Re: Compile crashing

 

Deleting the SP Work folder before compiling has fixed this issue for me. I don't see it often but Clearone, DMPS3-300 and SX80 module would crash it Simpl.? Years ago this issue happed for an Extron module and never had time to dive into the real issue just deleted the SP Work folder and all was fine.

David




Re: Compile crashing

 

Have you tried deleting the SPIWork folder and doing a recompile-all?

On Tue, Feb 16, 2016 at 6:46 AM c_baram@... [Crestron] <Crestron@...> wrote:
?

Actually No,


it is only when I have both the Clearone and the Cisco module, if I have just one or the other it compiles fine. If I change the order of the modules in the program tree it crashes during compile of the whichever module is last. Also I encountered this problem when I had previous versions of both and hoped that when I put the latest versions of each (one at a time, then ultimately both) it would solve the issue but it did not. I have even installed software on a computer that previously had never had Crestron software on it and same result.


Re: Compile crashing

 

Actually No,


it is only when I have both the Clearone and the Cisco module, if I have just one or the other it compiles fine. If I change the order of the modules in the program tree it crashes during compile of the whichever module is last. Also I encountered this problem when I had previous versions of both and hoped that when I put the latest versions of each (one at a time, then ultimately both) it would solve the issue but it did not. I have even installed software on a computer that previously had never had Crestron software on it and same result.


Re: Compile crashing

 

"Can someone try and reproduce this"

I'm going to hazard two guesses - that you'll get a crash even if you remove the ClearOne processing module.

If you comment out the Cisco module, then it compiles without crashing, right?

? - Chip


Re: Autonomics, Sonos....

Heather Baiman
 

¿ªÔÆÌåÓý

I have programmed about 70 Crestron jobs with them and we sell one on just about every Savant job as well.

?

The original MMS-2 had some hardware issues (hard drive, Ethernet card, power supply), which we still service, but the 'A' series have proven much more reliable.

?

As far as features and services, it's hard to beat them, plus they are Media Player compatible.? If you're selling a Crestron distributed audio system, then the price of the MMS-2A is a non-issue.

?

From: Crestron@... [mailto:Crestron@...]
Sent: Saturday, February 13, 2016 9:39 PM
To: Crestron@...
Subject: Re: [Crestron] Autonomics, Sonos....

?




In the end and based on all the replies, i gather that Autonomics is still a good bank for the buck despite it's price point.

?

Can't thank you all enough for sharing your opinion.

?

Cheers!

?

On Saturday, February 13, 2016 8:56 AM, "Joe Vossen jkvossen@... [Crestron]" <Crestron@...> wrote:

?

?

We have install a few Autonomic units, clients love them


On Feb 12, 2016, at 9:51 PM, mcjaran@... [Crestron] <Crestron@...> wrote:

Is Autonomics MMS2 or 5 still a good player for the money??

I don't want to offer my clients a product that has been replaced by newer more cost effective technology.

It seems that besides from the Crestron Integration part, even Sonos can give Autonomics a run for a lot less money.

Your opinion will be very much appreciated.

Thank you in advance!

?





============================================================================
Please refer to http://www.eeny.net/disclaimer.txt
for important disclosures regarding this electronic communication.
============================================================================


Re: External temp input for HVAC ctrl

 

Oh, sorry. I was thinking of the outdoor temp and setpoints. I don't believe there is a way to use an external input for the room temp.

On Tue, Feb 16, 2016 at 9:22 AM, Jason Melvin <jwmelvin@...> wrote:
Seems like it should work directly, i.e., the temp format for the CNX-Bx keypads is the same as the TSTAT.

On Tue, Feb 16, 2016 at 9:01 AM, tzroberts@... [Crestron] <Crestron@...> wrote:
?

Hi all, I have a system where the designer does not want to see any remote temp sensors for HVAC, but we do have CNX keypads in the walls. Is there anyway to use a CNX-xBTN keypad as a remote temp sensor for a CHV-TSTAT-EX via SimplWindows?
Thank You....gotta love designers :)





Re: External temp input for HVAC ctrl

 

Seems like it should work directly, i.e., the temp format for the CNX-Bx keypads is the same as the TSTAT.

On Tue, Feb 16, 2016 at 9:01 AM, tzroberts@... [Crestron] <Crestron@...> wrote:
?

Hi all, I have a system where the designer does not want to see any remote temp sensors for HVAC, but we do have CNX keypads in the walls. Is there anyway to use a CNX-xBTN keypad as a remote temp sensor for a CHV-TSTAT-EX via SimplWindows?
Thank You....gotta love designers :)




External temp input for HVAC ctrl

 

Hi all, I have a system where the designer does not want to see any remote temp sensors for HVAC, but we do have CNX keypads in the walls. Is there anyway to use a CNX-xBTN keypad as a remote temp sensor for a CHV-TSTAT-EX via SimplWindows?
Thank You....gotta love designers :)



Re: Compile crashing

 

Ok,

Rolling back either the Crestron Database or Device database various versions did not resolve issue.


Can someone try and reproduce this:

New project with:

-DMPS3-300-C

-ClearOne Converge Feedback Processor v1.7

-ClearOne Converge Dialing v1.7

-Cisco C-Series v2.6


just make symbols complete and compile and let me know if it crashes.


Re: Compile crashing

 

????

Ok, installed Crestron software on a pc never having had it installed before and same issue.

So to summarize:


-same code but with 2 Series DMPS: compiles fine

-with 3 Series DMPS3: crashes


- crash point is not during the same module, meaning if I compile with modules in one order (module a, b, c) and it crashes during the 'c' module point of compile (every time I try) then I reorder the modules placement to (module b, c, a) the crash then occurs during 'a' every time so I don't think this is caused by a specific?module.


Thoughts:

I think this is somehow related to the latest Crestron Database and simpl+ since that seems to be the point at which I started having issues. Back in January I needed to update a piece of code previously modified back in October 2015 that had the Crestron Password Module v1.1 and it consistently crashed when it processed that module, no matter which password module I attempted to replace it with it crashed until I replaced it with my own modified version of the Crestron Alpha Numeric Password module. I am going to try and roll back the Crestron Data base and see what happens.


Any other suggestions?



Re: a smoke from my CP2E..

 

¿ªÔÆÌåÓý

I'm not sure what goes wrong. 12V trigger from the projector goes to small relay and output from relay to versiport. So it's just a dry contact. Nothing else connected on versiport.

D¨¾a 15.2.2016 o 15:18 cfm@... [Crestron] nap¨ªsal(a):

?

"Switched on my projector yesterday and?in few seconds?I see the smoke comming from CP2E"

Did someone wire 120vAC to your versiports while you weren't looking?

? - Chip



OT **Microsoft Surface Tablet** No RT Version

 

Hey Guys!,


I am wondering why there are no talk about using a Microsoft Surface Tablet as an alternative to an iPad or Android tablet. ?With the price of microsoft surface tablet dropping in price like a Surface 2 or 3 around 150 or 200 and it run fully loaded Windows. ?I have a Dell Windows Tablet running Windows 8.1 and I been running XPanel on it for the last two weeks and havent had any issue. ?


Any well using Microsoft Windows Tablet?


Just wanted to know.


Re: Max Signals

 

¿ªÔÆÌåÓý

I saw reply from?oliver.hall@... and need to fix my answer.

This is the total number of analog steps that you can reach, that is from 0 to 65535.
You have to include the zero in the count.

So we have 16 bits that can have a maximum value of?1111111111111111?=65,535
2^16 = 65536 and since we start at 0 the largest value that can be in 16 bits is 65535 (giving a total of 65536 numbers).

Em 14 de fev de 2016, ¨¤s 21:20, Rafael Costa rafaelg.costa@... [Crestron] <Crestron@...> escreveu:

?

This is the total number of analog steps that you can reach, that is from 0 to 65534.
You have to include the zero in the count.

Em 28 de jan de 2016, ¨¤s 16:23, crestron_programmer@... [Crestron] <Crestron@...> escreveu:

?

Ok cool. Thanks Steve. I thought someone once said 65535 is the limit but it's not so, cool!

Thank you,


Re: Experience using "USB-EXT-DM Control v1.0" module with USB-EXT-DM?

 

¿ªÔÆÌåÓý

If you can send it to me that would be awesome ¨C Lincoln at controlworks dot com or (second option, enter my name in the box)

?

TIA,

?

Lincoln

?

--

Lincoln King-Cliby, CTS, DMC-E-4K/T/D

Commercial Market Director

Sr. Systems Architect | Crestron Certified Master Programmer (Gold)

ControlWorks Consulting, LLC

Crestron Services Provider | Biamp Audia Certified | Extron Control Professional

?

From: Crestron@... [mailto:Crestron@...]
Sent: Monday, February 15, 2016 6:47 PM
To: Crestron@...
Cc: Crestron@...
Subject: Re: [Crestron] RE: Experience using "USB-EXT-DM Control v1.0" module with USB-EXT-DM?

?




The dmps has to be told what network the usb ext reside on.? All the USB ext have to be on LAN or patched into a DM lan port.? You can't have some on one and some on another.? I've tried both methods and I still have problems with them pairing consistently.? I am in the process of replacing all of them with a different type.?? Crestron wrote a custom module for me.? You have to enter the network ID or whatever it is called into the module.? I can send it to you.? Or you can try calling Crestron and tell them you need the module for a dmps.? They may or may not know what you are talking about.??

On Feb 15, 2016, at 5:16 PM, "Lincoln King-Cliby lincoln@... [Crestron]" <Crestron@...> wrote:

?

*ears perk up

?

It¡¯s a DMPS3 and explains why the same logic is confirmed working in another room (CP3) but not here. What needs to be done for/where can the custom module for a DMPS3?

?

Lincoln ?

--

Lincoln King-Cliby, CTS, DMC-E-4K/T/D

Commercial Market Director

Sr. Systems Architect | Crestron Certified Master Programmer (Gold)

ControlWorks Consulting, LLC

Crestron Services Provider | Biamp Audia Certified | Extron Control Professional

?

From: Crestron@... [mailto:Crestron@...]
Sent: Monday, February 15, 2016 12:09 PM
To: Crestron@...
Cc: 'Crestron@...' <Crestron@...>
Subject: Re: [Crestron] Experience using "USB-EXT-DM Control v1.0" module with USB-EXT-DM?

?





Keep in mind, use a stepper and break before make when pairing.?

Also, are you using a DMPS?? That requires a custom module.?

On Feb 15, 2016, at 7:50 AM, "Lincoln King-Cliby lincoln@... [Crestron]" <Crestron@...> wrote:

?

Have a project where these were added after our commissioning and need to change routing based on which laptop is routed to a smartboard.

?

The module looks uber straight forward but the techs onsite are reporting that it¡¯s not working. Last 6 characters of the MAC address have been confirmed. Haven¡¯t been able to get any information re: if the module is reporting an error or not.

?

Anyone have anything to watch out for? ?

?

--

Lincoln King-Cliby, CTS, DMC-E-4K/T/D

Commercial Market Director

Sr. Systems Architect | Crestron Certified Master Programmer (Gold)

ControlWorks Consulting, LLC

V: 440.449.1100 x1107 F: 440-449-1106 I:

Crestron Services Provider | Biamp Audia Certified | Extron Authorized Programmer

?









Re: Crestron App set up questions

 

Yes, all of the devices pointing to the same processor would have the same CIP port (default 41794).? I'm not sure why it would be working otherwise either unless they are ignoring your port settings (or trying the default without telling you).

On Mon, Feb 15, 2016 at 6:03 PM, mark.bagshaw@... [Crestron] <Crestron@...> wrote:
?

Thanks for this, Jeremy. Does this mean that I should configure port 41794 in the Crestron App on each of the android devices as well? At the moment I am using sequential port numbers starting at 41794 for the first device, 41795 for the second, etc. That seems to work okay, but given your explanation above, I'm not sure why!



Re: Vaddio One-Link, Cisco PHD cameras, and C40 question

 

I'm having the same or a very similar problem - DMPS3-300-C-AEC just installed, Cisco C40, two Cisco cameras connected over Vaddio One-Link units. The Cisco stuff is all existing and as far as I know was working fine. The cameras get where they are cycling on and off and the only thing that will fix it is to disconnect both HDMI input cables from the cameras to the codec.

Did anyone find a resolution to this issue?

Thanks,
David


Re: PRO3 Unable to connect to TCP servers

 

¿ªÔÆÌåÓý

I usually add a pro2 slave to the program and move all dedicated connections to it and then replace the pro2 withe the pro3. Seems to work better that way.?


On Feb 15, 2016, at 4:24 PM, Geoffrey Reynolds greynlds@... [Crestron] <Crestron@...> wrote:

?


Thanks for responding.

It looks like the entries in the log were just startup messages that resolved themselves as looking at the IP table in Toolbox indicated that all of those connections were online.? This pointed me to the program...

When I dropped the PRO3 in place of the PRO2 in my program, some of the TCP/IP Client signals got clobbered.? All the TX$ signals had to be re-entered for those symbols.? After getting those sorted out, everything seems to be working fine.? It's weird that those signals got clobbered, but everything else seems to be ok.

The only other odd thing I had noticed was that some IR devices connected to a DM-RMC-4K-100-C got copied to one of the IR ports on the processor, but I had cleaned that up prior to my initial program load.

Fortunately I had saved the old program (figuring there was the potential of some carnage...) so it was easy to open another copy of SIMPL and figure out the correct symbols to put on those TCP/IP Clients.

Now I can finally play around with SIMPL# when I get some time free.

Thanks again,
Geoff

On Mon, Feb 15, 2016 at 5:15 PM, slip.cougan@... [Crestron] <Crestron@...> wrote:
?

Can you ping those servers from a processor console session?



Re: Compile crashing

 

Try a different computer.? I've had Crestron tell me it my computer and they made me uninstall all Crestron software and reinstall.? Mine used to crash alot more but now does better.??

On Feb 15, 2016, at 5:02 PM, "c_baram@... [Crestron]" <Crestron@...> wrote:

?

Simpl Windows crashes on a compile. Situation is a client has a system designed with a DMPS-300-C and now is getting a new room but now with a DMPS3-300-C and other then moving from the 2 Series to the 3 Series DMPS the rooms are for all intensive purposes the same. So I did what I am guessing everyone here would do, I copied the previous code and replaced the processor updated the now disconnected routes, system/amp power, and DM Endpoint devices and went to compile only to end up with a Simpl Windows crash. Note that I can compile the previous code without issue and only after updating the processor to the 3 Series version of the DMPS do I have an issue. I have noticed at the point of the crash what module it was processing so I then commented out that module and wouldn't you know it completed the compile so I figured maybe that module was not 3 Series compatible so I replaced it with the latest and greatest from the application market. I replaced it and compiled and CRASH. Now you are going to ask what was the module... but I think it is irrelevant because I reordered some of the modules and this time the compiler made it past that module and crashed during another module it was processing.


My project files are?stored locally and NOT in a network share/dropbox/Onedrive type folder.

My Creston Info is:


SIMPL Windows:? 4.03.20
SIMPL+? 4.03.16
Path:? C:\Program Files (x86)\Crestron\Simpl

INCLUDE4_2SERIES.DAT Version Information:
??????? (2 Series)? : 1.80

INCLUDE4.DAT Version Information:
??????? (3 Series)? : 2.04.018

Data Files:
??????? Path: C:\Program Files (x86)\Crestron\Cresdb\Programming

symlib.tio 982? 01/28/2016 01:08:54PM

?iodev.tio 982? 01/28/2016 01:08:54PM

Other Crestron SW:

??????? Device Database: 72.00.001.00
??????? Crestron Database:? 54.05.005.00
??????? Crestron Toolbox: 2.41.252.00
??????? SIMPL+ Cross Compiler: 1.3


So anyone have any clue why and maybe a solution?


Thanks in advance!




Re: Experience using "USB-EXT-DM Control v1.0" module with USB-EXT-DM?

 

The dmps has to be told what network the usb ext reside on.? All the USB ext have to be on LAN or patched into a DM lan port.? You can't have some on one and some on another.? I've tried both methods and I still have problems with them pairing consistently.? I am in the process of replacing all of them with a different type.?? Crestron wrote a custom module for me.? You have to enter the network ID or whatever it is called into the module.? I can send it to you.? Or you can try calling Crestron and tell them you need the module for a dmps.? They may or may not know what you are talking about.??

On Feb 15, 2016, at 5:16 PM, "Lincoln King-Cliby lincoln@... [Crestron]" <Crestron@...> wrote:

?

*ears perk up

?

It¡¯s a DMPS3 and explains why the same logic is confirmed working in another room (CP3) but not here. What needs to be done for/where can the custom module for a DMPS3?

?

Lincoln ?

--

Lincoln King-Cliby, CTS, DMC-E-4K/T/D

Commercial Market Director

Sr. Systems Architect | Crestron Certified Master Programmer (Gold)

ControlWorks Consulting, LLC

Crestron Services Provider | Biamp Audia Certified | Extron Control Professional

?

From: Crestron@... [mailto:Crestron@...]
Sent: Monday, February 15, 2016 12:09 PM
To: Crestron@...
Cc: 'Crestron@...'
Subject: Re: [Crestron] Experience using "USB-EXT-DM Control v1.0" module with USB-EXT-DM?

?




Keep in mind, use a stepper and break before make when pairing.?

Also, are you using a DMPS?? That requires a custom module.?

On Feb 15, 2016, at 7:50 AM, "Lincoln King-Cliby lincoln@... [Crestron]" <Crestron@...> wrote:

?

Have a project where these were added after our commissioning and need to change routing based on which laptop is routed to a smartboard.

?

The module looks uber straight forward but the techs onsite are reporting that it¡¯s not working. Last 6 characters of the MAC address have been confirmed. Haven¡¯t been able to get any information re: if the module is reporting an error or not.

?

Anyone have anything to watch out for? ?

?

--

Lincoln King-Cliby, CTS, DMC-E-4K/T/D

Commercial Market Director

Sr. Systems Architect | Crestron Certified Master Programmer (Gold)

ControlWorks Consulting, LLC

V: 440.449.1100 x1107 F: 440-449-1106 I:

Crestron Services Provider | Biamp Audia Certified | Extron Authorized Programmer

?





Re: Crestron App set up questions

Michael S. Moran
 

¿ªÔÆÌåÓý

Well said.

?

One needs to remember that making everything easy, for the end user, is often times quite complex (at the back end).

?

Good Luck and Best regards,

?

msm

?

From: Crestron@... [mailto:Crestron@...]
Sent: Monday, February 15, 2016 6:00 PM
To: Crestron@...
Subject: [Crestron] Re: Crestron App set up questions

?

?

Hi Keith,

?

Please don't take this the wrong way ¨C on one level you are absolutely right ¨C but paying for a pro is all very well for those mega-rich people who install Crestron systems so they can sit on their fat arses and not get up off the lounge to change the TV channel or turn the lights on, but alas I'm not one of those people.

?

I installed my original Crestron system (and paid a substantial amount to a pro to do so) for two reasons, both related to the incredible benefits technology like this can bring to people with disability: first, I have a disability myself (quadriplegia) and I simply couldn't have lived alone when I was single without it, and second, I use it to showcase the latest technologies of this sort to show others what it can do and to encourage further investment in it. Given that, I am continually enhancing my system (at my own expense) to keep it up-to-date, and while I'm working full-time and certainly not poor, it would cost an arm and leg to have a pro come in every time I want to make what is often a fairly minor change (like adding an extra android device). On top of that it's not easy to find a Crestron professional who is not snowed under with work in my area.

?

I very much respect the value that professionals bring (I spent 28 years with IBM, the first five as a systems engineer which gave me the basic skills I have used to learn about Crestron), and as I well know, we all have to pay the bills! While it is no doubt not something professionals would want to hear, I have always thought that the Crestron system is way more complex than it needs to be (and of course some of the more recent alternatives, while not necessarily as fully functional as Crestron, are far easier for a relative novice to set up and manage). In particular, I find Simpl incredibly cumbersome compared to just about any other programming language ("simple" in name maybe, but certainly not in practice!).

?

Best wishes.