Re: Infinet EX Switch and 1 HP Motor
a switch is a switch you can control a 120v coil relay who control another bigger relay. you can control a power plant if you want just , you need.... neutral ( the white one )
By
seb_mtl
·
#176058
·
|
Infinet EX Switch and 1 HP Motor
Hi, I am trying to control a pool pump motor and notice the size limit for motors for the CLW-SWEX-P is 1/2 HP and pump is 1HP. My question is has anyone used or forsee any problems using a CLW-SWEX-P
By
jac777888
·
#176057
·
|
Re: Bacnet Comms with Honeywell hawk centraline. S/w coach ax
since march 3 2013 , the priority is managed in Crestron bacnet subsystem just tried today with latest database AND cp3 and it's working
By
seb_mtl
·
#176056
·
|
Re: symetrix jupiter 8 series
I made 6 or 7 big restaurants ( 350 people ) with that what do you want to know ?
By
seb_mtl
·
#176055
·
|
Re: subpage z-order ft-tps4
Been there, done that... The flip-top simply doesn't have that option. Which tells me that probably a separate team of engineers worked on the flip top model than the 4L. Other than that, I can't
By
fabiodaubermann
·
#176054
·
|
Re: symetrix jupiter 8 series
There's a standard one out there (CresDB I think) but be warned: Symetrix stuff is odd. Last time I did one it had a very strange characteristic. It only responded to serial commands via the 232 port
By
Daniel Fattorini <dan@...>
·
#176053
·
|
Re: Roomview Enabled Display Stupidity
@Jeremy In fairness to Vivitek, that issue was a Crestron issue, fixed in a SIMPL update (IIRC) about six months ago. It didn't affect just Vivitek, I believe BenQ and others were affected. And yes,
By
Phil Moore
·
#176052
·
|
D3 "link" levels between two switches
Is there any way to make one load's level always match another? I have a case where a slave switch needs to turn on it's load, as well as an adjacent load. I thought there was a way to say "level1 =
By
Heath Volmer <hvolmer@...>
·
#176051
·
|
subpage z-order ft-tps4
Does the flip-top TPS4 not have the option for sub-page z-order? I've always preferred the option for "Follow subpage-reference Z-order" for my projects, so I can always be sure of how the subpages
By
jaaronart
·
#176050
·
|
Re: On site with unfamiliar Denon Receiver
After a quick glance at the API, it appears to be using pretty standard Denon AVR commands, so I would assume most any modern Denon AVR module would work. . .at least for core features like power,
By
Steve Kaudle
·
#176049
·
|
On site with unfamiliar Denon Receiver
On Commercial job with a Denon DN-500AV receiver. Not familiar with this unit and curious if anyone know if any existing module(s), and if so which, work with this unit? TIA Alan
By
Audible Solutions
·
#176048
·
|
Re: Roomview Enabled Display Stupidity
Yeah, they just use the DB15 connector instead.... :)
By
eagrubbs
·
#176047
·
|
Re: Roomview Enabled Display Stupidity
My favorite is the Vivitek projectors that will select any input via the "RoomView Display" control module except for VGA. Nobody uses that anymore anyway...
By
Jeremy Weatherford
·
#176046
·
|
symetrix jupiter 8 series
hi does any one have a moduel to control a jupitor syries audio switcher from symetrics. will be willing to pay if need be thanks http://www.symetrix.co/products/jupiter-app-based-turn-key-dsp/
By
raid shamsa
·
#176045
·
|
Re: Roomview Enabled Display Stupidity
There is a setting for Epson projectors to leave comm's enabled when the projector is off. Menu > Extended > Standby Mode > Communications On
By
lincster2010
·
#176044
·
|
Re: Touchpanel control from
You could just do a init->equ, with a signal for each of the 9 locations, and each output enables a buffer that links your left/right/up/down/select with the appropriate 'next' action. So loc(1): left
By
weddellkw
·
#176043
·
|
Re: Touchpanel control from
That sounds great! A little beyond my Simpl abilities at the moment but I'm going to start trawling through the Help files straight away! Cheers
By
rlf79cm
·
#176042
·
|
Re: Touchpanel control from
This would be a good way to do and make a hella TT to take care of the logic behind it. JRW
By
jrw_96
·
#176041
·
|
Re: DMPS100
your first ip table is 127.0.0.1 is it a type mismatch ? have you set the same ip-id on the dmps and the tp ? {Paf} 2013/3/21 wes <wesam_helmy@...>
By
Rapha?l
·
#176040
·
|
Re: Touchpanel control from
How about an analog inc for left/right that increments by 1 and analog inc for up/down that increments by 3. Run them into a sum. Add conditional logic for a wrap around effect. Obviously there would
By
rdjr71
·
#176039
·
|