I forgot to say that I have always done it using the ControlWorks module with AES and BiPads and would like to incorporate into a SWAMP.
toggle quoted message
Show quoted text
--- In Crestron@..., "John" <ComeAlive@...> wrote:
Would you mind sharing? I am working on a swamp for the first time and need to integrate paging and would like to see how you accomplished this.
--- In Crestron@..., Heath Volmer <hvolmer@> wrote:
What I wound up doing was adding a little bit of logic to my SWAMP module. If the SWAMP's mute feedback isn't in line with what the program thinks it should be, then it quickly puts it back.
Now when my paging logic changes sources, the rooms that are supposed to be muted stay that way. No more feedback. Yay!
Heath
On Aug 5, 2013, at 1:50 PM, Heather Baiman <heather@> wrote:
I just tested using the Sonnex tool - if I mute a zone, and then change the source, it un-mutes. It also un-mutes if I change it to source zero (off)
-----Original Message-----
From: Crestron@... [mailto:Crestron@...] On Behalf Of Heath Volmer
Sent: Monday, August 05, 2013 3:43 PM
To: Crestron@... com
Subject: [Crestron] SWAMP mute
Before I spend a bunch of time hunting down my particular problem, can someone tell me if a SWAMP automatically overrides it's mute when turning on or changing volume? Since it doesn't have the "old" style positive mute line like a PAD8, I think that if the unit is muted and then turns on, it cancels the mute.
Thanks, Heath
------------------------------------
Check out the Files area for useful modules, documents, and drivers.
A contact list of Crestron dealers and programmers can be found in the Database area.
Yahoo! Groups Links
[Non-text portions of this message have been removed]