or other single slot 8G+ plate would be a direct fit though the labels would be wrong. Multiple search of ebay and other internet sites have not turned up any plates for sale. Other than reaching out to a local dealer in the Baltimore/DC area does anyone here know where these could possibly be found? Thanks in advance!!


-Jeff

?


Re: Null Folder - Network Device Tree View

 

¿ªÔÆÌåÓý

I¡¯ve seen it happen with an ancient device that didn¡¯t report precisely as Toolbox expected it (iirc, it was a CNECI-4 or CNECI-4a where Toolbox was expecting it to report ?CNECI-4A

?

If you REPORTCRESNET in text console and compare the two side by side it should be pretty obvious.

?

Lincoln

?

--

Lincoln King-Cliby, CTS, DMC-E-4K/T/D
Commercial Market Director
Sr. Systems Architect | Crestron Certified Master Programmer (Platinum)
ControlWorks Consulting, LLC |

D: (+1)440.771.4807 | O: (+1)440.449.1100? | F: (+1)440.449.1106
Crestron Services Provider | Biamp Audia Certified | Extron Qualified Independent Programmer

?

From: Crestron@... [mailto:Crestron@...]
Sent: Friday, July 27, 2018 4:32 PM
To: Crestron@...
Subject: [Crestron] Null Folder - Network Device Tree View

?




Does anyone know why I am getting a Null folder on my network device tree view?

Cresnet devices are reporting fine, but non of the ethernet devices are reporting.

However, the processor is connected to all devices and everything is working as usual.

This is happening to all my RMC3s.





Null Folder - Network Device Tree View

 

Does anyone know why I am getting a Null folder on my network device tree view?
Cresnet devices are reporting fine, but non of the ethernet devices are reporting.
However, the processor is connected to all devices and everything is working as usual.
This is happening to all my RMC3s.


sonos line in Module V1.0

 

couple of questions-

  • does this work with Sonos 9.0 firmware?
  • if the zone is in a group will it pull out of the group?
  • What is the MAC address format?


TIA

Chap Cory


Issues to use the HEOS DENON module

 

Hellow every one I downloaded the Heos Denon module because I want to integrate a Heos Likn and Heos Amp for a client but I'm not sure if the module that is in the crestron market works, I tried to import the module in simple windows but it says that the version is not compatible so I would like to know if some one has used it?

Also I read that the module has some issues?


Re: NVX on Control Subnet

 

This probably doesn't answer your question, but just in case anyone is wondering, the DM-NVX-350/1 does not support VLANs, tagging, and etc.? I myself was hoping to use the built in LAN port on a pair of DM-NVX-351s connected by a fiber link to get Ethernet to the remote end.? But when I had to use VLANs at the remote site for other reasons, I had to run a dedicated Ethernet run.


Re: NVX on Control Subnet

 

Well I tried to get version number off of switch, but power was off at the jobsite all day.? I will try again next week (I'll be back there on Monday).? I did have a brief chance to look at the subscription list in 1 NVX unit before the power was cut off, and my subscription list was not populated.? I did not set an IP address on the switch as jcallaghan0176 mentioned and that could be the issues for that.? Also if you are going to control with SIMPL program than you'll need to set an IPID (I did this with Powershell).


Re: NVX on Control Subnet

 

You will want to set an IP on the switch as it needs a valid IP address for the querier to work properly. Other than that the IGMP is already available.


JVC KY-PZ100 IP Camera

 

Just a shot in the dark, but does anyone have a module to control a JVC KY-PZ100 IP Camera?? I could really use some help controlling this one as I'm a little daunted by the API that I've found online.


TIA for your help


Chris Cates


Re: Cisco Green "Join" Button

 

Anyone know for sure if this module works for audio only calls?


Re: Lots of buttons

 

¿ªÔÆÌåÓý

What Slip and Phil said: +1

?

Caleb Radecky | Manager, Online Products & Services
Crestron Silver Certified Programmer | DMC-D-4K | DMC-E-4K
ControlWorks Consulting, LLC | Crestron Services Provider | 701 Beta Dr. #22 Cleveland OH 44143
D. 440.771.4809 | O.440.449.1100 X1109 | F.440.449.1106 |

?

From: Crestron@... [mailto:Crestron@...]
Sent: Thursday, July 26, 2018 11:19
To: Crestron@...
Subject: [Crestron] Re: Lots of buttons

?

?

What Phil said: +1


iPlayer3

 

Haven't had any experience with the Color Kinetics iPlayer3.? The OFF command in the serial driver actually works as a toggle power command.? The module in the Application Market is the one I am using and hasn't been updated in 10 years.? Was looking to see if there is actually a discrete off command that anyone is aware of or what have people done as a work around? I was thinking of learning my way through the Color Player software to see if I could create a BLACK show, all colors at 0.? Just thought I would ask here before going down the rabbit hole for a single project.


Also, for anyone that is familiar with this software.? Is it possible to upload the running program from the iPlayer3, so that programming can be done off site?


Re: Lots of buttons

 

What Phil said: +1


Re: Lots of buttons

 

What I would do in this case is have 1 subpage for the mic button, apply it multiple times to the page, and use subpage offsets to differentiate each position.


On Thu, Jul 26, 2018 at 10:57 AM jjustinhill@... [Crestron] <Crestron@...> wrote:
?

Having an issue with a project loaded to a DM-DGE-200-C. Customer is expecting an aerial view map of a 400 seat auditorium, each seating having a microphone, with an indicator for the mic state at each seat. Have this programmed but the subpage with 400+ advanced buttons on it is a bear to work with in VTPro and when we load it to the DGE-200 it will cause the project to freeze and reload. Device does not reboot, just reloads the project. Tried on a DGE-100 as well with the same results.

Anyone know if these is a limit to the number of buttons a single subpage should have with SmartGraphics? Anyone create something similar before and have a way to help manage resources to make this functional?

I seem to remember some recommendation about making everything a page in SG and only shared resources a subpage? In the iSys days we usually made a single page for the project and everything was a subpage, seem to remember this is not the recommended method with SG. Any help is greatly appreciated.



Lots of buttons

 

Having an issue with a project loaded to a DM-DGE-200-C. Customer is expecting an aerial view map of a 400 seat auditorium, each seating having a microphone, with an indicator for the mic state at each seat. Have this programmed but the subpage with 400+ advanced buttons on it is a bear to work with in VTPro and when we load it to the DGE-200 it will cause the project to freeze and reload. Device does not reboot, just reloads the project. Tried on a DGE-100 as well with the same results.

Anyone know if these is a limit to the number of buttons a single subpage should have with SmartGraphics? Anyone create something similar before and have a way to help manage resources to make this functional?

I seem to remember some recommendation about making everything a page in SG and only shared resources a subpage? In the iSys days we usually made a single page for the project and everything was a subpage, seem to remember this is not the recommended method with SG. Any help is greatly appreciated.