Re: $$$ for custom simpl# programming for TLS communication
https://www.haexperts.com/store/p7/Crestron_Text%2FEmail_%28SSL%2C_TLS%2C_Auth_Enabled%29_Module.html These guys also have a TLS email module. -Mike
By
Emperor Bob <empbob74@...>
·
#228344
·
|
Re: Tricky Problem with maybe Crosspoints
Right, he just needs to pull the NVRAM from one CP3 to the new CP3. Caleb Radecky | Manager, Online Products & Services Crestron Silver Certified Programmer | DMC-D-4K | DMC-E-4K ControlWorks
By
Caleb Radecky
·
#228342
·
|
Re: TV ONE C3-540 Coriomaster Video wall processor
http://www.tvone.com/control-module-request-form http://www.tvone.com/control-module-request-form
By
Will_R
·
#228341
·
|
Re: TV ONE C3-540 Coriomaster Video wall processor
The serial commands are easy, but IMO the unit presets and canvas are, well, much to be desired.
By
dbrichardson_bham
·
#228339
·
|
Re: Turning projector off everyday at 3am command
Ok great to know Thanks , Mingo
By
Mingo Manuela
·
#228337
·
|
TV ONE C3-540 Coriomaster Video wall processor
Has anyone worked with this device? Looking for a working module if anyone has one.
By
Robert Shackelford
·
#228338
·
|
Re: Toolbox Device Discovery Update
3.01.527 I tried it today with a site via Cisco VPN and it worked great Sent: Thursday, August 02, 2018 12:28 PM To: Crestron@... Subject: [Crestron] Re: Toolbox Device Discovery Update
By
Heather Baiman <heather@...>
·
#228336
·
|
Re: Toolbox Device Discovery Update
What version of toolbox are you using that you see this option in the device discovery tool? I do not see it in 3.01.481.00 (this message may be posted twice)
By
Evan P
·
#228346
·
|
Re: Toolbox Device Discovery Update
What version of toolbox are you using that you see this option in the device discovery tool? I'm running 3.01.481.00
By
Evan P
·
#228335
·
|
Re: Turning projector off everyday at 3am command
Agree on using WHEN for this purpose. Technically I suppose using WHEN vs PAST allows for the possibility of not executing if the processor is under heavy load and it can't interpret the WHEN on the
By
j.mussetter
·
#228334
·
|
Re: Tricky Problem with maybe Crosspoints
You can find out if there are crosspoints in the program by running the ¡°routesymstat¡± console command. It will list all the control and equipment crosspoints by ID and any connections between
By
Neil Dorin
·
#228333
·
|
Re: Tricky Problem with maybe Crosspoints
I¡¯d hedge a bet on ARAM values. We used to do that all the time ( before S# SQLite). It¡¯s probably some analog values that need some defaults set. Crestron@...> wrote:
By
nathan_hesson
·
#228332
·
|
Re: Tricky Problem with maybe Crosspoints
Run routesymstat from a console. This will give you a list of the crosspoints (if any)
By
slip.cougan@...
·
#228343
·
|
Re: $$$ for custom simpl# programming for TLS communication
Control Concepts http://www.controlconcepts.net
By
jeff
·
#228331
·
|
Re: Tricky Problem with maybe Crosspoints
Thanks for the responses, No i have no backup, i?m not shure if the programmer used crosspoints but it seems like, cause of the naming in the debugger. The RoomButtons triggers Signals like
By
piffko@...
·
#228330
·
|
Re: Turning projector off everyday at 3am command
Ok great thanks Thanks , Mingo
By
Mingo Manuela
·
#228329
·
|
Re: Turning projector off everyday at 3am command
The WHEN avoids this problem since it¡¯s a pulsed trigger at a specified time rather than the PAST¡¯s latched output. -- Lincoln King-Cliby, CTS, DMC-E-4K/T/D Commercial Market Director Sr. Systems
By
Lincoln King-Cliby
·
#228328
·
|
Re: Turning projector off everyday at 3am command
Lol ? ok thanks for the advice Thanks , Mingo
By
Mingo Manuela
·
#228327
·
|
Re: Turning projector off everyday at 3am command
"Clock Driver -> PAST(03:00:00:00s in parameter) -> One Shot-> Button presser-> Projector Power OFF" Be sure to keep in mind - if you load code after 3AM, the projector is going to turn off
By
chipmoody@...
·
#228326
·
|
Re: Turning projector off everyday at 3am command
Ok thanks Thanks , Mingo
By
Mingo Manuela
·
#228323
·
|