开云体育

ctrl + shift + ? for shortcuts
© 2025 开云体育
Re: DR-5013 set-up and Rocrail
Thanks so much Iain for your input I modified my setting according to your suggestions with no success. Obviously you are correct it is indeed the CS that is detecting the short. My question is
By botter · #3976 ·
Re: DR-5013 set-up and Rocrail
I have a DR5013 used in the way you suggest (but with a Z21 and iTrain) and suffer none of the issues you describe. For the record and correctness it is not RocRail that is detecting the short
By Iain Morrison · #3975 ·
DR-5013 set-up and Rocrail
I'm using the DR5013 short detection capabilities to manage a "simple" reverse loop .? Following? the manual's instructions? I didn't modify any of the factory settings (no value assigned to S0-S3
By botter · #3974 ·
Re: Difficulty acquiring locomotives with a Duplex throttle
I just upgraded to the UR93 as the UR92 had difficulties acquiring locos with the YD7001. Actually the main problem wasn't acquiring locos as much as it was consisting them. Now that I have upgraded
Re: Unable to operate a flashing LED with DR4018
For info 2 x 220 micro farads worked, no buzz. I still don’t understand why a standard LED works from the output of the DR 4018 but a flashing one doesn’t. Pity because it means lots of extra
By RobinP · #3972 ·
Re: Unable to operate a flashing LED with DR4018
Thanks Iain. I am using a separate power supply which I thought was stabilised but probably isn’t. I will experiment with a small capacitor and see if that works. Robin
By RobinP · #3971 ·
Re: Unable to operate a flashing LED with DR4018
Robin How are you powering the DR4018? If you are using DCC then you will have rectified DCC as the output and what you are hearing is the ripple from that rectified voltage. A small capacitor
By Iain Morrison · #3970 ·
Re: Unable to operate a flashing LED with DR4018
I posted a question earlier regarding the DR4018 not being able to operate a tiny LED with built in flasher, it operates a normal LED with no problems. The recommendation was to use a small relay
By RobinP · #3969 ·
Re: Issues with DR5033s with upgraded DR5000 w/YD9401 module
Except for 1 thing. Karst, the developer, emphatically states below that you should not be using common power supplies for HBridge components. I know people have stated that it works and it obviously
By Oldngrey · #3968 ·
Re: Issues with DR5033s with upgraded DR5000 w/YD9401 module
Update! While working with Thomas Ose of?OMS(re)models.com, who is very familiar with this system and a friend of mine. We have it resolved. I had to reverse wiring on the 4 5033s and configure the
By Jim Tatum · #3967 ·
Re: Issues with DR5033s with upgraded DR5000 w/YD9401 module
Jim, Hover your mouse over the IB box. It says "The ID with which the YD7001 reports itself in Slot 0". Sounds like I would never need to know it unless I was doing logging analysis.
By Oldngrey · #3966 ·
Re: DR5033 with Lenz DCC
Adam, Thanks for the idea/solution.? I'm familiar Arduinos.? I use them to drive my servo controlled switch machines.? To finish it, Ryan fro Iron Planet Hobbies offered to reprogram the DR5033s
By Mike L <mjlinden58@...> · #3965 ·
Re: Issues with DR5033s with upgraded DR5000 w/YD9401 module
Thanks Oldngrey, I found that one of the DR5033 was not set properly and matched it to the other 3 units. Looking at the Expert tab, I am wondering what this setting should be? IB or YD? And what
By Jim Tatum · #3964 ·
Re: DR5033 with Lenz DCC
I have a DR5000 with 2 DR5033 running 2 regions and the DR5000 running DCC accessories such as my DCC concepts Digital IP point motors - which I believe are pretty much like a tortoise but with a DCC
By Adam Eddy · #3963 ·
Re: Issues with DR5033s with upgraded DR5000 w/YD9401 module
Jim, According to the DR5033 manual I thougt common ground wiring referred to using a common track across all boosters not common power supplies. You can configure the DR5033 from the YD7001. Just
Re: DR5033 with Lenz DCC
Karst, Thank you once again for the response. ?I understand that you do not like the auto reverse feature of the DR5033 however the Digikejis documentation says that the DR5033 has that feature.
By Mike L <mjlinden58@...> · #3961 ·
Re: Issues with DR5033s with upgraded DR5000 w/YD9401 module
I have a converted DR5000 with 4 DR5033 connected to a single regulated power supply and this has shown no problems before or after the conversion. I have all the DR5033 fuse protected but then that
By tmose2012 · #3960 ·
Re: Issues with DR5033s with upgraded DR5000 w/YD9401 module
Thanks to all who responded and I greatly appreciate the feedback and recommendations. To be honest I researched the Digikeijs DR5000 and DR5033s, I did not find any information stating that it was
Re: Issues with DR5033s with upgraded DR5000 w/YD9401 module
For YaMoRC devices with HBridge it is not !! Every HBridge needs it's own double Isolated Switch-Mode powersupply. !!! Not complying leads to Common Ground wiring, which is NOT supported and might
By karst.drenth · #3958 ·
Re: Purging locos YD7001
I could be wrong, but… I thought that release would remove the locomotives from the slot they were occupying. Whereas Dispatch would maintain the slot, allowing someone else to pickup the loco or
By Heath @ Human[c]ity Junction · #3957 ·