Re: SMW User Modules not showing up in the library
¿ªÔÆÌåÓýEvery time I have run into this problem, which has been more
times than I care to count, I have always traced it to a problem
with settings for the target control system in unc and s+ files.?
If you have lots of nesting then it can be PITA to trace all the
dependencies and get them fixed.? Sorry I can't offer any alternatives but when I've run into the issue it has always come down to the same solution. Jay On 2/27/2022 5:29 PM, ckangis wrote:
Hi All, |
SMW User Modules not showing up in the library
Hi All,
So the ultimate take-away is that I should suffer what I know and not try to eliminate and suffering...:( I tried moving to work only with project libraries, because my ancient/bloated SMW library was causing 'eternal' SMW start times and open project times...well that definitely fixed that issue, but the when it came to development and trying to retrieve previously created User modules that had other user modules and S+ embedded in them, it was just way too much of a beating to be worth it, so I've gone back to the devil I know... Of course now I have a new problem, that I never had before all this rigmarole, that I'd like to see if anyone has seen: Some User Modules will not show up in 4-series, and when opening a project with said module, the module is commented out and not visible to re-add in the SMW library. - Thus making the project unusable without some sort of resolution to this issue...:( *** I understand about Project Header/Target Control Classes, even for sub modules and S+ *** I worked thru one issue with Crestron Support last week and found that there was an S+ module that, although was set to 3/4-series and was re-Built/Save+Compile, we had to do an S+ 'Recompile ALL' to get it to work. So when I ran into a similar issue yesterday, I dutifully checked all the internal item settings and did a recompile all on the (1) S+ module in the User Module. Still Nothing!!! Has anyone seen anything like this? or have any other secret hand-shakes?? TIA!! |
S# http Request Timeout
When using an http client to make a request to a device in S#, is there a way to adjust the timeout before the Crestron system throws an exception that device has not responded in a timely manner?
?? ??? ?? try ?? ??? ?? { ?? ??? ??? ???? HttpClient client = new HttpClient(); ?? ??? ??? ???? HttpClientRequest request = new HttpClientRequest(); ?? ??? ??? ??? ?HttpClientResponse response; etc. ?? ???? ??? ??? response = client.Dispatch(request); etc. I'm trying to communicate with a battery operated IoT device. I'm finding that the device can go to sleep and when it does it takes a long time to respond.? I'm hoping to simply adjust the timeout value to give it time to wake up but I haven't been able to find a way to do it.? Doing all this in VS2008 so the code is compatible with a 3 series processor. Thanks in advance for the help Jay |
Re: Yamaha AVR IP control
Yes, that¡¯s what I was trying to convey here:?/g/crestron/message/243850
That module already has the correct input names as used by the new RX-AnA units I think. Rather than changing/replacing the existing input commands, I find it better to just add the new ones, thus expanding the module and making it more universal. That way I don¡¯t have to worry about having the correct version for a particular Yamaha AVR. Another such command example that¡¯s not consistent across models is the ¡°all channel stereo¡± mode. Rather than naming it ¡°All channel stereo¡± which would have been universal, it¡¯s called 5, 7 or 9 channel stereo, depending on the model! I therefore now have all three commands in my customised module, even though only one of the three will ever work for any one AVR. |
Re: Yamaha AVR IP control
Just a follow-up regarding the RX-AxA series of AVRs...
The 'Yamaha RX-A3010 IP v1.2' module seems to work fine... BUT It does not have the commands for the HDMI inputs. The previous generation of the AVRs used the 'AV1 thru AV7' input commands for the HDMI, but now the HDMI inputs are dedicated with the AVx inputs relegated for Component/Composite inputs (when/if available) You can alter the strings by changing the 'AVx' to 'HDMIx' and that seems to work fine... |
Re: Yamaha AVR IP control
YXC is just a HTTP API and by my understanding is similar if not the same as MusicCast API. When I was testing the CCD for my RX-A780 I was able to confirm with network captures that the device was being controlled over HTTP via GET/POST and not older TCP/50000 YNCA spec. You could likely get away with basic functions using on of the newer Yamaha CCDs if you dont want to write your own module. Best thing about YNX is that your not limited to a single connection as you are with YNCA on port 50000.
Yamaha Extended Control API Specification: |
NVX-363 resolutions
#nvx
HI,
Can someone confirm that a NVX-363/NVX-360 accepts 1080i 50Hz ? The specs shows 1080i 30Hz in the common resolutions. Thanks Best regards Chris? |
Re: CH5 Reserved Joins
#reservedjoins
#xpanel
#ch5
For reserved joins you can subscribe to the signal name instead of using the reserved join number when working with CH5. I (among others) use:l something like this: CrComLib.subscribeState('b', 'Csig.All_Control_Systems_Online_fb', (state) => { ? ? console.log(`Control system online: ${state}`); });? Check out the reserve join reference thats referenced by the CH5 developer microsite - I'm away from my computer and can't link directly. -Scott On Fri., Feb. 25, 2022, 6:59 p.m. Daniel Portugal, <joyousdan@...> wrote: So I've gotten my Ch5 angular project to upload and show up on the TSW1060. |
CH5 Reserved Joins
#reservedjoins
#xpanel
#ch5
So I've gotten my Ch5 angular project to upload and show up on the TSW1060.
I'm trying to detect if the touchpanel is Online with the system... reserved join 18494. But all i ever get is false, even though the processor says it's online. I've got this in the constructor off my app.component.ts: CrComLib.subscribeState('b', '18494', (value:any) =>{ console.log("Received from join 18494",value); this.ControlSystemOnline = value; }and this on the HTML ControlSystemOnline={{ControlSystemOnline}}Any suggestions?? |
Re: Yamaha AVR IP control
Ive used the YNCA protocol on both RS232 and IP. Both worked exceptionally well.
I am doing a job at the moment where I am controlling 10 WXA-50's. These are using the new YXC protocol. I haven't found any modules for them yet so writing my own unless someone else has one out there! |
Re: AM-200 Dropping Video >30mins
I had an install the beginning of last year where I had 5 AM200's. I had to return 2 of them for exhibiting similar issues.
Unlike your experience, Crestron wanted them back to investigate before saying anything so ended up having to purchase two more to get the job operational, however after having them for 2 days they were happy to refund them. I think I may have been on the bleeding edge of a batch issue. I have a 3200 sitting on my desk which I am about to evaluate, so far it looks ok. |
AM-200 Dropping Video >30mins
We've got a deployment of 16 AirMedia AM-200s in standalone rooms (a.k.a. no control system), where we've got an HDMI via a 3rd party HDBaseT extender plugged in to the AM's HDMI input. We've now had at least five of the sixteen exhibit the same symptom of the AirMedia stop outputting video after about 30 minutes when a user is plugged in via HDMI. I've verified that the device's clock is in sync, that the AirMedia Client "timeout" is set to "Never" and AMPS>System>Power Setting is set to "Always On."
We've RMA'd 4 out of the 5 so far, and Crestron hasn't told us that we're crazy or anything, but I also have a really hard time believing that we're having a failure rate of >30%. I'm hoping that the new AM-3200 won't have this issue, but I haven't begun deploying those yet. Has anyone else seen this behavior, and if so, have you found a cause (and/or solution)? |
Re: Pro3 recovery
¿ªÔÆÌåÓýHm, nobody? ? ? Von: [email protected] <[email protected]> Im Auftrag von Thorsten K?hler ? Hi, i?m trying to follow the instruction of Answer ID 5153 after a failed firmware load. ? In the case if there is no information for the IOP version listed after sending the ¡°ver -v¡± command, the instruction request to issue the command ¡°upload slot 9 fi¡±. However, the processor doesn?t seem to know this command since it responds with ¡°Bad or Incomplete Command (upload)¡±. ¡°Upload¡± is also not listed when issuing the ¡°help all¡± command. ? Any idea on how to complete the process? ? Thanks, Thorsten |