Open up the module and look at Ana Init S-1.4 (under common logic). Add a delay symbol to delay the init trigger 10 seconds. The problem is within the S+ module where the "entries per page" is read in too fast upon program load.
Matt
toggle quoted message
Show quoted text
--- In Crestron@..., "touchpanelprogrammer" <touchpanelprogrammer@...> wrote:
Anyone find the solution to this problem? I am having the same issue as well. Life size module v3.5, when you pull up the directory, prev page and next page does not work.
--- In Crestron@..., "dimas" <d_jo_han@> wrote:
yes same as me. im using rs232..but next and previous cannot work to display directory. is there any way to solve this?
--- In Crestron@..., "Gregg M" <jets_in_2003@> wrote:
When using Crestrons Lifesize IP Module, I can't get the entire local directory on my panel, and by entire directory, I mean more then the number of entries listed in the bottom paramater. The page next/previous buttons don't seem to do anything and the total number of pages always list 1????????????????????