Re: Feedback Sensors
Hi, LocoNet Feedback-Address-Space is 4096 addresses large. That means in theory 42 of these units.... ( with 96 contacts each ) But please note: One should prevent getting the ES-Link buscables
By karst.drenth · #3915 ·
Re: Feedback Sensors
Hi Karst, does that mean that I can have several of these LocoNet devices, each providing up to 96 feedback inputs? What's the limit then? Greetings Bernhard
By bekoenig2003@... · #3914 ·
Re: Difficulty acquiring locomotives with a Duplex throttle
My understanding is that the UR's do need rail sync. Jeremy Janzen
By Jeremy Janzen · #3913 ·
Re: Difficulty acquiring locomotives with a Duplex throttle
Would it be sooo simple that the UR need th RailSync ?
By karst.drenth · #3912 ·
Re: YD6016LN and ESU LNet Converter
You could connect the YD6016LN on USB to it's Config Software. Then watch the logging screen and issue a Power-On - Power-Off.? That should be shown in the Logging. Greets, Karst
By karst.drenth · #3911 ·
Re: YD6016LN and ESU LNet Converter
Thank you. I'll keep trying! Chris
By cm_james@... · #3910 ·
Re: Difficulty acquiring locomotives with a Duplex throttle
I have mine UR93 and ur92's plugged into loconet B and they work fine. Something to try. Jeremy Janzen
By Jeremy Janzen · #3909 ·
Re: Feedback Sensors
Yes it does, but is in disguise ? it's the ext88N IN connector. Just use an RJ45 patch cable to the first ES-Module That's not the reason. Since it directly deals with high track current and
By karst.drenth · #3908 ·
Re: Feedback Sensors
Hi, We got this question in our ticket system as well ? Here is what I answered:
By karst.drenth · #3907 ·
Re: Difficulty acquiring locomotives with a Duplex throttle
Unfortunately the part of the LocoNet docs do not include the specs for working with the UR92/92 ? So we could not implement that feature. Greets, Karst
By karst.drenth · #3906 ·
Re: YD6016LN and ESU LNet Converter
Hi, No messages or reports from other customer who have problems with it. For sure there are people out there using it successfully. Greets, Karst
By karst.drenth · #3905 ·
Re: DR50018 Preset 1
Thanks for your reply Dennis, I thought that would be the case I'll give it a go. Matt
By Matt Wolstenholme · #3904 ·
Re: Difficulty acquiring locomotives with a Duplex throttle
Can you confirm that when you use the wired DT602D to acquire and control a loco that it still works when you then unplug the LocoNET cable?
By Oldngrey · #3903 ·
Re: Difficulty acquiring locomotives with a Duplex throttle
I disconnected everything except the UR93 from the LocoNet T (leaving the two boosters on LocoNet B). I acquired a locomotive ONCE with the UT6D, ran it and then released it. After that I could no
By Scott Walton · #3902 ·
Re: Difficulty acquiring locomotives with a Duplex throttle
Have you tried having the UR93 be the ONLY LocoNET device plugged into the YD7001? My quick test the other night was the bare minimum - just the YD7001, UR93 and DT602DE I seem to recall having an
By Oldngrey · #3901 ·
Re: Difficulty acquiring locomotives with a Duplex throttle
I moved the UR93 and throttles over to a mini-layout with a DCS50 (the original Zephyr command station). I had no problem acquiring and running trains with the UT6D or the DT602D (I never even plugged
By Scott Walton · #3900 ·
YD6016LN and ESU LNet Converter
I have successfully used the Digikeijs DR4088LN-CS with the ESU LNet Converter for block feedback. I have tried to connect the YaMoRC YD6016LN to a LNET Converter without success. Does anyone have
By cm_james@... · #3899 ·
Re: Difficulty acquiring locomotives with a Duplex throttle
I previously had a Digitrax DCS240 and had no problems. Since I moved to the DR500 and not YD7001 acquiring a locomotive over the Duplex network doesn't seem to work. It acquires fine when plugged in,
By Scott Walton · #3898 ·
Re: Difficulty acquiring locomotives with a Duplex throttle
Yes it does work. For me it happened instantly with no config required. A few things to check: * The green light on the UR93 should flash every second. If you make a change in the DT602D throttle (eg
By Oldngrey · #3897 ·
Re: DR50018 Preset 1
The best and safest way is use a relay to isolate the devices. Connect the relay coil to the DK50018 output and the relay contacts to the input of the lighting module.. Use a 12-16 volt relay
By Dennis Cherry · #3896 ·