Locked Re: Programming a DR4018 for multiple functions
Jack: how many 2 aspect signals heads and RR Crossings do you want on 1 DR4018? I will post the changes needed for you. Dennis
By Dennis Cherry · #427 ·
Locked Re: Programming a DR4018 for multiple functions
I came across a section on how to set the CV in my search. I think it was in another forum though . I see if I can find it . Iron planet USA is another
By abp <andrew_pink58@...> · #426 ·
Re: DR4018 From Babs
James Good Morning Thank you for your reply. I have just finished testing 40 point Motors in conjuction with a CDU i have now worked out how the 3 way point works. I am going to set up the 4018 and
By Babs <babz1462@...> · #425 ·
Locked Re: Programming a DR4018 for multiple functions
I've watched James' YouTube video on this and it's not clear how one calculates the CV's for multiple functions on the DR4018.? I've also pulled down the worksheet referred to above, but the
By stuart.goble@... · #424 ·
Locked Re: Programming a DR4018 for multiple functions
James from Train Automation UK. Has a demo on YouTube What your asking .
By abp <andrew_pink58@...> · #423 ·
Locked Re: Programming a DR4018 for multiple functions
From what I have read ,I think you can only break up the 4018 into two blocks of four. Please post if you figure out some way of doing that
By James Braxton · #422 ·
Re: DR4018 From Babs
Three way points are two separate points put together as one unit. You just need to find out if the turnout mechanism is, a single or twin coil machine. Once you Know what you have you can then set up
By James Braxton · #421 ·
Re: DR4018 Question
I have to correct my last statement about the preset. I was told previously to try preset 6, I did that and the buzzing persisted. It was not preset 4 that I was told to try. Don Jenkins
By Don Jenkins · #420 ·
Re: DR4018 & DC Question
Here is a quick schematic of the main wiring of my layout. All buss wiring is color coded blue & white starting from the DR5000. All feeders follow the color coding. No issues with operating trains
By Don Jenkins · #419 ·
Re: DR4018 Question
Currently they are in preset 0 per the instructions. I was told to try preset 4 I believe, but that didn't help. Don Jenkins don97jovi@...
By Don Jenkins · #418 ·
Re: DR4018 Question
Kato turnouts are a single coil units , so you should be using Preset # 6
By James Braxton · #417 ·
Re: DR4088 LN CS wiring, twisted or not, ? help a confused newbee! but do i keep them parallel?
Hi SC, I'm new here and too Model railroading as well. This is what I know about wiring. (A) even though they say it's AC it's just a bastardized VDC (B) VDC or VAC you need to make sure that the
By James Braxton · #416 ·
Re: DR4018 & DC Question
Here are a few pictures when this new section was under construction. I pre-wired as much as I could before flipping it over onto its legs. The terminal strip in photo 1 connects the main buss lines
By Don Jenkins · #415 ·
Re: DR4018 & DC Question
Don, If you get a chance can you post some pictures of your wiring. Maybe something that shows the overall shot. I have tried to get one of my Katos to buzz and can¡¯t and haven¡¯t heard of anyone
By Iron Planet Hobbies · #413 ·
Re: DR4018 & DC Question
I don't use a DC power pack to power the DR4018. I have a 12v 3a AC to DC wall wart power supply. The buzzing starts when the DR5000 track power is turned on even without the wall wart plugged in to
By Don Jenkins · #412 ·
Re: DR4018 & DC Question
With that said then you have a 60hz. humm' from your DC power pack. the cheapest way to fix it is to buy a wall wart 12 VDC power supply. Amazon, Ebay or some local store that sells electronics,
By James Braxton · #411 ·
Re: DR4018 & DC Question
I run DCC, so I wouldn't think polarity would be an issue. I do keep a consistent track wiring scheme though. All outside rails are connected to one track power output on the DR5000 and all inside
By Don Jenkins · #410 ·
Re: DR4018 & DC Question
It sounds like a polarity issue. Kato turnouts are power routing units. you may want to switch around the track power wires and see what happens.
By James Braxton · #409 ·
Re: DR4018 & DC Question
The turnouts buzz even if there is no external power supply hooked to the DR4018. As soon as the DR5000 power is turned on the buzzing starts. The only way the buzzing stops is if I jumper from the
By Don Jenkins · #408 ·
Re: DR4018 & DC Question
OK, I was not clear on what terminals. Was interested in the terminals on the Controlmaster 20. Have you tried a different power source to see if the correct the buzzing?
By Dennis Cherry · #407 ·