Welcome to the YaMoRC/Digikeijs English Forum
?
This Table of contents provides information about the YaMoRC and Digikeijs products in US English and JMRI.
Click on the "Read More" to see all the information.
Legal notice:
All instructions are written to the best of our knowledge and belief of the respective authors.
Nevertheless, no liability for any errors or omission in the Documentation is intentional!
?
General:
The Main website of the manufacturers YaMoRC and Digikeijs can be reached via the following link:
- Link to the
- YaMoRC Support for Documents. TBD
- Link to the Digikeijs Firmware:?The latest firmware for each product will be in its respect file directory if we have the latest firmware.
- This is an archive that was made and will have documents in other languages. Check before you download.
?
US Dealers:
- for YaMoRC and Digikeijs Products.
Click on any RED Model number below, it will send you to the files page for that device.
English Only Manuals and Photos, etc can be found on this Forum and elsewhere:
Central Station:
- DR5000 The first Command Station with all conceivable connection sockets and LED status lights, USB, LAN & WLAN
- Detailed Tutorial - Rudy's Model Railway Videos on DR5000
Booster:
- DR5033 3 amp Booster works with many different Command Stations
Switch and Servo Modules:
- DK50018 16 Channel Bluetooth accessory and switching decoder
- DR4018 16 Channel Multi-Protocol Switching Decoder
- Manual: DR4018 Advanced V1.2
- Video Series for the DR4018 or DK50018 on Preset 1 in JMRI to invert the outputs for LED Signals.
-
- Guide for Testing the DR4018/DK50018 for proper Preset Configuration.?
- DR4024 4-output multi-protocol servo decoder with 4 additional switching outputs
?
Feedback Modules:
- ?DR4088CS & CS-GND 16-input feedback module (S88)
?
- ?DR4088LN-CS, LN-GND & LN-OPTO 16-input feedback module (LocoNet)
-
?
- ?DR4088RB-CS & RB-OPTO 16-input feedback module (R-Bus)
?
- ?DR5088RC 16-input feedback module with RailCom (LocoNet)
?
Reverse Loop Module
- ? DR5013
- Video :?
Turntable Module
- ??? DR5052
?
Other Equipment
- ??? DR4050 DigiLEDs RGB Model Train Light Control
?
- ??? DR5022 DigiControl for the control of 2 trains via a swivel
?
- ??? DR5039 LocoNet-B to CDE
?
- ??? DR5097 DigiNetHub 10x LocoNet Hub
?
- ??? DR5098 DigiNetHub 10x X-Bus Hub
?
- ??? DR5099 DigiNetHub 5x X-Bus Hub & 5x LocoNet Hub
Software
- JMRI
?
- RocRail
-
- ITrain
- Train Controller
- Perecli RRA (Railroad Automation)
- ?
- ?
- ?
- ?
- ?
-
- AnyRail:
Throttles:
- Document showing the Apps that work with JMRI and DR5000 with download links.
- Roco WLANmaus Throttle Setup For The Digikeijs DR5000
- Test of the Proto-Throttle with the Digikeijs DR5000
- RtDrive Lenz With The Digikeijs DR5000
- ESU Mobile Control II Throttle With The Digikeijs DR5000
- DigiTrainsPro (Android Phone) DR5000 Setup (Now a monthly fee of 5 Eros for this version)
- Z21 App for Apple or Android Phones.?
?
Other Features:
- ?
?
?
?
Re: Resistor for block detection, best size?
So let me ask a dumb question, as I’ve only set up sample blocks with DR5088RC and have seen the RC ids show up in my blocks but don’t actually detect any current.
The question:
Why do I care
By
Chadbag
·
#4826
·
|
Re: upgraded DR5000 to YD7001 throttle issue
Yes, YaMoRC's karst.drenth posted in the thread.
By
Oldngrey
·
#4825
·
|
Re: Programmer Busy reading CVs with Ops mode over Railcom with YD9401
I tried 2, 3 and 4. With 4 I get some (fewer) Programmer busy messages. With 2 and 3, I don't get Programmer busy, but I do see pauses., fewer with 2 than 3. It seems that 3 is the best setting for
By
Scott Walton
·
#4824
·
|
Thread exception attempting to run YD9401
Shortly after I open the app, I get this exception:
This is on Windows 11. All attempts to r]use the app result in a "click" and no response. When I click on "OK", the app closes. The same result if
By
Scott Walton
·
#4823
·
|
Re: upgraded DR5000 to YD7001 throttle issue
Thanks for the thread, it appears there was no resolution to the issue. I figured quickly that after acquiring the locomotive I was able to use the 602D wirelessly for control. Seems like a conflict
By
David Betz
·
#4822
·
|
Re: Can the YD7001 be used for setting CVs on accessories ?
Nope, that is not unclear ;) As of LocoNet specs, RailSync ( which drives the boosters ) must be a carbon-copy of what the commandstation sends to the track. And so it is done by our command stations,
By
karst.drenth
·
#4821
·
|
Re: Programmer Busy reading CVs with Ops mode over Railcom with YD9401
Lower this setting: (POM packet repeat count)
... until it completely stops reading. My experience is that 2 or 3 are a good value.
Unfortunately JMRI does *not* handle "Busy" with a retry of the
By
karst.drenth
·
#4820
·
|
Re: Programmer Busy reading CVs with Ops mode over Railcom with YD9401
Scott,
There are many factors that can impact the speed of reading when using PoM, amongst them being how busy the track is i.e. how many other locos are present, with special consideration as to
By
Iain Morrison
·
#4819
·
|
Re: upgraded DR5000 to YD7001 throttle issue
I think this is the same as previously discussed. A search in this forum for DT602D found this thread:
/g/YaMoRC-Digikeijs/topic/102227767#msg3973
I don't think the DR5000 was
By
Oldngrey
·
#4818
·
|
Programmer Busy reading CVs with Ops mode over Railcom with YD9401
I have a DR5000 which has been upgraded to a YD9401. When I use DecoderPro with Programming on Main to read Read All Cvs, I get many "Programmer Busy" responses. The LocoNet log shows that the Write
By
Scott Walton
·
#4817
·
|
Re: Can the YD7001 be used for setting CVs on accessories ?
Jay,
Just select the Loco PoM or Accessory PoM radio button on the YD7001 programming interface, enter the address for the device, the CV number and then the value.
You will need to try both
By
Iain Morrison
·
#4816
·
|
Can the YD7001 be used for setting CVs on accessories ?
Hi
We will shortly have 6 circuit breakers installed on our club layout.? I am giving each of them a unique accessory address before they are installed.
I am trying to determine if the YD7001 can
By
Jay Lennox
·
#4815
·
|
Re: Resistor for block detection, best size?
Whist iTrain can calculate the train length placing resisting axles at the
back of trains lets iTrain see the back of the train - especially useful
for reversing or if you lose part of the train
By
Iain Morrison
·
#4814
·
|
Re: Resistor for block detection, best size?
Thanks for that Iain.? Would you add the resistors to wagons when using iTrain as the length of the loco/wagon combination is calculated by iTrain?
By
alanmayfield@...
·
#4813
·
|
Re: Resistor for block detection, best size?
The resistor axles have no impact upon Railcom and simply provide occupancy
for the wagon.
FYI Railcom has nothing to do with occupancy, it is simply reporting the
details from the decoder. The
By
Iain Morrison
·
#4812
·
|
Re: Resistor for block detection, best size?
I use iTrain with DR5088RC but don't have axle detection for wagons.? I can understand how resistors would work for current detection, I don't understand how they work with Railcom as resistors are
By
alanmayfield@...
·
#4811
·
|
upgraded DR5000 to YD7001 throttle issue
I recently upgraded my DR5000 to a YD7001. Everything went according to plan and I now have WIFI working. I use Digitrax DT602D throttles and a Digitrax UR93 radio. The problem is that I now have to
By
David Betz
·
#4810
·
|
Re: Mounting the YD6940
Don't discount hot glue ht glue. It's super easy & I use it everywhere with success.
By
Ray Jorgenson
·
#4809
·
|
Re: Mounting the YD6940
Thanks for the suggestion. I dunno why I didn't think of zip ties on mounts before.
On order now.
By
Oldngrey
·
#4808
·
|
Re: Mounting the YD6940
I use the small zip tie mounts that I screw to the bottom of the baseboards and then use zip ties to hold them up. The mounts come with sticky tape but I use the screw hole. Mike
--
Mike's Deep Run
By
Mike's DeepRun RR
·
#4807
·
|