Re: Roland M-300
Unfortunately im controlling faders, mutes, and aux levels so i was looking for something that included level feedback since the end user will be using our touch panels for control through the crestron to the mixer and an iPad for direct control of the mixer. Thanks for the strings though Steve.
|
Re: Roland M-300
¿ªÔÆÌåÓý
I did a Roland switch a few years back, I didn't have a module since all I was doing was recalling presets, selecting inputs and performing an Auto Take. The protocol was pretty straight forward. Controlled mine over RS232.?
Preset commands were PSE:0; PSE:1 PSE:2, etc.?
Auto Take was ATO:0,TAKE SW1:AUTO TAKE;
Selecting Input 1 to Output 1 was OAV:0,0;
Selecting Input 2 to output 1 was OAV:0,1;
Selecting Input 1 to output 2 was OAV:1,0;
Hope this helps.
Steve
From: [email protected] <[email protected]> on behalf of lordryanshire@... <lordryanshire@...>
Sent: Friday, April 12, 2024 2:14 PM To: [email protected] <[email protected]> Subject: Re: [crestron] Roland M-300 ?
Does anyone have a module for this? I could really use it. Thanks in advance.
|
Re: TCP Client Stopped working
This is a related problem, but not the same... however I think this solution may work for 4 series too. In a 3-series I have the same "Link Lost" problem with the communication with a HomeworksQS system. We install this kind of configuration in almost all of our projects and never happened to us before. What other behaviours I notice are:
1. After uploading program it works fine. 2. If I reboot the system, the Link Lost appears and the communication can't be reestablished until I upload program again. 3. If I connect to the CP3N just before the program starts, when it does the connection is successful and about the time some touch panels reports themselves in the console, I got the Link Lost. 4. We have a very similar problem with CP4N, but in that case, we can reboot the system and it works. 5. It works flawlessly in a 2-series. So, the workaround I found is to wait 60s to establish the communication after the reboot. What I think is happening (at least in the 3-series) is that the system does some initial tasks with the TCP stack that breaks this older kind of connections, so the idea is to wait until everything is done and then connect the third party system. I use a simple delay in Simpl, between the signal that establish the communication and the TCP Client. Try that with your 4 series system, and let us know if it works. clemare |
Re: NVX routing with Crestron Home
The NVX and NAX streams are passing through the next work just fine. Extreme x440 G2 switch.? ? IGMP is doing what it should be doing. The problem is simply the D30 stream location won't change when changing the media source.? (basically switching from one E30s input to another E30's input).? I can go into the D30 gui and manual switch it, just can't get the processor to do it.?
|
Re: NVX routing with Crestron Home
¿ªÔÆÌåÓýIn all likelihood, it is a network issue. NVX and NAX need very specific network setups to pass the video and audio streams. Also, look at the thruput on switches, is critical. We have switched to using the preconfigured Netgear switches from Crestron. No problems after that. ? From: [email protected] <[email protected]> On Behalf Of brandonmadsen25@...
Sent: Friday, April 12, 2024 5:38 AM To: [email protected] Subject: [crestron] NVX routing with Crestron Home ? Long time Crestron commercial dealer here. Building a new home and am currently staging my personal residential system prior to move on. Never tackled a CH system before. Everything is working beautifully except for one little detail with major implications. ?When switching media sources the system does not process it. Running a MC4-r with E30¡¯¡¯s, D30¡¯s and 8zsa. Everything seems to be configured. As needed. ?I can manually switch the routing in the D30 GUi. For some reason though the stream location in the receiver just does not update the stream location when the media source is switched via tsr 310 or CH app. Anyone experience something like this. The only thing that makes sense is the mc4-r isn¡¯t configured correctly so isn¡¯t sending the proper commands but i seriously can¡¯t see where I¡¯ve misconfigured it. My other thought is maybe it¡¯s a network issue. I¡¯m using a cheap firewall while waiting for a new Fortigate 70F to arrive. ?The D30 is subscribed to the multiple E30¡¯s. This is why in the D30 routing table I can manually change the route and the source switches. I just can¡¯t get the control processor to do it ??¡á?. Seriously stumped.? |
Google TV - Where we at now?
Hello all,
I am being asked to recommend the latest, best Google TV device for a client to Chromecast and operate apps similar to Apple TV but for Google ecosphere. What should I tell to get and what has Ip control? I know Nvidia shield and Flirc works but has basic control. @methdeathx where did you get with your project? Thank you Jon |
Re: Developer of Drivers CH
Hi Remo,
toggle quoted message
Show quoted text
Happy to take a look at your request. Can you can contact us off list at support@... and we can take a look? Caleb Caleb Radecky | Manager, Online Products & Services Crestron Silver Certified Programmer | DMC-D-4K | DMC-E-4K ControlWorks Consulting, LLC | Crestron Services Provider | 8228 Mayfield Rd. #6B Rear Cleveland OH 44026 Direct: (+1)440.771.4809 | Cleveland: (+1)440.449.1100 | Boston: (+1)508.695.0188 | DC: (+1)202.381.9070 | London: (+44) 20 4520 4600 -----Original Message-----
From: [email protected] <[email protected]> On Behalf Of Remo Sent: Friday, April 12, 2024 11:04 To: [email protected] Subject: [crestron] Developer of Drivers CH Good morning! We need some extension/driver developers for Crestron Home in Brazil. It would be a driver for an HTTP gateway for a thermostat. We will pay for the service. Can anybody help me? Thanks! Enviado do meu iPhone |
NVX routing with Crestron Home
Long time Crestron commercial dealer here. Building a new home and am currently staging my personal residential system prior to move on. Never tackled a CH system before. Everything is working beautifully except for one little detail with major implications. ?When switching media sources the system does not process it. Running a MC4-r with E30¡¯¡¯s, D30¡¯s and 8zsa. Everything seems to be configured. As needed. ?I can manually switch the routing in the D30 GUi. For some reason though the stream location in the receiver just does not update the stream location when the media source is switched via tsr 310 or CH app. Anyone experience something like this. The only thing that makes sense is the mc4-r isn¡¯t configured correctly so isn¡¯t sending the proper commands but i seriously can¡¯t see where I¡¯ve misconfigured it. My other thought is maybe it¡¯s a network issue. I¡¯m using a cheap firewall while waiting for a new Fortigate 70F to arrive. ?The D30 is subscribed to the multiple E30¡¯s. This is why in the D30 routing table I can manually change the route and the source switches. I just can¡¯t get the control processor to do it ??¡á?. Seriously stumped.?
|
Re: Colorlight Z6 control?
Hello Anewdaytotri,
? Thank you for the info and example code for the Z6!? I've been handed a job using a S6F Planar and the protocol looks similar but the S6F manual only mentions UDP connection.?? I see in your code that there is a subsystem folder for "Datapath".? The system I am working on uses a Datapath VSN400 running WallControl 10.? Do you have experience with controlling those? Thanks again! -- Doug G |
Re: Can't connect to a PRO3 from toolbox
Connecting via USB solved both problems? I now have access to both Pro3's.? I also noticed that when I clear MSG aka ERR via USB the led stays off when I disconnect.
Now I just have to figure out why my weather processor 1.6 and touch panel interface 2.0 isn't working.? Probably a port issue.? The 3 series has much more security then the 2 series and I haven't looked at that yet. |
Re: SIMPL# question
Thank you all for replying.? I wasn't expecting this much feedback but I appreciate all your feedback.
It good to know that even though the Jandy RS adaptor isn't made or supported by Jandy anymore that it may still work.? And IMHO, assuming that it still works, it is really the better solution than using the cloud base solution.? And now there appears that someone is making an after market one. Just do a google search for "jandy rs serial adapter" and you will find the first hit is for one being sold on Amazon.? A little pricey at $890 but it may be a good alternative.? Also search github for Jandy and you will find several open source projects using it. |
Re: SIMPL# question
Oh that iAqualink module really stinks. Would really love to have a module that communicates locally without all the delays. The iAqualink app doesnt seem to have those delays. We had a client that was fed up with it and demanded that we make Jandy fix the API. Yea no thats not how things work sir... Would have been nice if we could load the Jandy app on a TSW panel but cant do that. So we instead used a button on our pool page to flip to the built in browser on the panels and seed the iAqualink web control URL so it opens righ to the controls there which of course work as they should with no delays. A bit of a kludgy workaround but it is good enough for this client.?
I wish the RS interfaces werent impossible to get I would love to keep using those.? |
Re: System Key
Yup I have had the system key change on several PRO3s simply due to power cycles. And some on Init/restore. Completely ridiculous as it can take hours for them to supply you with a new one. In my cases it was a Lutron license so they had no lighting control until whoever lives in the abandoned closet that provides them could get me a new one. Especially the fact that they are now free for those systems that need it, they should be generated by a tool that you can just enter the info and get a new license key.?
There should never be a reason the system key changes. The fact that it can means it can completely break the system at any time for whatever reason.? |
Re: Audio Only source via DM
Also curious about this, as we have 2 dm frames connecting to each other in a lecture hall enviornment (1 at rack, and 1 at teacher station).. The mic is fed via a bnc or dvi card, and runs on the same dm line as the camera feed to go to the teacher station to feed for capture, zoom, teams, etc.?? When switching cameras(there's 2 of them) on the rack dm we loose audio for a few seconds as video in 5&6 switch but audio in 7 always remains the same on output 3. most systems are set up with BNC cards for the audio.? will this stop happening if we switch to DVI? |
Legrand Daker DK+ rs232
I have 2 Legrand daker dk+ in my rack which should have a couple of their sockets toggled on a touch panel, I've looked everywhere and cannot find neither a module nor clear information on the information protocol over rs232 for the device. Has anyone had experience with this and could help me?
|