Re: Slider Crosspoint Issue


 

Or you can use an abuf driven by the digital press join of the slider.

--- In Crestron@..., Nick Mitchell <nick@...> wrote:

I just fixed this issue today. Here is what I did.

Analog equate driven off econnect room id that triggers an abuf for each
room that sets tp's analog fb to vol out of that room.

I have 3 sets of xpoints
TP -> Room -> Device

Hope that helps
Nick




Sent from my eMail.

On May 1, 2013, at 7:17 PM, Jason Andersen <jandersen@...> wrote:



I attempted this several times and I still can't come up with a viable
solution. I am going to do my best to explain this and if anyone wants to
help it would be appreciated.

I want to use a slider for volume and I use crosspoints for the interfaces
and room modules, like I'm suppose too.

When I use the slider on interface A it sends the volume to the room A
module correctly but that slider value is held in memory.

When I change to room B, interface A still holds the slider value and
changes the volume of Room B to whatever the slider was left at.

My brain hurts.





Join [email protected] to automatically receive all group messages.