¿ªÔÆÌåÓý

ctrl + shift + ? for shortcuts
© 2025 Groups.io
Date
Re: CP4 TCP Connection
Martin, Yes 5000. Yes, PUTTY at port 5000 using RAW protocol. the most perplexing thing it that the Crestron will establish and keep a connection. Just no data back and forth.
By williamtejral@... · #248837 ·
Re: CP4 TCP Connection
I will check it out, thanks.
By williamtejral@... · #248836 ·
Re: understanding Teams integration with SIMPL?
They're used with the "Custom Controls" VtPro project, as described in Answer ID 1000880. There's also a good tutorial here <
By Tony Golden · #248835 ·
Re: understanding Teams integration with SIMPL?
Tony, have you found a use-case for the 'Touchpanel' D-A-S in/out signals?? or just using this as a holder for the extender? TIA!
By ckangis · #248834 ·
Re: understanding Teams integration with SIMPL?
Hi Mark Are the Cameras connected to the UC-Engine via USB? If so, have you tried using the reserved joins, as the 1Beyond cameras should now be supported. Please note that the Panel Type in VTPro
By ali@... · #248833 ·
Re: understanding Teams integration with SIMPL?
Thanks for that detail about the camera control Tony!!? ?I was writing my post as you were sending yours!...:)
By ckangis · #248832 ·
Re: understanding Teams integration with SIMPL?
I'm actually working on a quote for a project with Zoom integration, to this is very similar - Full Disc: I'm learning on this as well so I definitely would like others with more experience on the
By ckangis · #248831 ·
Re: understanding Teams integration with SIMPL?
Yes. Add the "UC-ENGINE-FLEX-TEAMS" symbol to the Simpl program, as if it were a touchpanel. Then add the "Teams Meeting Room Reserved Joins" extender, which will contain signals for controlling the
By Tony Golden · #248830 ·
Re: FGET 70 Series panels
Please post the working script when completed.? An example could be handy for someone in the future. Thanks, and thanks to those who helped figure it out :-)
By Tony Golden · #248829 ·
Re: FGET 70 Series panels
Thanks! That worked
By pbukowiec@... · #248828 ·
Re: FGET 70 Series panels
You can use hex escape sequences for '/' to get around this: CommunicationsSend "fget http:\x2F\x2Fserver.domain ...etc"
By ipha00@... · #248827 ·
Re: FGET 70 Series panels
Still shows up as commented out
By pbukowiec@... · #248826 ·
Re: FGET 70 Series panels
Wrap the path in quotes " "
By ZS · #248825 ·
Re: FGET 70 Series panels
So I got a little further, realized i need communicationsend at the beginning and now it does something. Problem I'm seeing is that i need the ftp:// in front and // treats everything after it as a
By pbukowiec@... · #248824 ·
FGET 70 Series panels
I'm trying to set up a toolbox script that will have my 70 series panels download their own firmware from the ftp site. I've gotten my string to work in text console, but can't get a toolbox script to
TSW1060 SD Card Image
Does anyone have the image for a TSW1060 that they could share with me. ?My personal panel is failing and I believe a new SD card will fix it but I do not have the image. Many thanks
By Adam · #248822 ·
understanding Teams integration with SIMPL?
i am working on a quote Teams/SIMPL -?UC-CX100-T there will a TP for Teams and a TP for SIMPL (4x4 switcher to 2 displays - i understand this part) it's the PTZ cameras i am struggling with there are
By mark kaye · #248821 ·
Re: CP4 TCP Connection
These Kramer boxes are telnet on port 5000, right? If you telnet from laptop you get responses and everything?
By Martin Szmulewicz · #248820 ·
Re: CP4 TCP Connection
/g/crestron/files/Telnet%20Handshake_compiled.zip
By Joda · #248819 ·
Re: CP4 TCP Connection
Hi, on which port do you connect the TCP Client? Some protocols need a special handshake. I'll upload a module for the telnet handshake in a minute, maybe that helps.
By Joda · #248818 ·