Re: Can the DR60710 power supply cause damage to controllers it provides power to ?
It is nothing to do with having an earth in the outlet, although you should use such if using earthed equipment. In Europe (where outlets are earthed) anything which is exposed and powered like track has to fed from a supply that doesn't carry the earth through the power supply. Double insulation or class II is the easiest way to make sure that is true. I don't know what the rules are in Canada, I think in the USA you are free to take more risk.
?
Mike Ruby |
Re: DR4024 Servo decoder installation file.
开云体育? Feel free to upload it ? ? Iain Morrison 07767 456746 ? ? From: [email protected] <[email protected]> On Behalf Of Matt Wolstenholme via groups.io
Sent: 16 December 2024 13:54 To: [email protected] Subject: DR4024 Servo decoder installation file. ? Hi? ? Please does anyone have a copy of the DR4024 servo decoder installation software and instruction manual they could upload? The file in the files section is empty. ? Thanks (with fingers crossed!) ? Matt? |
YD7001 | Resetting Command Station after Short
Hello, (I have not read the manual, my apologies in advance.
?
Today during an operations session, there were many shorts, a good amount caused by operator error, but other from normal things. All the shorts were quickly cleared, but I then had to manually reset the YD7001. My layout is not that big, so originally I was not planning to install circuit breakers. But, I would also like a solution that will try to reset track power after a few seconds, only completely shutting down if the short is not cleared quickly.
?
Is it possible to set the YD7001 to retry track power after like 5 seconds, try 3 times, then require a manual restart after 15 seconds? Or some other similar scenerio?
Or do I need to get circuit breakers installed if I want this feature?
?
Thanks
--
Heath @ Human[c]ity |
Re: Can the DR60710 power supply cause damage to controllers it provides power to ?
Karst,
??? our club is in Toronto Canada and we will be replacing all of our Digikeijs booster and command station power supplies. ? I assume that thee 3 prong version, GSM60A, is the better choice for us in North American because all of our AC outlets have a ground wire. ? ?
?
Is this correct??
?
Or are there technical reason we should go with the B version anyway.
?
Andris
|
Re: YD7432 Reverser - recommended length of the Sensor track
OK thanks Karst. My layout is also 00/H0 and the longest locomotive is about 28cm so with S1 and S2 planned at approx. 60cm each and the Track Out still having a length of over 4m I'm well within the specs. All other track sections are supplied using YD6016 / DR4088 current sensors. |
Re: Can the DR60710 power supply cause damage to controllers it provides power to ?
Andris
?
The only additional comments that I will make on this topic is that Karst, in one of the previous posts, corrected his suggestion that we use the GSM60A supplies and instead stated that we should use the GSM60B supplies.? I cannot recall the reason for the change, but it should be somewhere in this topic.
?
Jay Lennox - Toronto |
YD7001 questions - booster, consisting
First, can the YD001 act as a booster, or just as a command station?
Second, plugging in a Digitrax throttle or using Engine Driver, can consisting be done on the throttle?
Third - is there a way to set the output voltage?? For example, for HO you might want 15 volts, but for N you would prefer 12.
Thanks,
?-bruce
nytrr@... |
YD7432 Reverser - recommended length of the Sensor track
I've just started implementing two YD7432 reversers each using S1 and S2 sensors.
What is the recommended (or minumum) length for each of these isolated track sections for a correct operation? I know that the the "Track Out" must be as long as the longest train, but could find no mention about the length of the shorter sensor sections.
?
Track is not yet laid so I can still adjust the plan according to your answer. Thanks in advance.
? |
Re: Can the DR60710 power supply cause damage to controllers it provides power to ?
Our club is in Toronto Canada and we will be replacing all of our Digikeijs booster and command station power supplies. ? I assume that thee 3 prong version, GSM60A, is the better choice for us since North American AC outlets have a ground wire.???? Is this correct? |
Re: YD7001 and decoder pro
On Sat, Dec 7, 2024 at 07:07 PM, Oldngrey wrote:
Can we please have an explanation of the reasons behind this or if this even matters? :) IB-II has more capabilities which are comparable to the YD70xx. So JMRI can use that then.? Plain Digitrax does not have that much features. Greets, Karst |