Hey guys, I recently passed my P301 entrance exam and have automatically been confirmed for the course (online) in about 2 and a half weeks time.? My concern is, I¡¯m really not sure if I¡¯m ready for it. My Simpl+ knowledge is pretty poor.
I¡¯m in 2 minds whether I should cancel and do it at a later date (once I¡¯ve had more Simpl+ experience/practice) or go through with it and hopefully I can keep up. What do you think I should do? Any advice would be appreciated? Thanks
|
Re: Web-based local temperature
If you are DYIer: Arduino Yun with DHT11 temp & hum sensor. Super cheap en very reliable.?
toggle quoted message
Show quoted text
On 9 Apr 2020, at 23:24, ckangis < chris@...> wrote:
Hi All, Anyone know of a *simple* way to harvest the Local area outdoor temperature from the web, into SMW to then put it on TSWs and TStats?? I'm looking for an alternative to the CHV-RSS because of cost, and what a pain it is to install them generally for this purpose... TIA!!
(I'd get it from Crestron's SmartGraphics weather app, but they havent updated it for basic features...I only started asking for that 9 years ago...they could update it, I'm sure...:(? ?)
|
I know this seems too simple to actually be the cause, but in the Lutron module's I've opened up, they use "login:" (all lower-case) to trigger sending the password. If you're actually receiving "LOGIN:" (all caps) it won't work. However, the module could easily be modified to fix that.
Which exact version of the Lutron module are you using?
toggle quoted message
Show quoted text
--- On Thursday, April 9, 2020 at 11:13 PM, AVMaster wrote:
Ok...so let me attempt to be more specific cause this is really weird.
Everything seems to be connecting just fine, if you view the TX$ and RX$ to and from the TCP client in debugger you can see the module connect and the Lutron processor responds with ¡®LOGIN:¡¯...it would be at that point I would expect the TX$ from the module to respond with the username entered in the core module but nothing happens...it just times out and responds with something like ¡®failed to receive expected response¡¯ or something along those lines. I¡¯ve done this a dozen times before but obviously something is wrong...
The real bummer about all this nonsense is that I only need to control just a few loads in a theater and a golf simulator, not even doing any extensive integration.
|
Ok...so let me attempt to be more specific cause this is really weird.
Everything seems to be connecting just fine, if you view the TX$ and RX$ to and from the TCP client in debugger you can see the module connect and the Lutron processor responds with ¡®LOGIN:¡¯...it would be at that point I would expect the TX$ from the module to respond with the username entered in the core module but nothing happens...it just times out and responds with something like ¡®failed to receive expected response¡¯ or something along those lines. ?I¡¯ve done this a dozen times before but obviously something is wrong...
The real bummer about all this nonsense is that I only need to control just a few loads in a theater and a golf simulator, not even doing any extensive integration.
|
Re: Matrix Analog vs DM Tool
In parallel ¨C out of an abundance of caution I won¡¯t post the detail from the SIMPL Windows Help here but compare and contrast the descriptions of the SBUF and ABUF relative to enable being high.
?
The ABUF propagates on transition of enable to high or when a new value on the left side arrives that does not match the value on the right side.
The SBUF propagates on any value change but not a transition of enable to high.
?
The SBUF/ABUF naming is one of those weird quirks of Crestron that has persisted since the beginning of time or thereabouts.
?
If you aren¡¯t using the enable on the ABUF and want all values to propagate you could also use just the SBUF instead. ?
?
--
Lincoln King-Cliby, CTS, DMC-E-4K/T/D
Commercial Market Director
Sr. Systems Architect | Crestron Certified Master Programmer (Platinum)
ControlWorks Consulting, LLC |
D: (+1)440.771.4807 | O: (+1)440.449.1100? | F: (+1)440.449.1106
Crestron Services Provider | Biamp Authorized Independent Programmers | Extron Qualified Independent Programmer
?
toggle quoted message
Show quoted text
From: [email protected] < [email protected]> On Behalf Of
AV_Programmer via groups.io
Sent: Thursday, April 9, 2020 7:26 PM
To: [email protected]
Subject: Re: [crestron] Matrix Analog vs DM Tool
?
Lincoln -?
You nailed the explanation as that is exactly what I am doing. ?Are you saying running a SBUF parallel or in-line with the ABUF to fix this issue?
Also, can you share what are the benefits at times and what are the issues for using solely?an ABUF?
Thanks in advanced!
AV_Programmer
|
Inherited a job that needs a few programming additions including some S#. Luckily the previous integrator was kind enough to leave the PGM archive on the processor.?
question is the Pro3 is on a pretty old FW 1.009.xxx i haven¡¯t upgraded a processor from that far back before. Wondering if anyone has had issues upgrading from old FW like that straight to current ?
Thanks!
|
One other thing to note is that newer QS versions require a crazy complex password like Cr3st0n!
|
Re: Matrix Analog vs DM Tool
Lincoln -?
You nailed the explanation as that is exactly what I am doing. ?Are you saying running a SBUF parallel or in-line with the ABUF to fix this issue?
Also, can you share what are the benefits at times and what are the issues for using solely?an ABUF?
Thanks in advanced!
AV_Programmer
|
CIPCommandprocessor.exe fails
Anyone ever seen these errors before?? I'm wondering if this processor was compromised.? I had port 41794 open when I first started seeing these errors and afterward found out about the CIP vulnerabilities.? Now, I have closed 41794 on the router, but still have issues with the processor locking up.? A reboot will get things working again.
?
13. Exception 'Data Abort' (0x4): Thread-Id=0cf1308a(pth=c0db2588), Proc-Id=09f0003e(pprc=c08f6c68) 'CIPCommandProcessor.exe', VM-active=09f0003e(pprc=c08f6c68) 'CIPCommandProcessor.exe' ?14. PC=4109b938(mscoree3_5.dll+0x0009b938) RA=4109be24(mscoree3_5.dll+0x0009be24) SP=030ff920, BVA=f9018bf4 ?15. Error: nk.exe # 2020-04-09 14:56:49? # WDG: CIPCommandProcessor shutting down unexpectedly. Do Not Start=0 ?16. Notice: CIPCommandProcessor.exe # 2020-04-09 14:56:53? # CresStore: Connections OK to redis ? ?17. Error: TLDM.exe # 2020-04-09 14:56:54? #? Ethernet Stack Application has already been registered ?18. Error: CIPCommandProcessor.exe # 2020-04-09 14:56:54? # SendTLDMAppRegisterMessage:Unable to Register with TLDM. Error code 0x1 ?19. Error: CIPCommandProcessor.exe # 2020-04-09 14:56:54? #? Unable to register application with the TLDM
?20. Info: CIPCommandProcessor.exe # 2020-04-09 14:56:54? # Got Router connected event ?21. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:54? # Command already exists:IPT. May not work correctly ?22. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:54? # Command already exists:GETIPTABLE. May not work correctly ?23. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:54? # Command already exists:SENDIPTABLE. May not work correctly ?24. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:54? # Command already exists:WHO. May not work correctly ?25. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:54? # Command already exists:TCPKEEPALIVE. May not work correctly ?26. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:54? # Command already exists:EDEBUG. May not work correctly ?27. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:54? # Command already exists:LISTENSTAT. May not work correctly ?28. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:54? # Command already exists:HEARTBEAT. May not work correctly ?29. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:54? # Command already exists:NUMNOHBRESP. May not work correctly ?30. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:54? # Command already exists:ADDPO. May not work correctly ?31. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:54? # Command already exists:REMPO. May not work correctly ?32. Notice: CIPCommandProcessor.exe # 2020-04-09 14:56:54? # Link established on CS ?33. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:54? # Command already exists:SHOWPORTMAP. May not work correctly ?34. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:54? # Command already exists:ISOLATENET. May not work correctly ?35. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:54? # Command already exists:RESERVEDL. May not work correctly ?36. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:54? # Command already exists:DHCPL. May not work correctly ?37. Notice: TLDM.exe # 2020-04-09 14:56:54? #? Event rcvd is 8 ?38. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:54? # Command already exists:CSROUT. May not work correctly ?39. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:54? # Command already exists:CSINA. May not work correctly ?40. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:54? # Command already exists:NATENA. May not work correctly ?41. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:SETCSAUTHENTICATION. May not work correctly ?42. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:CLEARCSAUTHENTICATION. May not work correctly ?43. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:GETCODE. May not work correctly ?44. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:BACNETADAPTER. May not work correctly ?45. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:SOCKETS. May not work correctly ?46. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:SECUREG. May not work correctly ?47. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:OCSP. May not work correctly ?48. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:ETHW. May not work correctly ?49. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:EWDGCONFIG. May not work correctly ?50. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:ADDM. May not work correctly ?51. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:REMM. May not work correctly ?52. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:MIPT. May not work correctly ?53. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:ADDP. May not work correctly ?54. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:REMP. May not work correctly ?55. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:DATASTORESTAT. May not work correctly ?56. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:DATASTOREIMPOR. May not work correctly ?57. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:DATASTOREEXPORT. May not work correctly ?58. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:DATASTOREDEL. May not work correctly ?59. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:ICMP. May not work correctly ?60. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:ICMPREDIRECT. May not work correctly ?61. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:CERTIF. May not work correctly ?62. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:8021XAU. May not work correctly ?63. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:8021XVAL. May not work correctly ?64. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:8021XMET. May not work correctly ?65. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:8021XDOM. May not work correctly ?66. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:8021XUSER. May not work correctly ?67. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:8021XPAS. May not work correctly ?68. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:8021XTRUS. May not work correctly ?69. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:8021XSEN. May not work correctly ?70. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:TESTDNS. May not work correctly ?71. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:AUTODIS. May not work correctly ?72. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:SERIALNUMBER. May not work correctly
|
Re: Matrix Analog vs DM Tool
You need to look at the signal path from the button press to the DM analog input and the propagation characteristics of each signal along the way.
?
Also how are you triggering the ENTER on the DM frame?
?
If you had an INIT connected directly to the DM analog the INIT should repropagate through to the DM frame and all Bueno when the button is pressed.
?
On the other hand, if you have analog buffer or crosspoint between the INIT and the switcher this is the expected behavior because those only propagate values
that have changed from the left to right ¨C eg if the left side is 1 and the right side is 1 the right side will never see a change no mantter how many times you init the left side ¨C this can be very handy in a lot of cases but cause trouble in others. There
are solutions like running a serial buffer instead of or in parallel with the ABUF, using XSIG symbols to encapsulate the analog value into a serial before routing it through a crosspoint, etc. but thos all have varying considerations as far as processor workload,
ease of maintenance of the program, etc.
?
--
Lincoln King-Cliby, CTS, DMC-E-4K/T/D
Commercial Market Director
Sr. Systems Architect | Crestron Certified Master Programmer (Platinum)
ControlWorks Consulting, LLC |
D: (+1)440.771.4807 | O: (+1)440.449.1100? | F: (+1)440.449.1106
Crestron Services Provider | Biamp Authorized Independent Programmers | Extron Qualified Independent Programmer
?
toggle quoted message
Show quoted text
From: [email protected] [mailto:[email protected]]
On Behalf Of AV_Programmer via groups.io
Sent: Thursday, April 09, 2020 5:55 PM
To: [email protected]
Subject: [crestron] Matrix Analog vs DM Tool
?
Folks -?
When routing analogs with a touch panel to a Matrix everything works great. When I use both DM Tool + Touch Panel things go weird.
If laptop is analog 1, and I press laptop on the touch panel, it routes. When I manually then use DM Tools to switch to input 2, when I press laptop on the touch panel again, it does not route. I have to route away from analog 1 (different source) then back
to laptop, then it takes.
Is this an issue where, even though I manually switch using DM Tools, if the analog value already propagated in SIMPL (laptop 1), sending the same value again will not repropagate and make the switch on the touch panel?
Any information would be greatly appreciated.
AV_Programmer
|
Folks -?
When routing analogs with a touch panel to a Matrix everything works great. When I use both DM Tool + Touch Panel things go weird.
If laptop is analog 1, and I press laptop on the touch panel, it routes. When I manually then use DM Tools to switch to input 2, when I press laptop on the touch panel again, it does not route. I have to route away from analog 1 (different source) then back to laptop, then it takes.
Is this an issue where, even though I manually switch using DM Tools, if the analog value already propagated in SIMPL (laptop 1), sending the same value again will not repropagate and make the switch on the touch panel?
Any information would be greatly appreciated.
AV_Programmer
|
Re: console command via Simpl
toggle quoted message
Show quoted text
On Fri, Apr 10, 2020 at 12:29 AM Erick Swihart < eswihart@...> wrote: SSH to 127.0.0.1. ? Issue whatever command you want. Use the SSH Client.?
Also if you have CTP enabled you can use a TCP/IP client on 41795.?
Can you be more specific please?
On Fri, Apr 10, 2020 at 12:22 AM Erick Swihart < eswihart@...> wrote: SSH Client the processor back to itself.? Should be able to execute. ? It's not for?debt collection or anything like this... I got a request from my client for a project that needs to be active for a period? of time for a system. it's not residential... . cant give out more details as its a hush hush project... Any other way it can be done ??
On Thu, Apr 9, 2020 at 11:52 PM Lincoln King-Cliby < lincoln@...> wrote:
Some commands are inhibited via the console symbol ¨C most of them kick back a ¡°blocked from this console type¡± but every once in awhile there¡¯s one that just doesn¡¯t do anything.
?
I would be surprised if they actually let you initialize a processor from programming that easily ¨C seems dangerous (and if you¡¯re doing it as a debt collection method I¡¯d very strongly suggest discussing the pitfalls and risks of that
with your attorney especially for residential systems)
?
--
Lincoln King-Cliby, CTS, DMC-E-4K/T/D
Commercial Market Director
Sr. Systems Architect | Crestron Certified Master Programmer (Platinum)
ControlWorks Consulting, LLC |
D: (+1)440.771.4807 | O: (+1)440.449.1100? | F: (+1)440.449.1106
Crestron Services Provider | Biamp Authorized Independent Programmers | Extron Qualified Independent Programmer
?
From: [email protected] <[email protected]> On Behalf Of
Micky Kummer
Sent: Thursday, April 9, 2020 4:38 PM
To: [email protected]
Subject: Re: [crestron] console command via Simpl
?
Yes
but after it reboots all comes back as nothing happened
?
have you tried sending?"initialize y\r"?
?
ok thanks
trying to send the command initialize
I get back "are you sure" Y or N
Sending Y but nothing happens
?
Under extended symbols, there¡¯s a ¡°console¡± symbol for just that.? Not all commands are allowed though.
|
Re: Web-based local temperature
I use the Crestron Weather Processor module (current version is 1.5). It uses either zip code or latitude/longitude and gives you the local temperature as well as a bunch of other info (windchill, heat index, etc).?
It's a little buggy on my MC4 but worked like a champ with an RMC3. I use it to control the ceiling fans in my house.?
|
Re: Web-based local temperature
Chris,
I don't have any direct experience with it, but this might work for you:
It looks like they limit how many times your account can call it per day, so it would probably make sense to create an account for each client.
Geoff
toggle quoted message
Show quoted text
On Thu, Apr 9, 2020 at 5:24 PM ckangis < chris@...> wrote: Hi All, Anyone know of a *simple* way to harvest the Local area outdoor temperature from the web, into SMW to then put it on TSWs and TStats?? I'm looking for an alternative to the CHV-RSS because of cost, and what a pain it is to install them generally for this purpose... TIA!!
(I'd get it from Crestron's SmartGraphics weather app, but they havent updated it for basic features...I only started asking for that 9 years ago...they could update it, I'm sure...:(? ?)
|
Re: console command via Simpl
SSH to 127.0.0.1. ? Issue whatever command you want. Use the SSH Client.?
Also if you have CTP enabled you can use a TCP/IP client on 41795.?
toggle quoted message
Show quoted text
Can you be more specific please?
On Fri, Apr 10, 2020 at 12:22 AM Erick Swihart < eswihart@...> wrote: SSH Client the processor back to itself.? Should be able to execute. ? It's not for?debt collection or anything like this... I got a request from my client for a project that needs to be active for a period? of time for a system. it's not residential... . cant give out more details as its a hush hush project... Any other way it can be done ??
On Thu, Apr 9, 2020 at 11:52 PM Lincoln King-Cliby < lincoln@...> wrote:
Some commands are inhibited via the console symbol ¨C most of them kick back a ¡°blocked from this console type¡± but every once in awhile there¡¯s one that just doesn¡¯t do anything.
?
I would be surprised if they actually let you initialize a processor from programming that easily ¨C seems dangerous (and if you¡¯re doing it as a debt collection method I¡¯d very strongly suggest discussing the pitfalls and risks of that
with your attorney especially for residential systems)
?
--
Lincoln King-Cliby, CTS, DMC-E-4K/T/D
Commercial Market Director
Sr. Systems Architect | Crestron Certified Master Programmer (Platinum)
ControlWorks Consulting, LLC |
D: (+1)440.771.4807 | O: (+1)440.449.1100? | F: (+1)440.449.1106
Crestron Services Provider | Biamp Authorized Independent Programmers | Extron Qualified Independent Programmer
?
From: [email protected] <[email protected]> On Behalf Of
Micky Kummer
Sent: Thursday, April 9, 2020 4:38 PM
To: [email protected]
Subject: Re: [crestron] console command via Simpl
?
Yes
but after it reboots all comes back as nothing happened
?
have you tried sending?"initialize y\r"?
?
ok thanks
trying to send the command initialize
I get back "are you sure" Y or N
Sending Y but nothing happens
?
Under extended symbols, there¡¯s a ¡°console¡± symbol for just that.? Not all commands are allowed though.
|
Re: console command via Simpl
Can you be more specific please?
toggle quoted message
Show quoted text
On Fri, Apr 10, 2020 at 12:22 AM Erick Swihart < eswihart@...> wrote: SSH Client the processor back to itself.? Should be able to execute. ? It's not for?debt collection or anything like this... I got a request from my client for a project that needs to be active for a period? of time for a system. it's not residential... . cant give out more details as its a hush hush project... Any other way it can be done ??
On Thu, Apr 9, 2020 at 11:52 PM Lincoln King-Cliby < lincoln@...> wrote:
Some commands are inhibited via the console symbol ¨C most of them kick back a ¡°blocked from this console type¡± but every once in awhile there¡¯s one that just doesn¡¯t do anything.
?
I would be surprised if they actually let you initialize a processor from programming that easily ¨C seems dangerous (and if you¡¯re doing it as a debt collection method I¡¯d very strongly suggest discussing the pitfalls and risks of that
with your attorney especially for residential systems)
?
--
Lincoln King-Cliby, CTS, DMC-E-4K/T/D
Commercial Market Director
Sr. Systems Architect | Crestron Certified Master Programmer (Platinum)
ControlWorks Consulting, LLC |
D: (+1)440.771.4807 | O: (+1)440.449.1100? | F: (+1)440.449.1106
Crestron Services Provider | Biamp Authorized Independent Programmers | Extron Qualified Independent Programmer
?
From: [email protected] <[email protected]> On Behalf Of
Micky Kummer
Sent: Thursday, April 9, 2020 4:38 PM
To: [email protected]
Subject: Re: [crestron] console command via Simpl
?
Yes
but after it reboots all comes back as nothing happened
?
have you tried sending?"initialize y\r"?
?
ok thanks
trying to send the command initialize
I get back "are you sure" Y or N
Sending Y but nothing happens
?
Under extended symbols, there¡¯s a ¡°console¡± symbol for just that.? Not all commands are allowed though.
|
Web-based local temperature
Hi All, Anyone know of a *simple* way to harvest the Local area outdoor temperature from the web, into SMW to then put it on TSWs and TStats?? I'm looking for an alternative to the CHV-RSS because of cost, and what a pain it is to install them generally for this purpose... TIA!!
(I'd get it from Crestron's SmartGraphics weather app, but they havent updated it for basic features...I only started asking for that 9 years ago...they could update it, I'm sure...:(? ?)
|
Re: console command via Simpl
SSH Client the processor back to itself.? Should be able to execute. ?
toggle quoted message
Show quoted text
It's not for?debt collection or anything like this... I got a request from my client for a project that needs to be active for a period? of time for a system. it's not residential... . cant give out more details as its a hush hush project... Any other way it can be done ??
On Thu, Apr 9, 2020 at 11:52 PM Lincoln King-Cliby < lincoln@...> wrote:
Some commands are inhibited via the console symbol ¨C most of them kick back a ¡°blocked from this console type¡± but every once in awhile there¡¯s one that just doesn¡¯t do anything.
?
I would be surprised if they actually let you initialize a processor from programming that easily ¨C seems dangerous (and if you¡¯re doing it as a debt collection method I¡¯d very strongly suggest discussing the pitfalls and risks of that
with your attorney especially for residential systems)
?
--
Lincoln King-Cliby, CTS, DMC-E-4K/T/D
Commercial Market Director
Sr. Systems Architect | Crestron Certified Master Programmer (Platinum)
ControlWorks Consulting, LLC |
D: (+1)440.771.4807 | O: (+1)440.449.1100? | F: (+1)440.449.1106
Crestron Services Provider | Biamp Authorized Independent Programmers | Extron Qualified Independent Programmer
?
From: [email protected] <[email protected]> On Behalf Of
Micky Kummer
Sent: Thursday, April 9, 2020 4:38 PM
To: [email protected]
Subject: Re: [crestron] console command via Simpl
?
Yes
but after it reboots all comes back as nothing happened
?
have you tried sending?"initialize y\r"?
?
ok thanks
trying to send the command initialize
I get back "are you sure" Y or N
Sending Y but nothing happens
?
Under extended symbols, there¡¯s a ¡°console¡± symbol for just that.? Not all commands are allowed though.
|
Re: console command via Simpl
It's not for?debt collection or anything like this... I got a request from my client for a project that needs to be active for a period? of time for a system. it's not residential... . cant give out more details as its a hush hush project... Any other way it can be done ??
toggle quoted message
Show quoted text
On Thu, Apr 9, 2020 at 11:52 PM Lincoln King-Cliby < lincoln@...> wrote:
Some commands are inhibited via the console symbol ¨C most of them kick back a ¡°blocked from this console type¡± but every once in awhile there¡¯s one that just doesn¡¯t do anything.
?
I would be surprised if they actually let you initialize a processor from programming that easily ¨C seems dangerous (and if you¡¯re doing it as a debt collection method I¡¯d very strongly suggest discussing the pitfalls and risks of that
with your attorney especially for residential systems)
?
--
Lincoln King-Cliby, CTS, DMC-E-4K/T/D
Commercial Market Director
Sr. Systems Architect | Crestron Certified Master Programmer (Platinum)
ControlWorks Consulting, LLC |
D: (+1)440.771.4807 | O: (+1)440.449.1100? | F: (+1)440.449.1106
Crestron Services Provider | Biamp Authorized Independent Programmers | Extron Qualified Independent Programmer
?
From: [email protected] <[email protected]> On Behalf Of
Micky Kummer
Sent: Thursday, April 9, 2020 4:38 PM
To: [email protected]
Subject: Re: [crestron] console command via Simpl
?
Yes
but after it reboots all comes back as nothing happened
?
have you tried sending?"initialize y\r"?
?
ok thanks
trying to send the command initialize
I get back "are you sure" Y or N
Sending Y but nothing happens
?
Under extended symbols, there¡¯s a ¡°console¡± symbol for just that.? Not all commands are allowed though.
|
Re: console command via Simpl
Some commands are inhibited via the console symbol ¨C most of them kick back a ¡°blocked from this console type¡± but every once in awhile there¡¯s one that just doesn¡¯t do anything.
?
I would be surprised if they actually let you initialize a processor from programming that easily ¨C seems dangerous (and if you¡¯re doing it as a debt collection method I¡¯d very strongly suggest discussing the pitfalls and risks of that
with your attorney especially for residential systems)
?
--
Lincoln King-Cliby, CTS, DMC-E-4K/T/D
Commercial Market Director
Sr. Systems Architect | Crestron Certified Master Programmer (Platinum)
ControlWorks Consulting, LLC |
D: (+1)440.771.4807 | O: (+1)440.449.1100? | F: (+1)440.449.1106
Crestron Services Provider | Biamp Authorized Independent Programmers | Extron Qualified Independent Programmer
?
toggle quoted message
Show quoted text
From: [email protected] < [email protected]> On Behalf Of
Micky Kummer
Sent: Thursday, April 9, 2020 4:38 PM
To: [email protected]
Subject: Re: [crestron] console command via Simpl
?
Yes
but after it reboots all comes back as nothing happened
?
have you tried sending?"initialize y\r"?
?
ok thanks
trying to send the command initialize
I get back "are you sure" Y or N
Sending Y but nothing happens
?
Under extended symbols, there¡¯s a ¡°console¡± symbol for just that.? Not all commands are allowed though.
|