Welcome to the YaMoRC/Digikeijs English Forum
?
This Table of contents provides information about the YaMoRC and Digikeijs products in US English and JMRI.
Click on the "Read More" to see all the information.
Legal notice:
All instructions are written to the best of our knowledge and belief of the respective authors.
Nevertheless, no liability for any errors or omission in the Documentation is intentional!
?
General:
The Main website of the manufacturers YaMoRC and Digikeijs can be reached via the following link:
- Link to the
- YaMoRC Support for Documents. TBD
- Link to the Digikeijs Firmware:?The latest firmware for each product will be in its respect file directory if we have the latest firmware.
- This is an archive that was made and will have documents in other languages. Check before you download.
?
US Dealers:
- for YaMoRC and Digikeijs Products.
Click on any RED Model number below, it will send you to the files page for that device.
English Only Manuals and Photos, etc can be found on this Forum and elsewhere:
Central Station:
- DR5000 The first Command Station with all conceivable connection sockets and LED status lights, USB, LAN & WLAN
- Detailed Tutorial - Rudy's Model Railway Videos on DR5000
Booster:
- DR5033 3 amp Booster works with many different Command Stations
Switch and Servo Modules:
- DK50018 16 Channel Bluetooth accessory and switching decoder
- DR4018 16 Channel Multi-Protocol Switching Decoder
- Manual: DR4018 Advanced V1.2
- Video Series for the DR4018 or DK50018 on Preset 1 in JMRI to invert the outputs for LED Signals.
-
- Guide for Testing the DR4018/DK50018 for proper Preset Configuration.?
- DR4024 4-output multi-protocol servo decoder with 4 additional switching outputs
?
Feedback Modules:
- ?DR4088CS & CS-GND 16-input feedback module (S88)
?
- ?DR4088LN-CS, LN-GND & LN-OPTO 16-input feedback module (LocoNet)
-
?
- ?DR4088RB-CS & RB-OPTO 16-input feedback module (R-Bus)
?
- ?DR5088RC 16-input feedback module with RailCom (LocoNet)
?
Reverse Loop Module
- ? DR5013
- Video :?
Turntable Module
- ??? DR5052
?
Other Equipment
- ??? DR4050 DigiLEDs RGB Model Train Light Control
?
- ??? DR5022 DigiControl for the control of 2 trains via a swivel
?
- ??? DR5039 LocoNet-B to CDE
?
- ??? DR5097 DigiNetHub 10x LocoNet Hub
?
- ??? DR5098 DigiNetHub 10x X-Bus Hub
?
- ??? DR5099 DigiNetHub 5x X-Bus Hub & 5x LocoNet Hub
Software
- JMRI
?
- RocRail
-
- ITrain
- Train Controller
- Perecli RRA (Railroad Automation)
- ?
- ?
- ?
- ?
- ?
-
- AnyRail:
Throttles:
- Document showing the Apps that work with JMRI and DR5000 with download links.
- Roco WLANmaus Throttle Setup For The Digikeijs DR5000
- Test of the Proto-Throttle with the Digikeijs DR5000
- RtDrive Lenz With The Digikeijs DR5000
- ESU Mobile Control II Throttle With The Digikeijs DR5000
- DigiTrainsPro (Android Phone) DR5000 Setup (Now a monthly fee of 5 Eros for this version)
- Z21 App for Apple or Android Phones.?
?
Other Features:
- ?
?
?
?
Re: DR5033 with Lenz DCC
I have a DR5000 with 2 DR5033 running 2 regions and the DR5000 running DCC accessories such as my DCC concepts Digital IP point motors - which I believe are pretty much like a tortoise but with a DCC
By
Adam Eddy
·
#3963
·
|
Re: Issues with DR5033s with upgraded DR5000 w/YD9401 module
Jim,
According to the DR5033 manual
I thougt common ground wiring referred to using a common track across all boosters not common power supplies.
You can configure the DR5033 from the YD7001. Just
By
Oldngrey
·
#3962
·
Edited
|
Re: DR5033 with Lenz DCC
Karst,
Thank you once again for the response. ?I understand that you do not like the auto reverse feature of the DR5033 however the Digikejis documentation says that the DR5033 has that feature.
By
Mike L <mjlinden58@...>
·
#3961
·
|
Re: Issues with DR5033s with upgraded DR5000 w/YD9401 module
I have a converted DR5000 with 4 DR5033 connected to a single regulated
power supply and this has shown no problems before or after the
conversion. I have all the DR5033 fuse protected but then that
By
tmose2012
·
#3960
·
|
Re: Issues with DR5033s with upgraded DR5000 w/YD9401 module
Thanks to all who responded and I greatly appreciate the feedback and recommendations. To be honest I researched the Digikeijs DR5000 and DR5033s, I did not find any information stating that it was
By
Jim Tatum
·
#3959
·
Edited
|
Re: Issues with DR5033s with upgraded DR5000 w/YD9401 module
For YaMoRC devices with HBridge it is not !! Every HBridge needs it's own double Isolated Switch-Mode powersupply. !!!
Not complying leads to Common Ground wiring, which is NOT supported and might
By
karst.drenth
·
#3958
·
|
Re: Purging locos YD7001
I could be wrong, but¡
I thought that release would remove the locomotives from the slot they were occupying.
Whereas Dispatch would maintain the slot, allowing someone else to pickup the loco or
By
Heath @ Human[c]ity Junction
·
#3957
·
|
Re: Purging locos YD7001
Jay,
Thank you for the clarification.
I use similar devices to you with WiThrottle, Engine Driver, WLANMaus but also the Z21 App on iPhone or Android.
I have turned off the YD7001 Wifi and use a
By
Brian A
·
#3956
·
|
Re: Issues with DR5033s with upgraded DR5000 w/YD9401 module
After I updated to the YD7001 I accidently crossed the track A/B wires on the YD7001 to where they were no longer common with the DR5033's. Swapping the wires on the YD7001 cured the short circuit I
By
Mike's DeepRun RR
·
#3955
·
|
Re: Issues with DR5033s with upgraded DR5000 w/YD9401 module
Moving back on topic in a moment:
I am moving from a Digitrax system to the YaMoRC/Digikeijs world with a few DR5033's and a YD7001. I got them a few months ago when YaMoRC stock was briefly available
By
Oldngrey
·
#3954
·
|
Re: Purging locos YD7001
Brian
I am going to take a shot at clarifying what Karst was saying about Release .....
In the WiThrottle protocol there are two commands that are supported - Release and Dispatch.? What they do is
By
Jay Lennox
·
#3953
·
|
Re: Purging locos YD7001
Hi Brian,
Well I actually meant thet releasing (purging) a refresh-slot is the responsibility of the controlling party. Not some kind of "garbage-collection" in the controll *ed* device, just because
By
karst.drenth
·
#3952
·
|
Re: Programming #YD8116 with #DR5000 via CVs - "old way"
#DR5000
#YD8116
Hi,
Ah... you seem to be a bit impatient... Posting a ticket last night ;) Signing with your name is also considered polite around here.
Your question:
No you cannot. Our decoders do not have CV's
By
karst.drenth
·
#3951
·
|
Re: Issues with DR5033s with upgraded DR5000 w/YD9401 module
It think I know some one Vienna Austria that has a couple for sale.
Richard
By
Richard Trilling
·
#3950
·
|
Re: Issues with DR5033s with upgraded DR5000 w/YD9401 module
Jim,
I will be following along as I am building a layout that has a YD7001 and a DR5033.
Have you tried adjusting the speed at which the YD7001 triggers a short? It might just be reacting faster
By
Heath @ Human[c]ity Junction
·
#3949
·
|
Re: Purging locos YD7001
Karst,
Thanks for your response, I understand you may not implement the functionality.
The Roco Z21 has implemented automatic release/purging of locos that have been stopped and are no longer
By
Brian A
·
#3948
·
|
Re: Issues with DR5033s with upgraded DR5000 w/YD9401 module
Where can you get a YD9401 in the US? Iron Planet is out of stock. Are they the only dealer?
Thank,
-bruce
Bruce G Alcock | OK N-Rail | 405-381-4314<tel:405-381-4314> |
By
Bruce Alcock
·
#3947
·
|
Issues with DR5033s with upgraded DR5000 w/YD9401 module
I have upgraded my DR5000 with the YD9401 module and followed all instructions as posted in this group and the the instruction found on the YaMorCo website. I have 2 issues at present.
1. The YD7001
By
Jim Tatum
·
#3946
·
Edited
|
Re: DR5033 with Lenz DCC
Well Mike,
As a "first" the DR5033 is NOT a reverse loop controller :O? That it worked in the first Loop, is based on pure luck...
As a matter of fact, people using the DR5033 in this way, caused a
By
karst.drenth
·
#3944
·
|
Re: Purging locos YD7001
Hi Brian,
Well, all you ask or expect to be present in the YD7001 is not there, and will not be there...
Why ? Well, simple: Your WiFiTrax system is obviously not capable of handling a standard
By
karst.drenth
·
#3943
·
|