Re: Experience using "USB-EXT-DM Control v1.0" module with USB-EXT-DM?


 

The dmps has to be told what network the usb ext reside on.? All the USB ext have to be on LAN or patched into a DM lan port.? You can't have some on one and some on another.? I've tried both methods and I still have problems with them pairing consistently.? I am in the process of replacing all of them with a different type.?? Crestron wrote a custom module for me.? You have to enter the network ID or whatever it is called into the module.? I can send it to you.? Or you can try calling Crestron and tell them you need the module for a dmps.? They may or may not know what you are talking about.??

On Feb 15, 2016, at 5:16 PM, "Lincoln King-Cliby lincoln@... [Crestron]" <Crestron@...> wrote:

?

*ears perk up

?

It¡¯s a DMPS3 and explains why the same logic is confirmed working in another room (CP3) but not here. What needs to be done for/where can the custom module for a DMPS3?

?

Lincoln ?

--

Lincoln King-Cliby, CTS, DMC-E-4K/T/D

Commercial Market Director

Sr. Systems Architect | Crestron Certified Master Programmer (Gold)

ControlWorks Consulting, LLC

Crestron Services Provider | Biamp Audia Certified | Extron Control Professional

?

From: Crestron@... [mailto:Crestron@...]
Sent: Monday, February 15, 2016 12:09 PM
To: Crestron@...
Cc: 'Crestron@...'
Subject: Re: [Crestron] Experience using "USB-EXT-DM Control v1.0" module with USB-EXT-DM?

?




Keep in mind, use a stepper and break before make when pairing.?

Also, are you using a DMPS?? That requires a custom module.?

On Feb 15, 2016, at 7:50 AM, "Lincoln King-Cliby lincoln@... [Crestron]" <Crestron@...> wrote:

?

Have a project where these were added after our commissioning and need to change routing based on which laptop is routed to a smartboard.

?

The module looks uber straight forward but the techs onsite are reporting that it¡¯s not working. Last 6 characters of the MAC address have been confirmed. Haven¡¯t been able to get any information re: if the module is reporting an error or not.

?

Anyone have anything to watch out for? ?

?

--

Lincoln King-Cliby, CTS, DMC-E-4K/T/D

Commercial Market Director

Sr. Systems Architect | Crestron Certified Master Programmer (Gold)

ControlWorks Consulting, LLC

V: 440.449.1100 x1107 F: 440-449-1106 I:

Crestron Services Provider | Biamp Audia Certified | Extron Authorized Programmer

?