Published Voltage Fluctuations
4?Does Crestron have stated voltage findings on when processors or devices may experience lock ups when it comes to voltage fluctuations and/or voltages Neutral to Ground? ? For instance Lutron processors will lock up at 108V or below, Samsung TV¡¯s experience issues at 2V+ neutral to ground. ??have stated voltage findings on when your processors may experience lock ups when it comes to voltage fluctuations and/or voltages Neutral to Ground? ? For instance Lutron processors will lock up at 108V or below, Samsung TV¡¯s experience issues at 2V+ neutral to ground. ? |
Crestron APP block notification
#app
Is it possible in iOS / Android applications to prohibit / block the display of notifications with access to the settings so that the tablet user cannot access the connection settings. In other words, how to restrict access to the Crestron APP connection settings in a public tablet? |
Re: LiftMaster MyQ Garage Door openers
Ah I see what you're saying Tony.
I actually (and a friend also) found and extensively tested this issue ~4 years ago and beat on Crestron about it (mercilessly as usual!). My recollection is that they did fix this with the latest firmware. Also, I think part of the issue is resolved when you use the LINKSTATE extender on the Gateway module. If you're not using this, the unit definitely will not let the system know when it comes back online, at least until a new transition... Let me know it that works for you... |
Re: wake on lan
#crestron
thank you for your reply.
the processor and pc connected to the same managed switch , but in different subnets. i believe the solution must come from the network configuration, but i don't know how. what is the ip helper address ? i have a working module for wol in the same subnet. thank you, assaf? |
Re: Occupancy/motion sensor
Phil Millross
¿ªÔÆÌåÓýHey All,?This side of the pond a company call faradite make a great little unit? Again working with constant 24v psu and digital IO ??? On 9 Jan 2021, at 10:37, harryblackman@... wrote:
|
Re: Authentication Blocked IP
¿ªÔÆÌåÓýYes, nobody (except explicitly authorized) should be able to get on the blocking list of an internal Crestron processor¡ ? ? Von: [email protected] <[email protected]> Im Auftrag von Steve Kuehn ? We stop exposing ports to the Internet a long time ago because oversea sources were constantly pounding them.? We now use OpenVPN if we need remote access.? If you absolutely must do port forwarding, I advise you to use a router where you can set up firewall rules and then only allow certain IP addresses (e.g. your IP addresses) to pass. |
Re: LiftMaster MyQ Garage Door openers
The issue occurs with Simpl programs too, not just Crestron Home. However, it's usually easier to come up with a work-around with Simpl.
toggle quoted message
Show quoted text
The problem is caused by the INET-IOEX-RYIO not reporting its input states on program start, so a closed or shorted input will show as open after a program reboot. Correcting the feedback will require either opening then closing the input again, or power-cycling the IOEX. I normally run the IOEX's power through one of the relays, if they aren't both being used, then program that relay to always be on. That will cause a temporary interruption of power whenever the program restarts, and refresh the inputs' status. If both relays are being used, some other method could be used to reboot the IOEX, or I suppose rebooting the RF gateway would also work - although I haven't tried that. --- On Friday, January 8, 2021 at 11:29 AM, Evan Kontos wrote: |
Re: wake on lan
#crestron
Lots more information required.? ?Did you physically just connect the networks?? Are the pc and processor still on different subnets??
I've done WOL before across vlans but had to get the network Admin to setup an IP Helper address.? ? The magic packet string to send is easy to find.? There are modules on here that work fine.? Your network is the bigger issue.?? |
Re: Authentication Blocked IP
We stop exposing ports to the Internet a long time ago because oversea sources were constantly pounding them.? We now use OpenVPN if we need remote access.? If you absolutely must do port forwarding, I advise you to use a router where you can set up firewall rules and then only allow certain IP addresses (e.g. your IP addresses) to pass.
|
Re: Crestron Home (OS3) MMS 3e problem
We didn't have any issues with some MMS-3e zones not working with Crestron Home.? But we found the Crestron Home interface to be clumsy at best.? In particular, instead of just having one source name for each MMS zone, Crestron home broke the Source into a Source for Spotify, another for Pandora, and so forth -- Made for a very confusion source select page and no way to jump between different media types once you selected one.? We also had issues with the MMS-3e locking up constantly where we eventually had to replace it with some Sonos equipment.
Also, we have had some reliability issues with the MMS-3e where the Main Zone would work but the Zone-A and Zone-B would disappear from all interfaces including the Mirage App.? Eventually the Main zone would stop working too. |
Re: LiftMaster MyQ Garage Door openers
The device in my document is a simple MyQ wall button and my assumption is that it communicates the MyQ protocol over its buss as it wires directly into the same terminals as the more advanced wall control.
That's why I would *Expect* the opener to behave the same, BUT its all conjecture on my part....certainly an important detail to resolve!! And I look forward to the 20th!? Da-Da-Daaaaa!!!...:) |
Re: IR Driver For AT&T RC82V AT&T C71KW-400 Streaming box
Inconceivable!
toggle quoted message
Show quoted text
--- On Friday, January 8, 2021 at 4:04 PM, galcala wrote: |
Re: Occupancy/motion sensor
¿ªÔÆÌåÓýHow big a sensing area, what type of connectivity, and how important are aesthetics? ? You could put a GLS-ODT-C-CN in a surface pancake box using Cresnet if that¡¯s an option and aesthetics aren¡¯t critical. ? I¡¯ve used Visonic SPY-series PIRs around my house for really unobtrusive detection (exposed bit is about the size of a quarter) and mount it on a piece of polycarbonate or even wood cut to match the hole. 12VDC power and dry contact output (or you can tie one side of the dry contact to 12V and get a 12V wet output requiring only 3 conductors. ? Beware with the SPY they really don¡¯t like over voltage¡ ? -- Lincoln King-Cliby, CTS, DMC-E-4K/T/D ? From: [email protected] <[email protected]> On Behalf Of
MSTC
Sent: Friday, January 8, 2021 11:41 AM To: [email protected] Subject: [crestron] Occupancy/motion sensor ? I am trying to replace a ceiling mounted BEG automation PD11-KNX-FLAT bus occupancy sensor with something compatible with Crestron. ?Problem is it fits into a roughly 2" diameter hole in a concrete ceiling (no modification to structure
allowed). ?I am having no luck finding something that would fit. ?Any reference to a compatible product would be greatly appreciated. |
Re: WOL not working on CP4
¿ªÔÆÌåÓýNo, it is a TCP-Client (or UDP to be precise) in my case. I?m trying to send a WOL magic packet on port 9 to a PC to wake it up. ? Cheers, Thorsten ? Von: [email protected] <[email protected]> Im Auftrag von Jason Mussetter ? On Fri, Jan 8, 2021 at 05:54 AM, Jeremy Weatherford wrote:
Ahh, for TCP servers, not for clients.? That makes more sense now, I couldn't imagine lower ports being blocked from a TCP client symbol.? Thanks for the clarification on that Jeremy. I didn't the details of the error log to see that it was the a TCP server that was causing it, I just assumed it was a client. Control Systems Designer Mussetter Programming Services |
Re: WOL not working on CP4
On Fri, Jan 8, 2021 at 05:54 AM, Jeremy Weatherford wrote:
Ahh, for TCP servers, not for clients.? That makes more sense now, I couldn't imagine lower ports being blocked from a TCP client symbol.? Thanks for the clarification on that Jeremy. I didn't the details of the error log to see that it was the a TCP server that was causing it, I just assumed it was a client. ? -- Jason Mussetter Control Systems Designer Mussetter Programming Services |
Re: LiftMaster MyQ Garage Door openers
When you press the button on a LiftMaster wall controller it doesn¡¯t cause the opener to flash its lights or make any noise.? If the contract closure adapter is sending the same commands then there is an issue.? On the other hand if it sends commands that mimic what MyQ sends the the opener should give the proper audible and visual warnings.? If the contact closure adapter doesn¡¯t supply warnings the it is going to be up to the Crestron dealer to provide that as part of their overall solution. Wait until the 20th and I¡¯ll show you an alternative to the Crestron?INETS-IOEX-DOOR-BATT-W for under $20 ? Jay On Fri, Jan 8, 2021 at 9:23 AM ckangis <chris@...> wrote: Hi Jay, |