Dt500D power switch
Trying to remember how to turn on a Dt500D. New battery. When I hold the power switch it comes on says 9.5 volts, says idle and powers off. Jeremy Janzen, CTS
Started by Jeremy Janzen @
YD7001E
I just ordered a YD7001E from Iron Planet Hobbies. There are 6 left as of this moment. I have been waiting quite a while for this to become available. What is the YD7001E? It's a DR5000 that has had the YD9401 added and the DCC and input voltage sensor added. You can read about it on the YaMoRC website. At the moment it seems to be the only way to get a YaMoRC command station apart from waiting for one to appear on eBay.
Started by Oldngrey @
yd6016es problem 11
Hello all well considering when i turned off last night everything was running just fine. all my yd6016es are coupled together with patch cables back to the yd7001 ext in (NO e-Link connection) turned on this morning and my problem started with a yd6016es not working this is module numbers 10 and 11. I have changed the patch cables and it is not that if I unplug module 11 then 10 works if I replug in 11 the green light goes off on 10 and 11 green light comes on but not showing occupies (sensor 174/175) see pic has any one got any ideas please as this has been working great up until I turned on today
Started by Alan Watt @ · Most recent @
Programming Digitrax decoders 8
I have recently bought 2 Digitrax TF4 decoders to control coach lights, I am unable to read or program these. I have iTrain and a YD7001 and can read and program all my other decoders which are ZIMO. I originally thought that I had a bad connection to the rails and so I connected them directly (one at a time) into the programming track output on the YD7001, still they cannot be read. Any help would be much appreciated. Alan
Started by alanmayfield@... @ · Most recent @
yd6016es 2
i think I've asked this before but lost the info how many YD6016ES modules can I couple to my connection to the ext88n on my yd7001 at the moment I have 12 and they all work fine if twelve is the max how can I add more as I don't want to use loconet thanks, Alan
Started by Alan Watt @ · Most recent @
VOLTAGE CHANGE IN THE DCC 4
Good morning from Spain. I apologize for my English, I am using Google Translate. I am waiting for the updated YD7001-E board to arrive and I have seen that the voltage can be changed from the Yamorc application. My idea is that since I have N material, some h0 and Marklin Z, I can use the DCC without having to change the DC current input. Is what I say correct? Thank you very much and wish you a good weekend. Regards, Mario
Started by Mario @ · Most recent @
Locked Digikiejs modules for sale
I have far too many Digikeijs modules, I am ready to put the extra assortment up for sale on Facebook Marketplace, starting May 26, 2024. Thanks, Don
Started by Don Charabin @
Digikeijs to Yamorc conversion...... 2
Hi Guys, I'm running my home layout on Itrain with Digikeijs equipment, apart from the DR5000 which has a YD9401 upgrade. I have been asked to plan a new layout for our club. We would like to use one manufacturers equipment throughout. I have managed to find the Yamorc equivalents for DR4088 = YD6016, DR4018 = YD8116, DR5000 = YD7010. But, I cannot find the equivalent for the DR4024 servo controller. I could use a YD8116 with relays or opto couplers on the output to feed an Arduino that drives the servos and the frog switching. But that seems to be the long way round when there used to be a really nice solution with the DR4024. So, my main question is this, is there another module that will drive servos or do I go to my Arduino? My follow up question is that while some Yamorc dealers are out there, there does not seem to be much in stock. And looking on the Yamorc web site many items are price TBD, delayed, na, cancelled, etc. So if we (the club) decide to go ahead and fit Yamorc equipment, where do I get it from? And bearing in mind I am in New Zealand, the answer could be anywhere in the world. Regards Pete S.
Started by Pete S. @ · Most recent @
TT-DEC feedback with YD6016LN 6
Hi all, I'm trying to use the position received feature of the LDT TT-DEC turntable decoder in conjunction with Rocrail. I have it wired to a YD6016LN using a resistor and diode as per the LDT instructions for the Uhlenbrock 63340 here. I don't seem to be able to get it to work. Is the YD6016LN suitable for this function? The turntable is a Fleischmann 9152, N Gauge. [YD7001, 2 x DR4088LN, YD6016LN]
Started by rog.pearson@... @ · Most recent @
YD7001 and YD7001-E 2
I have just updated to the YD7001 and noticed that there was also a YD7001-E. Did I pick the correct one and I wondered what the difference is? Thanks Alec
Started by Alec Hudson @ · Most recent @
Digikeijs DR5000 failure 17
Good afternoon. It is my first POST in this forum and I am using Google Translate, so I apologize for the translation. My name is Mario and I live in Malaga in Spain. I have been a fan for a long time but only recently got into digital. Speaking with a colleague, they advised me to try to look for a Digikeijs DR5000 and I have not been able to find it. But searching on the internet I found a company in China that provided me with two Dijikeijs power stations without a WIFI module for my partner and me. I give you a photo of the board and a small video with the error it has. I don't know if not having WIFI affects it, but when I turn on electricity, nothing works. The girl who sold it to me in China didn't give me confidence but I wanted to take the risk because I really wanted to have this power plant. I don't know if you can help me with this issue. I have asked in forums in Spain but they can't tell me what the problem could be. I take this opportunity to tell you that my scale is N although I started with H0. Thank you for your help and patience. A greeting from Spain, Mario Link to the video with the error: https://photos.app.goo.gl/sFrztHiDhRVz7qJN9 [img]https://i.ibb.co/rmzwXKG/Imagen-de-Whats-App-2024-04-26-a-las-07-48-30-92c4b305.jpg[/img]
Started by Mario @ · Most recent @
Z21 app 2
Good evening all, just to inform you of an update to the z21 app which prevents you from using multiple functionality with the dr5000 or yd7001.
Started by colinayres1@... @ · Most recent @
#DK50018 configurar dos decos 2 #DK50018
Hola, necesito configurar dos dk500018. Como habria que hacerlo?. Alguien puede ayudarme? gracia Hello, I need to configure two dk500018. How should it be done? Can anybody help me? thank you.
Started by Pedro447 @ · Most recent @
WIRING Digikeijs DR 4103 to Yamorc YD 8116 2
Hi does anyone have or know of wiring diagrams that show how to wire the DR 4103 to a YD 8116? Also if you get the wiring wrong can it damage the YD 8116? thanks John
Started by jw.ramsay@... @ · Most recent @
As of April 25th A New Look of the Forum
Beginning today April 25" 开云体育 has changed the look and fell of the forum. Everything is still there. -- Dennis Cherry Owner/Moderator
Started by Dennis Cherry @
Come on Karst ?? 7
Hi Karst I’ve been hard at work on my second cabinet I like to be neat with wiring and presentation of electronic equipment after all it’s as big a part of the layout and work as the rest It’s just bugging me that the units are marked at 180 to all the previous units as you can see from the picture numbering goes from right to left - just the YD6016LN and ES - I actually like the Blue better than black and the functionality is much better But maybe you could help and send over the graphic so I could re work it by 180 - which I don’t mind doing and sharing Thanks John Sent from my iPhone XR
Started by John Critchley @ · Most recent @
YaMoRC YD6942 2
I have just received these but they don't have printed on the back "To decoder/To signals. How can I determine how to wire them please?
Started by stwdv @ · Most recent @
DR5000 and LCC 8
Just a simple question does the DR5000 support LCC as I am having problems trying to connect a TCS WiFi throttle without using JMRI. Any help greatly appreciated. Alec in UK
Started by Alec Hudson @ · Most recent @
DR5033 Digiboost 14
This was a DR 5033 it’s been running on a large layout with five other DR5033s and a DR5000 for 3 years. Any ideas as to the cause of its demise would be appreciated. thanks George
Started by GMB Rail Systems @ · Most recent @
YaMoRC WiThrottle protocol 7
I am hoping for some advice or feedback with a small issue that is occurring across multiple YD7001 command stations (DR5000 + YD9401 upgrade). Each of the 5 upgraded YD7001 command stations use the version 1.5.5 firmware and Build-68 of the configuration software. For reference, each of the 5 YD7001-equipped layouts incorporate 1 or more dcc circuit breakers in order to split the track work into power districts, such that a short circuit occurring in one district does not shut down the entire layout. In addition, if we are using the Z21 app on our devices, all works well, as does using an on-screen throttle from the PC-based YD7001 config program. By this I mean that the running status (speed + functions + sound) of all locomotives operating in a specific power district is automatically restored following removal of the short circuit (or other track-power interruption) without the need to reset the running status of any one or more specific locomotives by recalling them individually in the throttle stack to do so. However, when used with the TCS UWT-100 or UWT-50e wifi throttles (or any app which interfaces with the internal YaMoRC WiThrottle protocol), we are observing that all locomotives affected by a short circuit need to have their running status reset, recalling each loco in the throttle stack to do so. Interestingly, if we use the TCS products in conjunction with a Digitrax LNWI connected to the YD7001 (instead of using the internal YD9401 WiThrottle protocol) we do not experience this problem of having to reset the locos - their operation is fully restored upon removal of the short circuit, much the same as the Z21 app or an on-screen throttle as mentioned earlier. Additionally, LocoNet-controlled locos (eg with software such as TrainController) also automatically restore loco operations after removal of a short circuit. Please forgive me for this long-winded explanation, but I am concerned there may be something I am doing incorrectly and/or have overlooked in a setting somewhere. Additionally, I am not sure if this issue resides with the TCS throttle products or WiThrottle-based apps, in which case I may need to reach out to these vendors also. I thank the group’s members in anticipation of your advice. With kindest regards to all from Australia, Chris.
Started by Chris Howarth @ · Most recent @