Re: Addding E-Control to Simpl Windows.


 

--- In Crestron@..., "mallik arjun" <badri.mallik@...> wrote:

Hi all,

Im Novice to crestron programming. Can any 1 tell me how to add
E-Control to
Simpl windows Program instead of Touch Panel.

Thanks in advance
Regards,
Mallikarjun.


[Non-text portions of this message have been removed]
Easy... In SIMPL
1. Open your SIMPL program
2. Enter configure mode
3. In the device library, open the following folders: "Ethernet
control modules", then "Ethernet Modules (Generic)"
4. Drag the "XPanel" symbol to the ENET slot of your processor (it
should have the default address of 127.0.0.1 and an IP ID of 3)
5. Go back to program mode
6. You will have an XPanel symbol on the ethernet slot of your
processor. If you have an existing touchpanel in the program,
right-click on it and drag it to the Xpanel symbol, when you release
the button, choose "Copy all signals/parameters"
7. Save, compile, load
In VT-Pro-e
1. Open your existing touchpanel file
2. Under file menu choose "Save project as"
3. Choose a different name for the project, for "Panel type" select
"XPANEL"
4. After program saves, click on the root level of the program in the
project view tab of VT-Pro-e, Control + P to open the project properties
5. Choose the "Web" tab, make sure IP ID is 03, and enter the IP
address of your processor under "Control system info"
6. Choose "Compile" tab, from the "Target" list, choose "Browser"
7. Save, compile

Now you need to address the processor, and load your web pages to the
processor, I still use Viewport (I know, I know....) feel free to use
Toolbox. Here's how to do it in Viewport.
1. Connect to your processor via RS-232
2. Under the "functions" menu, choose "Set control system IP information"
3. Enter the IP address
Now you can continue on to load the pages, or you can Alt + D and
change your communication settings to ethernet
4. Under "File transfer" choose "Send web pages"
5. Navigate to folder containing your newly compiled webpages... it
will be "your project name.XWEB"
6. send the file named "Main"

In Internet Explorer:
1. Under the "General" tab: "Tools", "Internet options", "temporary
internet files" choose "Settings", under "check for newer versions of
stored pages" choose "Every visit to the page"
2. Under the "Security" tab: "Trusted sites", under "Sites" enter the
IP address of your processor, uncheck "require server verfication"
3. Close and restart Internet Explorer to make sure all changes take
effect
4. Type in the IP address of your processor into the URL field
5. You should see an e-control logo as you connect to the processor,
the first time you will be prompted to install an add-on that makes
the econtrol work in the browser
6. Test it out

Good luck!

Dan O