?Having converted a number of web xpanels to smartgraphics xpanels they work fine. ? One thing we are currently seeing is the bottom being cut off on the panels when they are run on ultrawide monitors 21:9 aspect. ? On a normal ?16:9 ratio monitors they are displayed fine. ? We've raised this as a case and would be interested if anyone else has found any thing similar.¡°

?

Yes, same here.

?

Cheers, Thorsten

?

Von: [email protected] <[email protected]> Im Auftrag von ScubaSteve
Gesendet: Donnerstag, 14. Januar 2021 08:13
An: [email protected]
Betreff: Re: [crestron] Death of Xpanel 2.0 (Web) Smart Graphic #crestron #xpanel

?

Having converted a number of web xpanels to smartgraphics xpanels they work fine. ? One thing we are currently seeing is the bottom being cut off on the panels when they are run on ultrawide monitors 21:9 aspect. ? On a normal ?16:9 ratio monitors they are displayed fine. ? We've raised this as a case and would be interested if anyone else has found any thing similar.

would prefer a fix rather than moving up a load of buttons on the panel layouts.?


Re: VT - PRO e

 

Download the new vtproe and smartgraphics from the crestron website and it will work.


On Thu, 14 Jan 2021, 13:11 , <thatcat099@...> wrote:
I opened up a project today and got this message " could not load base objects library" so the only thing i see is a white page. Anyone know how to fix this?


VT - PRO e

 

I opened up a project today and got this message " could not load base objects library" so the only thing i see is a white page. Anyone know how to fix this?


Re: Death of Xpanel 2.0 (Web) Smart Graphic #crestron #xpanel

 

Having converted a number of web xpanels to smartgraphics xpanels they work fine. ? One thing we are currently seeing is the bottom being cut off on the panels when they are run on ultrawide monitors 21:9 aspect. ? On a normal ?16:9 ratio monitors they are displayed fine. ? We've raised this as a case and would be interested if anyone else has found any thing similar.

would prefer a fix rather than moving up a load of buttons on the panel layouts.?


Re: Death of Xpanel 2.0 (Web) Smart Graphic #crestron #xpanel

 

The only solution right now is the XPanel Conversion Tool (XCT). If you're planning on keeping a web solution, it's all on the programmers at this time to create an HTML5 solution from scratch.

The conversion launches an Adobe AIR instance, so there's still the software aspect of it. You can't just launch a browser and run an XPanel in there.

--
?
Crestron Service Provider - TBD Enterprises Inc.


Re: Curl formatting

 

I've seen people using my module in combination with some custom S+ modules to parse authentication tokens and send them in subsequent requests. I would normally recommend that all of this be done in a single S# library, but you can get it to work.

--
?
Crestron Service Provider - TBD Enterprises Inc.


Death of Xpanel 2.0 (Web) Smart Graphic #crestron #xpanel

 

Hello,

For those out there who used a lot of xpanels web in their projects. How did you manage to give access to your system since adobe flash is no more working this 2021-01-12? I found some assumptions on the forum but didn't any concrete solutions since the shutdown.

Any HTML5 solutions? (Newest post I found on that it were still Beta last November)

At our company we choosed Web Xpanels for tons of reasons. I tried a Xpanel on the computers and can work as plan B but it will be a major downgrade for maintenances.

?


Re: Compile error after SIMPL update

 
Edited

I cannot speak to DB200 -- I am too chicken.? But I have had a few cases where programs have gotten corrupted in weird ways.?? You might try replacing your processor with a different type and then replacing it back again.? Don't ask me why but I believe that has solved some issues in the past.

Also, it could be your module is conflicting with another module such as a TCP server on the same port.

You also might try using Pre-200 from most of your program and then add a separate program that requires Post-200.? I've run different program versions in different slots I haven't had issues.? Shoot, I even have run SIMPL in one slot and Studio or D3PRO in another slot successfully.


Re: Compile error after SIMPL update

 

I havent tried downgrading the DB since I actually upgraded to support a different module.? I have tried deleting the current module and just readding it, and get the same errors.? As I mentioned I have tried creating a new program from scratch and adding the modules and it compiles just fine.? Super weird.


 

Nice job!!!


 

ckangis, ?Your reply got me thinking. I was finally able to connect to it using a static ip address and the PUF tool. Thanks for the help. It's deployed and working.?


Re: Dolby IMS3000 With Crestron CP3 #cp3 #crestron

 

Hello,

you have to create a RAW in the Dolby device manager. ?

If you would like to contact me, I have developed a full module which will give you total control over the IMS including selecting the SPL, skip +/-, ?reading the the timecode and checking for expired keys. ?You can reach me: Michael <at> block-o-matic <.com>


 

I'm assuming that you have gained control of its IP address? (DHCP or Newly set static)...
The unit has a Web server page, go to a browser and type the IP address (you may have eluded to this in your post).

Have you tried using the USB connection with Toolbox? then use the PUF tool. I'm quite sure that the NSP doesn't support File Trx via FileZilla...
If you can connect with USB, you should probably step up the FW over a few versions, instead of jumping to the latest directly...

This is the latest FW:?CEN-NSP-1 [v1.002.0035, #00B915B6]


Re: Compile error after SIMPL update

 

¿ªÔÆÌåÓý

Have you tried replacing the module with a fresh copy?

?

From: <[email protected]> on behalf of <john@...>
Reply-To: <[email protected]>
Date: Tuesday, January 12, 2021 at 8:42 PM
To: <[email protected]>
Subject: [crestron] Compile error after SIMPL update

?

I am completely stumped on a compile error I am getting after updating to the latest version.? When I have run into similar problems in the past doing a full recompile after deleting the spiswork directory has resolved the issue but this time no luck.? The module I am struggling with is the official denon heos modules, and to add to the mystery if I create a brand new program and add the modules I dont get any compile errors.

Here are the two errors I am struggling with.? Any help is greatly appreciated

ERROR? (LGCMCVT149)? Code\SPlsWork\DenonHEOS_Device_Engine_v7_1_0.cs, Line 91
??????? Code\SPlsWork\DenonHEOS_Device_Engine_v7_1_0.cs] Internal Error (Line 91) - The type 'Crestron.CRPC.MediaPlayer.IMediaPlayer' is defined in an assembly that is not referenced. You must add a reference to assembly 'MediaPlayer, Version=1.0.0.26508, Culture=neutral, PublicKeyToken=null'.
ERROR? (LGCMCVT258) ?
??????? SIMPL+: C# - Compiled with errors for \Code\SPlsWork\DenonHEOS_Device_Engine_v7_1_0.dll


Re: Compile error after SIMPL update

 

Have you tried downgrading to a pre-200 database?


Re: how to remove specific character from string in Crestron simpl+ #crestron

 

I think what you are looking for is a Serial Gather, Serial Substring (Expandable) and a Serial Buffer


 

Hi all, I'm glad I found you after Yahoo!

I bought an Old Stock NIB, CEN-NSP-1. It came with the original release firmware and I've been unable to update its firmware. It displays the embedded web server update ui but nothing happens when I point it to a local file for upgrade. It appears to reject the connection. Toolbox can't connect to it either. Filziila no luck. Has anyone else delt with this issue? Is there any other way to upgrade the firmware other than the embedded UI?

Any help would be appreciated.


Re: Honeywell Wifi Thermostat

 

I looked for this as well and never found anything. Not really sure how one of the largest HVAC solutions does not have a module in Crestron when so many other control platforms support Honeywell.

I was part of a Honeywell integration project for another platform and its quite an undertaking with contracts and API keys from Honeywell to talk to their servers. Very doable, but you really need to have the right team/person doing this. As I recall, all of the control is through their cloud (TC Connect).?


Re: how to remove specific character from string in Crestron simpl+ #crestron

 

¿ªÔÆÌåÓý

I¡¯m not sure you¡¯ve supplied enough details for people to help you.?

The incoming string: is it literally ¡°\x1\x2\x3\x4\x5¡± so 15 characters or is it 5 bytes (0x01, 0x02, 0x03, 0x04, 0x05) ?



On 13 Jan 2021, at 12:45, saravanan.s@... wrote:

?example: serial Input : \x1\x2\x3 \x4\x5 i want output like this serial Output :12345




can any one help as.


Re: Curl formatting

 

thanks for the reply, does the module mentioned above work without going into S# to send a few commands?