Date
Re: $$$ for custom simpl# programming for TLS communication
https://www.haexperts.com/store/p7/Crestron_Text%2FEmail_%28SSL%2C_TLS%2C_Auth_Enabled%29_Module.html These guys also have a TLS email module. -Mike
By Emperor Bob <empbob74@...> · #228344 ·
Re: Tricky Problem with maybe Crosspoints
Right, he just needs to pull the NVRAM from one CP3 to the new CP3. Caleb Radecky | Manager, Online Products & Services Crestron Silver Certified Programmer | DMC-D-4K | DMC-E-4K ControlWorks
By Caleb Radecky · #228342 ·
Re: TV ONE C3-540 Coriomaster Video wall processor
http://www.tvone.com/control-module-request-form http://www.tvone.com/control-module-request-form
By Will_R · #228341 ·
Re: TV ONE C3-540 Coriomaster Video wall processor
The serial commands are easy, but IMO the unit presets and canvas are, well, much to be desired.
By dbrichardson_bham · #228339 ·
Re: Turning projector off everyday at 3am command
Ok great to know Thanks , Mingo
By Mingo Manuela · #228337 ·
TV ONE C3-540 Coriomaster Video wall processor
Has anyone worked with this device? Looking for a working module if anyone has one.
By Robert Shackelford · #228338 ·
Re: Toolbox Device Discovery Update
3.01.527 I tried it today with a site via Cisco VPN and it worked great Sent: Thursday, August 02, 2018 12:28 PM To: Crestron@... Subject: [Crestron] Re: Toolbox Device Discovery Update
By Heather Baiman <heather@...> · #228336 ·
Re: Toolbox Device Discovery Update
What version of toolbox are you using that you see this option in the device discovery tool? I do not see it in 3.01.481.00 (this message may be posted twice)
By Evan P · #228346 ·
Re: Toolbox Device Discovery Update
What version of toolbox are you using that you see this option in the device discovery tool? I'm running 3.01.481.00
By Evan P · #228335 ·
Re: Turning projector off everyday at 3am command
Agree on using WHEN for this purpose. Technically I suppose using WHEN vs PAST allows for the possibility of not executing if the processor is under heavy load and it can't interpret the WHEN on the
By j.mussetter · #228334 ·
Re: Tricky Problem with maybe Crosspoints
You can find out if there are crosspoints in the program by running the ¡°routesymstat¡± console command. It will list all the control and equipment crosspoints by ID and any connections between
By Neil Dorin · #228333 ·
Re: Tricky Problem with maybe Crosspoints
I¡¯d hedge a bet on ARAM values. We used to do that all the time ( before S# SQLite). It¡¯s probably some analog values that need some defaults set. Crestron@...> wrote:
By nathan_hesson · #228332 ·
Re: Tricky Problem with maybe Crosspoints
Run routesymstat from a console. This will give you a list of the crosspoints (if any)
By slip.cougan@... · #228343 ·
Re: $$$ for custom simpl# programming for TLS communication
Control Concepts http://www.controlconcepts.net
By jeff · #228331 ·
Re: Tricky Problem with maybe Crosspoints
Thanks for the responses, No i have no backup, i?m not shure if the programmer used crosspoints but it seems like, cause of the naming in the debugger. The RoomButtons triggers Signals like
By piffko@... · #228330 ·
Re: Turning projector off everyday at 3am command
Ok great thanks Thanks , Mingo
By Mingo Manuela · #228329 ·
Re: Turning projector off everyday at 3am command
The WHEN avoids this problem since it¡¯s a pulsed trigger at a specified time rather than the PAST¡¯s latched output. -- Lincoln King-Cliby, CTS, DMC-E-4K/T/D Commercial Market Director Sr. Systems
By Lincoln King-Cliby · #228328 ·
Re: Turning projector off everyday at 3am command
Lol ? ok thanks for the advice Thanks , Mingo
By Mingo Manuela · #228327 ·
Re: Turning projector off everyday at 3am command
"Clock Driver -> PAST(03:00:00:00s in parameter) -> One Shot-> Button presser-> Projector Power OFF" Be sure to keep in mind - if you load code after 3AM, the projector is going to turn off
By chipmoody@... · #228326 ·
Re: Turning projector off everyday at 3am command
Ok thanks Thanks , Mingo