Hi,

?

i?d like to have a DGE100 just display a single webpage.

I?ve designed a VTPro project consisting of just a single page with a browser embedded app in it.

I?m feeding the desired URL into the app and the webpage is showing up as it should.

I?ve tied the ¡°touchpanel sleep/wake¡± Manager for the DGE100 to a motion detector, so that everytime somebody enters the room, the ¡°wake¡± signal is triggered.

That works as well, the panel is waking up. However, in addition to waking up the panel, the embedded browser opens a new empty tab.

?

Any ideas why this is happening?

?

Thanks,

Thorsten


Re: LCD Toshiba

 

Hello crestronfreak55

I have also tried with this module, but without any result, I send the commands through the module and the monitor answers me FF without making any changes.

I'm starting to think there's something wrong with the monitor.


D3 Multiple loads grouped as one

 

Is there a way to group lighting loads so that D3 shows a single group vs individual loads? Essentially hiding the individual loads and only showing the group for adding to scenes and button presses?
?
for example. I have a project with LED strips in the soffits around a house that I only want to show as a single load but are connected to 4 different modules thought the project.


Re: Custom Edid file?

 

The barco is just the conferencing system running on multiple Intel nucs. (barco nodes) All linked to one another via network.? Nucs all use a Linux back end with the Barco software up front. You use whatever displays, cameras and audio you want. In our case we are using Samsung video wall displays for the meeting participants, then using a mix of Samsung qb series screens and nec screens for remote presenters, content, preview and confidence monitors.

Each display is connected to its own barco node (nuc) and I know the NUC is capable of this res, but the barco os just doesn't allow you to do it.? I have barco telling me if the node sees this res via edid, it will output what we want.?

At this stage extron edid manager looks like it might do what we need.??


Re: Need help controlling old Somfy shades via IR

 

Steve,

Thank you for following up and supplying the documentation you have.
Somfy did respond to me and they also said the high voltage relay interfaces are ESI RP60AU devices.? Based on the documentation you provided they are very similar to the SC1 if not the same thing.

On this job there is a small white box (looks like an old phone jack) that has an IR emitter from Crestron stuck to its receiver and then an RJ11 wire running to the high voltage relays.
We did learn IR codes from the old Crestron program being shot out that IR port but what we learned aren't discrete nor consistent.?

Do you know what IR codes would be used with these devices?

In the Crestron database I did find some Hunter Douglas drivers that control up to 10 different shades by ID (1-10) but I haven't had a chance to test them yet.
Looking in the Crestron database, files section here, RemoteCentral, etc... for ESI or Draper drivers I don't find anything that would control more than 1 shade.

I can post the IR codes we learned in case someone can figure something out that way.
Thanks
Dorel


Re: Custom Edid file?

 

What kind of a display technology does this Barco system use?


Re: Controlling a Crestron HD-MD4X1-4KZ-E with a Extron MLC Plus 84 D touch pad using TCP or UDP

 

I'm currenty working with tech support on the rest API. So far they are not able to switch inputs.


Re: Controlling a Crestron HD-MD4X1-4KZ-E with a Extron MLC Plus 84 D touch pad using TCP or UDP

 

The 4kz api is here:


Re: Controlling a Crestron HD-MD4X1-4KZ-E with a Extron MLC Plus 84 D touch pad using TCP or UDP

 

Are you working with a 4KZ switcher or a 4k? On the 4kz, the top has been shutdown by the engineers because of security flaws. The "conf output 1 route 1" command works on the 4k but not 4kz. Extron tech support used data viewer to send that command and the 4kz rejected it.


Re: Controlling a Crestron HD-MD4X1-4KZ-E with a Extron MLC Plus 84 D touch pad using TCP or UDP

 

¿ªÔÆÌåÓý

Wait so you have the protocol to control that switcher without needing a Crestron controller? Would you mind sharing?

Cheers

Natalie

On Feb 16, 2023, at 2:54 PM, fujiakai@... wrote:

?if you have the unit, test with with Putty from you laptop.

the unit i have works on TCP port 23.


Re: Controlling a Crestron HD-MD4X1-4KZ-E with a Extron MLC Plus 84 D touch pad using TCP or UDP

 

if you have the unit, test with with Putty from you laptop.

the unit i have works on TCP port 23.


Re: LCD Toshiba

 

Hi Juan,

that is strange. I found a driver in the Crestron application market (for the whole TD-E series), dated back to 2016.
This driver as well states that the communication settings have to be set to serial to make serial control possible.
BTW, this driver uses different commands and states that Toshiba Rx pin is pin 2.

Don't give up (by Peter Gabriel) and good luck with the Toshiba.

Best regards
Crestronfreak55


Re: Controlling a Crestron HD-MD4X1-4KZ-E with a Extron MLC Plus 84 D touch pad using TCP or UDP

 

I wish I had a Crestron processor. I'm using extron processor. :(


Re: Controlling a Crestron HD-MD4X1-4KZ-E with a Extron MLC Plus 84 D touch pad using TCP or UDP

 

¿ªÔÆÌåÓý

You add the device to the system configuration in SIMPL windows. Set the ip address for the device in the device settings. Then you load the program to your processor. The device will not register in the ip table. The sync indicators for the inputs is not reliable but control is fairly reliable using the analog joins.

Cheers

Natalie

On Feb 16, 2023, at 11:44 AM, Seadrunk69 <terence.cmb@...> wrote:

?Will it work with UDP? The engineers at Crestron locked tcp port in the 4kz series of switchers.? ?That's what Crestron is telling me.?


Re: Controlling a Crestron HD-MD4X1-4KZ-E with a Extron MLC Plus 84 D touch pad using TCP or UDP

 

Will it work with UDP? The engineers at Crestron locked tcp port in the 4kz series of switchers.? ?That's what Crestron is telling me.?


Re: LCD Toshiba

 

I don?t see any of that in the menu of LCD Toshiba


Re: D3Pro with Cameo Keypads 6Btn Issue #d3pro #cameo

 

So for the CBD keypads that have the 'Lutron button 6 tax' applied, even though the image will force/show the split button 6 only, you can still program button 6 as normal and your 6-btn/non-split keypads will still work fine.
HTH


Re: Custom Edid file?

 

That is interesting.
You can try using Extron EDID Manager to create an EDID file or modify an existing one.
There are lots of options, either get someone that is familiar with EDID or use the try and error methode.

Please keep us updated.
Best regards

Crestronfreak55


Re: LCD Toshiba

 

Hi Juan,

did you enable RS232 in the Menu, Setup, Control and set the proper baudrate?
Afaik, the Toshiba uses Pin 5 for GND, Pin 3 to receive the commands.

Best regards

Crestronfreak55


Re: LCD Toshiba

 

Yes, but not work