Re: hr150 soft keys

Heather Baiman
 

¿ªÔÆÌåÓý

Across
Hit F1 on the symbol def, I think it shows it there?

Not sent from my flip phone

On Jan 17, 2019, at 6:53 PM, chap@... [Crestron] <Crestron@...> wrote:

are they numbered across or down?

Cant find in the docs.


hr150 soft keys

 

are they numbered across or down?

Cant find in the docs.


Steamist port for communication

 

Hi everyone,


I have a system that I have to connect to this device that is on the network, the manual says to use port 9761 but i look in the ip table and is not connecting.


Any help will be appreciated.


Thank you


Re: String Size

 

If you want to use the MSPs you will need to use separate serials that are 255 or smaller. ?You could put the part that doesn¡¯t change
sendrf,1,8,1
in one called something like Header$ and the rest of it in another like Payload$.

You can connect them to the TX$ using serial buffers with the same serial signal name on the outputs.

You can also send strings larger than 255 by using direct sockets in simpl+


From: <Crestron@...> on behalf of "Ricardo Ferraz ricardo.de.ferraz@... [Crestron]" <Crestron@...>
Reply-To: <Crestron@...>
Date: Thursday, January 17, 2019 at 11:28 AM
To: <Crestron@...>
Subject: [Crestron] String Size

?

Hello Guys,

I need to send this exemple of string with SIO feeding the TX$ TCP Client block

"sendrf,1,8,1,2663,9024,2760,8999,2760,9023,2736,9119,2664,9023,8352,3071,2760,9023,2736,9048,2735,9024,8351,3072,2736,9047,8399,3024,8352,3071,2736,9047,8328,3168,2663,9024,2759,9024,2736,9119,2664,9023,2760,8999,2760,9023,2736,9047,8400,3000,8423,3024,2736,65535\r\n"

But this string is over of 254d supported of the SIO block

Any ideas of how can I send it to the external RF gateway via IP...

Above the log erros from ToolBox.

27. Error: Cannot transmit packet: [06][01][12][00][73][65][6E][64][72][66][2C][32][2C][36][2C][31][2C][31][33][33]... to Slot-05.IP-ID-06.. Packet is too large. (0012:000D:0012)
? ? ?TimeStamp: 16:37:17? 1-17-19? ?UpTime: 0 days 00:17:17.51? Task: LogicPro
?28. Error: Cannot set permanent string value to "sendrf,2,6,1,1332,45...".? Maximum Length = 255, New Length would be 266.? Truncating string to 255 characters. (00AA:0000:00AA)
? ? ?TimeStamp: 16:37:18? 1-17-19? ?UpTime: 0 days 00:17:18.41? Task: LogicPro
?29. Error: Cannot transmit packet: [06][01][12][00][73][65][6E][64][72][66][2C][32][2C][36][2C][31][2C][31][33][33]... to Slot-05.IP-ID-06. Packet is too large. (0012:000D:0012)
? ? ?TimeStamp: 16:37:18? 1-17-19? ?UpTime: 0 days 00:17:18.48? Task: LogicPro
?30. Notice: **Restarting Program**
? ? ?TimeStamp: 16:39:17? 1-17-19? ?UpTime: 0 days 00:19:17.28? Task: ProgramR
?31. Error: Permanent String in symbol S-8.2 was declared as 300 characters - cannot be greater than 255 characters; truncating to 255 characters. (00AE:0000:00AE)
? ? ?TimeStamp: 16:39:17? 1-17-19? ?UpTime: 0 days 00:19:17.61? Task: LogicPro
?32. Error: Cannot set permanent string value to "sendrf,2,6,1,1332,45...".? Maximum Length = 255, New Length would be 266.? Truncating string to 255 characters. (00AA:0000:00AA)
? ? ?TimeStamp: 16:39:30? 1-17-19? ?UpTime: 0 days 00:19:30.36? Task: LogicPro
?33. Error: Cannot transmit packet: [06][01][12][00][73][65][6E][64][72][66][2C][32][2C][36][2C][31][2C][31][33][33]... to Slot-05.IP-ID-06. Packet is too large. (0012:000D:0012)
? ? ?TimeStamp: 16:39:30? 1-17-19? ?UpTime: 0 days 00:19:30..43? Task: LogicPro
?34. Error: Cannot set permanent string value to "sendrf,1,8,1,2663,90...".? Maximum Length = 255, New Length would be 266.? Truncating string to 255 characters. (00AA:0000:00AA)
? ? ?TimeStamp: 16:48:16? 1-17-19? ?UpTime: 0 days 00:28:16.81? Task: LogicPro
?35. Error: Cannot transmit packet: [06][01][12][00][73][65][6E][64][72][66][2C][31][2C][38][2C][31][2C][32][36][36]... to Slot-05.IP-ID-06. Packet is too large. (0012:000D:0012)
? ? ?TimeStamp: 16:48:16? 1-17-19? ?UpTime: 0 days 00:28:16.88? Task: LogicPro
?36. Notice: **Restarting Program**
? ? ?TimeStamp: 16:49:22? 1-17-19? ?UpTime: 0 days 00:29:22.43? Task: ProgramR
?37. Error: Permanent String in symbol S-8.2 was declared as 300 characters - cannot be greater than 255 characters; truncating to 255 characters. (00AE:0000:00AE)
? ? ?TimeStamp: 16:49:22? 1-17-19? ?UpTime: 0 days 00:29:22.76? Task: LogicPro
?38. Error: Cannot set permanent string value to "sendrf,2,6,1,1332,45...".? Maximum Length = 255, New Length would be 266.? Truncating string to 255 characters.. (00AA:0000:00AA)
? ? ?TimeStamp: 16:49:34? 1-17-19? ?UpTime: 0 days 00:29:34.48? Task: LogicPro
?39. Error: Cannot transmit packet: [06][01][12][00][73][65][6E][64][72][66][2C][32][2C][36][2C][31][2C][31][33][33]... to Slot-05.IP-ID-06. Packet is too large. (0012:000D:0012)
? ? ?TimeStamp: 16:49:34? 1-17-19? ?UpTime: 0 days 00:29:34.56? Task: LogicPro
?40. Error: Cannot set permanent string value to "sendrf,2,6,1,1332,45...".? Maximum Length = 255, New Length would be 266.? Truncating string to 255 characters. (00AA:0000:00AA)
? ? ?TimeStamp: 17:17:52? 1-17-19? ?UpTime: 0 days 00:57:52.09? Task: LogicPro
?41. Error: Cannot transmit packet: [06][01][12][00][73][65][6E][64][72][66][2C][32][2C][36][2C][31][2C][31][33][33].... to Slot-05.IP-ID-06. Packet is too large. (0012:000D:0012)
? ? ?TimeStamp: 17:17:52? 1-17-19? ?UpTime: 0 days 00:57:52.16? Task: LogicPro
Total Errors Logged = 41
End of System log

Rgds,
Ricardo


Cambridge Sound Masking System

 

Hello guys.

I need to take cost plan with sound masking installation QTPro series. I dont have time to get offer from Cambridge audio, and maybe some of you know what costs i need to take.

Can I take budget per meter, or maybe from pieces of speakers/zones?

Sound masking saystem is something new for me.


Re: String Size

 

You can send it on 2 lines from an SIO. Use the same digital signal on both lines, and send the string in 2 parts.


Re: connect direct to console in S+

 

thats what I figured. Just hoping that wasnt the case.

thanks though.


Re: connect direct to console in S+

 

¿ªÔÆÌåÓý

IIRC, no there¡¯s no way to talk to the console directly in S+, You¡¯d need to use a console symbol in SIMPL and pass that to SIMPL+.

?

You¡¯re probably getting the redirect because in the latest 3 series firmware, they shut down CTP.

?

Caleb Radecky | Manager, Online Products & Services
Crestron Silver Certified Programmer | DMC-D-4K | DMC-E-4K
ControlWorks Consulting, LLC | Crestron Services Provider | 701 Beta Dr. #22 Cleveland OH 44143
D. 440.771.4809 | O.440.449.1100 X1109 | F.440.449.1106 |

?

From: Crestron@... [mailto:Crestron@...]
Sent: Thursday, January 17, 2019 14:24
To: Crestron@...
Subject: [Crestron] connect direct to console in S+

?

?

I had a host name module working that would use sockets to connect to the console at 127.0.0.1. with port 41795 and grab the host name.?

I now get a REDIRECT:Connect to Secure Port 41797.\x0D\x0A.

If I set the port to 41797, nothing happens.

?

is there a way to connect to the console through s+ now?

?

thanks,

andrew

?


String Size

 

Hello Guys,

I need to send this exemple of string with SIO feeding the TX$ TCP Client block

"sendrf,1,8,1,2663,9024,2760,8999,2760,9023,2736,9119,2664,9023,8352,3071,2760,9023,2736,9048,2735,9024,8351,3072,2736,9047,8399,3024,8352,3071,2736,9047,8328,3168,2663,9024,2759,9024,2736,9119,2664,9023,2760,8999,2760,9023,2736,9047,8400,3000,8423,3024,2736,65535\r\n"

But this string is over of 254d supported of the SIO block

Any ideas of how can I send it to the external RF gateway via IP...

Above the log erros from ToolBox.

27. Error: Cannot transmit packet: [06][01][12][00][73][65][6E][64][72][66][2C][32][2C][36][2C][31][2C][31][33][33]... to Slot-05.IP-ID-06. Packet is too large. (0012:000D:0012)
? ? ?TimeStamp: 16:37:17? 1-17-19? ?UpTime: 0 days 00:17:17.51? Task: LogicPro
?28. Error: Cannot set permanent string value to "sendrf,2,6,1,1332,45...".? Maximum Length = 255, New Length would be 266.? Truncating string to 255 characters. (00AA:0000:00AA)
? ? ?TimeStamp: 16:37:18? 1-17-19? ?UpTime: 0 days 00:17:18.41? Task: LogicPro
?29. Error: Cannot transmit packet: [06][01][12][00][73][65][6E][64][72][66][2C][32][2C][36][2C][31][2C][31][33][33]... to Slot-05.IP-ID-06. Packet is too large. (0012:000D:0012)
? ? ?TimeStamp: 16:37:18? 1-17-19? ?UpTime: 0 days 00:17:18.48? Task: LogicPro
?30. Notice: **Restarting Program**
? ? ?TimeStamp: 16:39:17? 1-17-19? ?UpTime: 0 days 00:19:17.28? Task: ProgramR
?31. Error: Permanent String in symbol S-8.2 was declared as 300 characters - cannot be greater than 255 characters; truncating to 255 characters. (00AE:0000:00AE)
? ? ?TimeStamp: 16:39:17? 1-17-19? ?UpTime: 0 days 00:19:17.61? Task: LogicPro
?32. Error: Cannot set permanent string value to "sendrf,2,6,1,1332,45...".? Maximum Length = 255, New Length would be 266.? Truncating string to 255 characters. (00AA:0000:00AA)
? ? ?TimeStamp: 16:39:30? 1-17-19? ?UpTime: 0 days 00:19:30.36? Task: LogicPro
?33. Error: Cannot transmit packet: [06][01][12][00][73][65][6E][64][72][66][2C][32][2C][36][2C][31][2C][31][33][33]... to Slot-05.IP-ID-06. Packet is too large. (0012:000D:0012)
? ? ?TimeStamp: 16:39:30? 1-17-19? ?UpTime: 0 days 00:19:30.43? Task: LogicPro
?34. Error: Cannot set permanent string value to "sendrf,1,8,1,2663,90...".? Maximum Length = 255, New Length would be 266.? Truncating string to 255 characters. (00AA:0000:00AA)
? ? ?TimeStamp: 16:48:16? 1-17-19? ?UpTime: 0 days 00:28:16.81? Task: LogicPro
?35. Error: Cannot transmit packet: [06][01][12][00][73][65][6E][64][72][66][2C][31][2C][38][2C][31][2C][32][36][36]... to Slot-05.IP-ID-06. Packet is too large. (0012:000D:0012)
? ? ?TimeStamp: 16:48:16? 1-17-19? ?UpTime: 0 days 00:28:16.88? Task: LogicPro
?36. Notice: **Restarting Program**
? ? ?TimeStamp: 16:49:22? 1-17-19? ?UpTime: 0 days 00:29:22.43? Task: ProgramR
?37. Error: Permanent String in symbol S-8.2 was declared as 300 characters - cannot be greater than 255 characters; truncating to 255 characters. (00AE:0000:00AE)
? ? ?TimeStamp: 16:49:22? 1-17-19? ?UpTime: 0 days 00:29:22.76? Task: LogicPro
?38. Error: Cannot set permanent string value to "sendrf,2,6,1,1332,45...".? Maximum Length = 255, New Length would be 266.? Truncating string to 255 characters. (00AA:0000:00AA)
? ? ?TimeStamp: 16:49:34? 1-17-19? ?UpTime: 0 days 00:29:34.48? Task: LogicPro
?39. Error: Cannot transmit packet: [06][01][12][00][73][65][6E][64][72][66][2C][32][2C][36][2C][31][2C][31][33][33]... to Slot-05.IP-ID-06. Packet is too large. (0012:000D:0012)
? ? ?TimeStamp: 16:49:34? 1-17-19? ?UpTime: 0 days 00:29:34.56? Task: LogicPro
?40. Error: Cannot set permanent string value to "sendrf,2,6,1,1332,45...".? Maximum Length = 255, New Length would be 266.? Truncating string to 255 characters. (00AA:0000:00AA)
? ? ?TimeStamp: 17:17:52? 1-17-19? ?UpTime: 0 days 00:57:52.09? Task: LogicPro
?41. Error: Cannot transmit packet: [06][01][12][00][73][65][6E][64][72][66][2C][32][2C][36][2C][31][2C][31][33][33]... to Slot-05.IP-ID-06. Packet is too large. (0012:000D:0012)
? ? ?TimeStamp: 17:17:52? 1-17-19? ?UpTime: 0 days 00:57:52.16? Task: LogicPro
Total Errors Logged = 41
End of System log

Rgds,
Ricardo


connect direct to console in S+

 

I had a host name module working that would use sockets to connect to the console at 127.0.0.1. with port 41795 and grab the host name.?
I now get a REDIRECT:Connect to Secure Port 41797.\x0D\x0A.
If I set the port to 41797, nothing happens.

is there a way to connect to the console through s+ now?

thanks,
andrew



Re: Vaddio RoboSHOT 30 TCP/IP Control

 

I got a different module to actually work for me. It was from another program that someone else had sent me for a different project. The problem I was having with being able to use that Module before is that when I put it in my User Database or in the project folder so I could implement it into my project it wouldn't show up in the symbol library. So to rectify this I just opened both programs and copy/pasted it from one to the other. Now I just need to find out how to get my login to work on the camera. Thank you all for the help on this.


Re: Lots of buttons

 

That sounds like what I would do.? The way Smart Graphics handles a vector based button is completely ridiculous and a memory hog.

If you create a single subpage with a fully built microphone button/indicator on it, then put it on one page 400 times, then it's still only a single button.? It should handle it a lot better.

Not sure how you fit that many buttons on a page.? If it's just an 'indicator', then it may not be an issue.

For grins and giggles I put in a standard advanced button.? 48x48 pixels, and I put it on a subpage, then put it on a full page 360 times.? So, 360 buttons from a single subpage reference.

I then took that same button and put it into a single page.? Same deal.? 15 rows of 24 buttons to make it 360 buttons on the page.? The two different projects now looked identical.? One with all subpages, the other with all buttons.

The project which has the subpage references 360 times produced a file that is 16,784KB.? The file which used the actual button repeated 360 times is 43,744KB.? Well over twice the file size.

If that memory path follows through to a panel, then you shouldn't have the same issues as you have a lot less memory used for a single page.


AirMedia2/AM-200 Testimonials

 

Hi All,

We have a client that is interested in using AM-200 units in almost all of their conference rooms as the primary method of connecting laptops in the room to the display. They have a demo unit but have asked us if we have any testimonials from currently installed customers as to the performance of AirMedia2. In short - we don't. We have a couple installs out there of the AirMedia integrated DMPS, but those customers don't seem to use it enough to have an opinion on it.

So... do any of you guys have customers with an active AirMedia2 install base which might be willing to offer a few words to another customer about their experiences?


Thanks,

Michael


Re: MC3 Image

 

I think he's referring to the image file on the SD card that runs the MC3


Re: MC3 Image

 

¿ªÔÆÌåÓý

Jeroen,

Image as in graphical? there are several stock photos on Crestron website under the product webpage.?


Charles,




From: Crestron@... on behalf of jeroen.vandervelden@... [Crestron]
Sent: Thursday, January 17, 2019 8:35 AM
To: Crestron@...
Subject: [Crestron] MC3 Image
?
?

Hi,

Im looking for an MC3 Image file. I found bunch of Reddit and Yahoo topics but no links in it.
Does anyone has the image?

Br, Jeroen



Re: Lots of buttons

 

Revisiting this post. You guys are saying have 400 subpages on a single page, each with one button?


MC3 Image

 
Edited

Hi,
?
Im looking for an MC3 Image file. I found bunch of Reddit and Yahoo topics but no links in it.
Does anyone has the image?
?
Br, Jeroen

EDIT: Link:

?


Re: Grace Digital GDI-IRDT200

 

Anybody else using this device and able to get 2 way control?? Thanks!

On Thu, Jan 10, 2019 at 5:14 PM ktrdsl23 <ktrdsl23@...> wrote:
I use the Grace Digital Internet radio to listen to music, mainly Pandora.? I'm currently using the IR file to control it that is in the Crestron database.? Does anybody have a module that allows for 2way communication?? I'd love to be able to show what is playing on my panel similar to what I see on the Android/iOS app.? I have an older system and use a 2-series processor in case that matters.

Thanks!


Legrand MR232?

 

Anyone have experience with the Legrand MR232?? Connect with Termie and control it no problem, go through a CP3N and get nothing back except the last 2 or 3 digits of whatever command I send it. Put in the Crestron Module and get FB that says invalid entry (because as far as I can tell the module has no way to tell what # room it is in), but Preset 11 that is default for "All Off" works. Try to edit the user module in SIMPL+ and it is password protected..... looking for any advice before I throw it across the room.





Re: Crestron and Z-Wave controller

 

Thanks Jay,

I will try this at home!

I`m looing for an integration with "Domoticz" which runs on a Raspberry Pi-B.
It does accept HTTP commands but JSON looks more prommesing.

Jeroen