Re: $$$ for custom simpl# programming for TLS communication
Control Concepts http://www.controlconcepts.net
By jeff · #228331 ·
Re: Tricky Problem with maybe Crosspoints
Thanks for the responses, No i have no backup, i?m not shure if the programmer used crosspoints but it seems like, cause of the naming in the debugger. The RoomButtons triggers Signals like
By piffko@... · #228330 ·
Re: Turning projector off everyday at 3am command
Ok great thanks Thanks , Mingo
By Mingo Manuela · #228329 ·
Re: Turning projector off everyday at 3am command
The WHEN avoids this problem since it¡¯s a pulsed trigger at a specified time rather than the PAST¡¯s latched output. -- Lincoln King-Cliby, CTS, DMC-E-4K/T/D Commercial Market Director Sr. Systems
By Lincoln King-Cliby · #228328 ·
Re: Turning projector off everyday at 3am command
Lol ? ok thanks for the advice Thanks , Mingo
By Mingo Manuela · #228327 ·
Re: Turning projector off everyday at 3am command
"Clock Driver -> PAST(03:00:00:00s in parameter) -> One Shot-> Button presser-> Projector Power OFF" Be sure to keep in mind - if you load code after 3AM, the projector is going to turn off
By chipmoody@... · #228326 ·
Re: Turning projector off everyday at 3am command
Ok thanks Thanks , Mingo
By Mingo Manuela · #228323 ·
Re: $$$ for custom simpl# programming for TLS communication
These guys have an email module with TLS, so maybe they'd be able to help get you pointed in the right direction? I haven't had to do TLS myself, fortunately.
By Stuart Marks · #228324 ·
Re: Turning projector off everyday at 3am command
Pretty sure the error message says to leave the DST blank, because you set it on the processor. Crestron@...> wrote:
By Phil Bridges · #228321 ·
Re: Turning projector off everyday at 3am command
use clock3 symbol clock with no dst parameters Sent from my Samsung Galaxy smartphone.
By coolaiddrinker · #228320 ·
Re: Turning projector off everyday at 3am command
Leave it at 0d. It will pull dst from the processors clock settings Ryan Gray 480-277-7012
By Ryan Gray · #228322 ·
Re: Turning projector off everyday at 3am command
What should I set the dst for the clock driver ? It¡¯s a 3 series processor and it¡¯s giving me an error when I set it to 1d Thanks , Mingo
By Mingo Manuela · #228319 ·
Re: Turning projector off everyday at 3am command
Easiest method Clock Driver -> PAST(03:00:00:00s in parameter) -> One Shot-> Button presser-> Projector Power OFF I tend to use the Alarm Clock Module so the time is user editable.
By Richard Valdez · #228318 ·
Re: Turning projector off everyday at 3am command
WHEN would do the job
By pbukowiec@... · #228325 ·
Turning projector off everyday at 3am command
Guys I¡¯m looking to see what symbol I should use for this ? The client wants me to set up a command to send an off command to a projector everyday at 3am Please help Thx
By Mingo Manuela · #228317 ·
Re: sonos line in Module V1.0
That's correct..
By Peter Jablonicky · #228316 ·
Re: Tricky Problem with maybe Crosspoints
The other thought I had would be ARAM values weren¡¯t moved over to the new CP3, so if they were using something that¡¯s not set now it could cause an issue. Easy enough to get it and write it to
By Caleb Radecky · #228314 ·
Re: Tricky Problem with maybe Crosspoints
"If you took the code from the old CP3 and loaded it to the new one then in theory it should work the same." Unless there was something like a "config.txt" type file that had settings in it that were
By chipmoody@... · #228315 ·
Re: Tricky Problem with maybe Crosspoints
Also, it could be a firmware revision issue, especially if the old CP3 hasn't been touched in a while. Crestron@...> wrote:
By Phil Bridges · #228312 ·
Re: Toolbox Device Discovery Update
Yup its now in the device discovery tool. There¡¯s a radio button at the bottom to select between local and remote. When you choose remote the connection buttons show up at the bottom of the window
By kgoyer@... · #228311 ·