Re: Ctrl+H rant
Many are listed in the help if you search for 'shortcut', you'll see a topic for keyboard shortcuts
By
Heather Baiman <heather@...>
·
#178778
·
|
Re: Ctrl+H rant
Hmm.. pretty sure I was told I had to use Ctrl-Shift-G to get to a join number when this feature first came out, but you are right simply using Ctrl-G works fine. I forgot to include the Shift in the
By
Heather Baiman <heather@...>
·
#178777
·
|
Re: Ctrl+H rant
Wow. Didn't know about CTRL+SHIFT+B. I always just held down ENTER so that it would autoname the signals. Where are these shortcuts listed? herald@...> wrote:
By
Eric Walters
·
#178776
·
|
Re: Ctrl+H rant
Interesting! I knew and used Ctrl-Shift-B for auto-fill (which is undo-able, and will do ranges), but hadn't encountered Ctrl-Shift-H. Odd that there are two; odd that they name differently. Why you
By
Kool-Aid Drinker <herald@...>
·
#178775
·
|
Re: Bright Sign UDP
Thanks In Binary "Trigger" is 0) 0 1 1 1 0 1 0 0 1) 0 1 1 1 0 0 1 0 2) 0 1 1 0 1 0 0 1 3) 0 1 1 0 0 1 1 1 4) 0 1 1 0 0 1 1 1 5) 0 1 1 0 0 1 0 1 6) 0 1 1 1 0 0 1 0 do I need to covert this to Hex or
By
franzenel
·
#178774
·
|
Re: Bright Sign UDP
The port number is entered as a parameter in the detail view of the UDP symbol. For basic interaction between Crestron and a Bright Author project, use an SIO with its serial output connected to the
By
Kool-Aid Drinker <herald@...>
·
#178773
·
|
Re: Remote Acess by Apple Time Capsule
Tks for your help, the port it was enanble correct, but the simple detail was the problem, In toolbox, [function]/[webAcess] this function is not mark and the project to load not select, I make this
By
jedistoned
·
#178772
·
|
Re: Shared Resource Limitations
Biggest thing to be aware of is how you communicate to the 32x32. I have a job going now with two 32x32s at head end. In my case i was using the same code in each room and so I was defining all the
By
delcrestron
·
#178771
·
|
Re: Wifi Recommendation
Heh! I'm not sure I'm all that pretty after 8 months of frowning at the TSW ;-)
By
Heath Volmer <hvolmer@...>
·
#178770
·
|
Re: Wifi Recommendation
Dead simple web interface for anyone savvy (but if you're pretty as well, that couldn't hurt). There is also a CLI for tweaks if you're in a unique situation that needs it
By
Paul Cunningham <paul.cunningham@...>
·
#178769
·
|
Re: Wifi Recommendation
Heath, You won't have any trouble setting up a ruckus system. The director (hardware) had a beautiful web interface and configures the AP's for you. You may spend a couple hours tweaking (just because
By
kaybee302
·
#178768
·
|
Re: Wifi Recommendation
Paul, is that something a pretty-savvy guy can set up? How about the controller? I don't wind to wind up in a Cisco-style command line where I'm depending on "how-tos" to make it work. I've signed up
By
Heath Volmer <hvolmer@...>
·
#178767
·
|
Ctrl+H rant
Every now and then I mistype (always when I'm editing a touchpanel in Simpl) and Crestron decides to put a signal name on every join of the touchpanel, which is completely NOT undoable. Today I
By
Heather Baiman <heather@...>
·
#178766
·
|
Re: Wifi Recommendation
We use Ruckus exclusively (as does Access Networks FYI), with great roaming performance. The 7343 is our basic WAP and depending on needs it might get bumped up to a 7962 - I haven't played with the
By
Paul Cunningham <paul.cunningham@...>
·
#178765
·
|
Wifi Recommendation
Can someone recommend WAPs / controllers for a 4-WAP system, specifically some that will hand off connections between WAPs without hiccuping iPads? I'd like to work with something that I can set up
By
Heath Volmer <hvolmer@...>
·
#178764
·
|
Shared Resource Limitations
Hi folks, I'm talking with a client who is designing a multi-room system with a 32x32 DM, a few 3 series procs and about 20 TSW panels. He's experienced in AV (read: been burned before) and is
By
David Ives <david@...>
·
#178763
·
|
Re: Posted fix for sluggish TSWs
I just tried it on a TSW-1050. Can't see any difference. <jweather@...> wrote:
By
Kool-Aid Drinker <herald@...>
·
#178761
·
|
Re: Creating Epson serial module for Powerlite G5450
I have now disabled all polling with the exception of PWR?\x0D when the projector is powered off. I am not receiving any ERR responses now. Is there a buffer or something in the projector that
By
chuckperkinscrestron
·
#178762
·
|
Re: PTL4 to TPS4L
A PTL has deep-seated feeling of Prodigy-ness (a jumper, a resistor with a different value, or something). A quick diff of the TPS firmware blob vs. the PTL's shows... nothing. They use exactly the
By
Kool-Aid Drinker <herald@...>
·
#178760
·
|
Re: PTL4 to TPS4L
You are correct. I had only tested it with a 2-series (4.003.0015) since I simply loaded an existing program. I saved the program as a 3 series and tried having the PTL-4 talk to it and no dice, both
By
Heather Baiman <heather@...>
·
#178759
·
|