¿ªÔÆÌåÓý

ctrl + shift + ? for shortcuts
© 2025 Groups.io
Date
Re: Modbus
Do you mean the umc and usp are set to 2-series? Wouldn't be too hard to make them 4-series compatible.
By @DizzyEgg · #255480 ·
Re: ITC TS-0300M Delegate System Control
Even with the Settings set to Hex. The Return commands work but there just to many different RX commands the system TX to debugger and waits for the match which is after every 6-8 Mic ON/OFF button
By baker@... · #255479 ·
Re: Thoughts on the IV-SAM-VX2-P?
Thanks for your input Joe! I took the IVC-D (Designer) course yesterday and I must say I concur - we'll definitely be quoting their commissioning service to all our customers for the foreseeable
By igor.pero.bauer@... · #255478 ·
Re: Crestron Go on iOS, any way to keep connection active
Back in the days of the original app we would have an oscillator set at .5s trigger an input. This for some reason would keep the socket alive. I would if this would work for three newer app in this
By Eric Luckart · #255477 ·
Re: New Roku Issues
For issue 3 Maybe try blocking all multicast to the network port of the Roku's. I wonder if it will also fix the issue with 2.
By Eric Luckart · #255476 ·
Re: Modbus
Not an direct answer to your question but I have talk to modbus systems with a Raspberry Pi using the Python's pyModbusTCP library.? Modbus is a pretty simple protocol so I would think it would be
By Steve Kuehn · #255475 ·
New Roku Issues
Just want to let you guys know about several issues with Rokus over the last week. 1) IP control stops working after the most recent firmware update? on newer Roku.? The Roku is still accept
By Steve Kuehn · #255474 ·
Re: Thoughts on the IV-SAM-VX2-P?
You will want to sell professional services, regardless if you take the training before hand, as there are too many variables and the classes don't cover them all.? I did hear Crestron may wave the
By Joe · #255473 ·
Re: eDidio DMX Controller TLS Communication
Are you sending the strings as native bytes or ASCII equivalents? Most of what you have listed are just different forms of notation for the same thing. e.g. cd is equivalent to 205 or 11001101 in
By l_codd · #255472 ·
eDidio DMX Controller TLS Communication
I need to send HEX commands to an eDidio DMX controller. The eDidio DMX controller uses TLS. Can I do this with a TCP or UDP client in SIMPL Windows? I've already tried both, using ports 443 as well
By markcrestrongroup · #255471 ·
Re: viewsonicLDM 136-151 display serial control
After glancing at the manual there doesn't seem to be any config needed to the settings, but there is one blip where they mention "NOTE:?Make sure the Control Board Switch is switched to the left
By mduesing · #255470 ·
Crestron Go on iOS, any way to keep connection active
clients are impatient tap screen, nothing happens, tap again, finally wakes up & back to project select is there any way to keep the connection active? i know battery life will suffer
By mark kaye · #255469 ·
Recommandation for better organise Press/Visibility Digital join
Hi there, How do you guys manange your Press/Visibility Digital Join ? Until now, I simply use the Automatic assigment but I find it can get quite messy. Thanks,
By Anhtu Vu · #255468 ·
VC-4 Tokens on Oracle Virtual Box VM's are behaving oddly
I've noticed that Tokens created on VC-4 installs on Oracle Virtual Box VM's will not display. Instead I get a list of "Key133333333333333333333, Key2,Key3,Key4,Key5,Key6". If I create a new token, it
By Brian Bernas · #255467 ·
Re: Modbus
Hi, In what way are they incompatible? ?The modbus processor module creates the checksum for any modbus command and should work with 4-series just fine. ?You may need to swap the two checksum bytes
By Oliver Hall · #255466 ·
Modbus
Hey Guys I need to control a modbus device with a CP4, but the crestron's modules are not compatible with the series4 Has anyone encountered this problem or have a module that works with series4
By g.michele · #255465 ·
viewsonicLDM 136-151 display serial control
I'm trying to control viewsonic LDM136-151 display via rs-232 from crestron CP4N but have had no luck. The commands are correct and verified. What am I missing?Is there any setting on display that
By smartguyjb818@... · #255464 ·
Re: ITC TS-0300M Delegate System Control
You appear to have debugger set to auto convert string characters to Mixed(HEX/ASCII), you need to set it to HEX so that you can more easily determine what data is being sent back in response to the
By l_codd · #255463 ·
Re: Thoughts on the IV-SAM-VX2-P?
Hello Josh and Bambam, Did you all use the 1Beyond Automate_VX_v1.1 module to control the Automate (PC)? -- Doug G
By Doug G · #255462 ·
Re: ITC TS-0300M Delegate System Control
\xAA\xEE\x08\x00#\x80\x00\x05\x 81 \x00\x00\xEE\xFC ? ?ITC_RX$ The Highlighted keeps changing from 81-88 and then 05y-05z and then 05{, 05}, 05~, 05| etc So the feedback is not triggering my logic
By baker@... · #255461 ·