Welcome to the YaMoRC/Digikeijs English Forum
?
This Table of contents provides information about the YaMoRC and Digikeijs products in US English and JMRI.
Click on the "Read More" to see all the information.
Legal notice:
All instructions are written to the best of our knowledge and belief of the respective authors.
Nevertheless, no liability for any errors or omission in the Documentation is intentional!
?
General:
The Main website of the manufacturers YaMoRC and Digikeijs can be reached via the following link:
- Link to the
- YaMoRC Support for Documents. TBD
- Link to the Digikeijs Firmware:?The latest firmware for each product will be in its respect file directory if we have the latest firmware.
- This is an archive that was made and will have documents in other languages. Check before you download.
?
US Dealers:
- for YaMoRC and Digikeijs Products.
Click on any RED Model number below, it will send you to the files page for that device.
English Only Manuals and Photos, etc can be found on this Forum and elsewhere:
Central Station:
- DR5000 The first Command Station with all conceivable connection sockets and LED status lights, USB, LAN & WLAN
- Detailed Tutorial - Rudy's Model Railway Videos on DR5000
Booster:
- DR5033 3 amp Booster works with many different Command Stations
Switch and Servo Modules:
- DK50018 16 Channel Bluetooth accessory and switching decoder
- DR4018 16 Channel Multi-Protocol Switching Decoder
- Manual: DR4018 Advanced V1.2
- Video Series for the DR4018 or DK50018 on Preset 1 in JMRI to invert the outputs for LED Signals.
-
- Guide for Testing the DR4018/DK50018 for proper Preset Configuration.?
- DR4024 4-output multi-protocol servo decoder with 4 additional switching outputs
?
Feedback Modules:
- ?DR4088CS & CS-GND 16-input feedback module (S88)
?
- ?DR4088LN-CS, LN-GND & LN-OPTO 16-input feedback module (LocoNet)
-
?
- ?DR4088RB-CS & RB-OPTO 16-input feedback module (R-Bus)
?
- ?DR5088RC 16-input feedback module with RailCom (LocoNet)
?
Reverse Loop Module
- ? DR5013
- Video :?
Turntable Module
- ??? DR5052
?
Other Equipment
- ??? DR4050 DigiLEDs RGB Model Train Light Control
?
- ??? DR5022 DigiControl for the control of 2 trains via a swivel
?
- ??? DR5039 LocoNet-B to CDE
?
- ??? DR5097 DigiNetHub 10x LocoNet Hub
?
- ??? DR5098 DigiNetHub 10x X-Bus Hub
?
- ??? DR5099 DigiNetHub 5x X-Bus Hub & 5x LocoNet Hub
Software
- JMRI
?
- RocRail
-
- ITrain
- Train Controller
- Perecli RRA (Railroad Automation)
- ?
- ?
- ?
- ?
- ?
-
- AnyRail:
Throttles:
- Document showing the Apps that work with JMRI and DR5000 with download links.
- Roco WLANmaus Throttle Setup For The Digikeijs DR5000
- Test of the Proto-Throttle with the Digikeijs DR5000
- RtDrive Lenz With The Digikeijs DR5000
- ESU Mobile Control II Throttle With The Digikeijs DR5000
- DigiTrainsPro (Android Phone) DR5000 Setup (Now a monthly fee of 5 Eros for this version)
- Z21 App for Apple or Android Phones.?
?
Other Features:
- ?
?
?
?
Re: DR5000 & Cobalt Problems
They would if you placed them in a bit of track that was going back through
a detector - put them in the feed side of the power and they should be ok.
You can put them anywhere, doesn’t have to be
By
Iain Morrison
·
#4630
·
|
Re: DR5000 & Cobalt Problems
I've tried them bus suppressors and they gave me false occupancies
[email protected]> wrote:
By
Alan Watt
·
#4629
·
|
Re: DR5000 & Cobalt Problems
John,
This is still expensive for what it actually is but more realistic given it includes postage charges
DCC Power Bus Terminator Snubber Filter Kit Pair | eBay
By
Iain Morrison
·
#4628
·
|
Re: Lodi-con with YD7001 via Z21 protocol - bug?
I find this response for Lodi rather surprising given that the Z21 protocol
is an openly published document and has been used by many other companies
to develop items and not of them seem to have an
By
Iain Morrison
·
#4627
·
|
Re: DR5000 & Cobalt Problems
But other things take more than 2mins effort to make for yourself.
Many Thanks
Iain Morrison
https://wimorrison.com/
[email protected]> wrote:
By
Iain Morrison
·
#4626
·
|
Re: DR5000 & Cobalt Problems
Adam, where did you buy the self assemble bus suppressor kits?
It maybe helpful for others if they need them?
Thanks John
XR
By
John Critchley
·
#4625
·
|
Re: DR5000 & Cobalt Problems
I have 20 cobalt IPs and have had the same issue. ?Didn’t think DCC concepts would be prepared to replace them all. ?Whenever I spoke to them about the dr5000 it felt like it was some suspicious
By
Adam Eddy
·
#4624
·
|
Lodi-con with YD7001 via Z21 protocol - bug?
I have the very nice Lodi-Con Controller ( Das LoDi-Con - Lokstoredigital ( https://lokstoredigital.jimdoweb.com/lodi-con/ ) )....that was advertised to work with any Z21 protocol station. The unit
By
Reded
·
#4623
·
|
Re: DR5000 & Cobalt Problems
Yup...But you could say that about just about anything :-)
By
Reded
·
#4622
·
|
Re: DR5000 & Cobalt Problems
Bloomin ‘eck - ?10 for components that would cost 20p!!
Sent: 25 November 2024 22:26
To: [email protected]
Subject: Re: DR5000 & Cobalt Problems
[Edited Message Follows]
I had the
By
Iain Morrison
·
#4621
·
|
Re: DR5000 & Cobalt Problems
I had the same issue and they replaced 12 (out of 30) of mine. I use Railcom so turning it off was not an option. I added these about a year ago and the issue cleared up ! Bus Suppressors/Terminators
By
Reded
·
#4620
·
Edited
|
Re: DR5000 & Cobalt Problems
no dont use railcom its always turned off
its the first thing dcc concepts asked
By
Alan Watt
·
#4619
·
|
Re: DR5000 & Cobalt Problems
Alan,
Do you use Railcom on your layout? If not then switch it off in the YD7001. IP Digitals often don’t play well with Railcom
Iain
Sent: 25 November 2024 17:21
To:
By
Iain Morrison
·
#4618
·
|
DR5000 & Cobalt Problems
Hello Forum
some time ago I had problems only with Cobalt ipdigitals connected to the old DR5000 some cobalts would lose or change their address for no reason.
I had many a chat with dcc concepts and
By
Alan Watt
·
#4617
·
|
Re: Kato Turnouts and YD8008s
Hundreds of YD8008 are used in this way, never had complaints about "Humming"
Best thing to do however would be to use a SMPS of about 15-18VDC.
Greets,
Karst
By
karst.drenth
·
#4616
·
|
Re: Kato Turnouts and YD8008s
It sounds like the 50018 was not set up correctly and you were using it as an On/Off switch rather than setting the correct option for solenoid motors which would explain why the motors were buzzing
By
Iain Morrison
·
#4615
·
|
Re: Kato Turnouts and YD8008s
Hi Dennis,
Since we moved, we no longer have the layout that used Digikeijs. ?I do not remember setting CV47. ?We used the Digikeijs app to set up the switch decoders.
At this time, we are just
By
@Kysouthern
·
#4614
·
|
Re: Kato Turnouts and YD8008s
What CV47 number do you have set on the DR4018 or DK50018?
--
Dennis Cherry
Owner/Moderator
By
Dennis Cherry
·
#4613
·
|
Kato Turnouts and YD8008s
We used the Digikiejs DR5000 and DK50018s along with the DR4101s to operate an N Scale layout with Kato track and turnouts. ?They operated well, but the switches had a humming sound when track power
By
@Kysouthern
·
#4612
·
|
Re: YaMoRC-Digikeijis Network Detection
On Thu, Oct 24, 2024 at 07:04 PM, karst.drenth wrote:
>
> Thanks Karst. I'll get to work!.
By
Roy Endersby
·
#4611
·
|