Re: DR5033 with Lenz DCC
I have a DR5000 with 2 DR5033 running 2 regions and the DR5000 running DCC accessories such as my DCC concepts Digital IP point motors - which I believe are pretty much like a tortoise but with a DCC
By
Adam Eddy
·
#3963
·
|
Re: Issues with DR5033s with upgraded DR5000 w/YD9401 module
Jim,
According to the DR5033 manual
I thougt common ground wiring referred to using a common track across all boosters not common power supplies.
You can configure the DR5033 from the YD7001. Just
By
Oldngrey
·
#3962
·
Edited
|
Re: DR5033 with Lenz DCC
Karst,
Thank you once again for the response. ?I understand that you do not like the auto reverse feature of the DR5033 however the Digikejis documentation says that the DR5033 has that feature.
By
Mike L <mjlinden58@...>
·
#3961
·
|
Re: Issues with DR5033s with upgraded DR5000 w/YD9401 module
I have a converted DR5000 with 4 DR5033 connected to a single regulated
power supply and this has shown no problems before or after the
conversion. I have all the DR5033 fuse protected but then that
By
tmose2012
·
#3960
·
|
Re: Issues with DR5033s with upgraded DR5000 w/YD9401 module
Thanks to all who responded and I greatly appreciate the feedback and recommendations. To be honest I researched the Digikeijs DR5000 and DR5033s, I did not find any information stating that it was
By
Jim Tatum
·
#3959
·
Edited
|
Re: Issues with DR5033s with upgraded DR5000 w/YD9401 module
For YaMoRC devices with HBridge it is not !! Every HBridge needs it's own double Isolated Switch-Mode powersupply. !!!
Not complying leads to Common Ground wiring, which is NOT supported and might
By
karst.drenth
·
#3958
·
|
Re: Purging locos YD7001
I could be wrong, but¡
I thought that release would remove the locomotives from the slot they were occupying.
Whereas Dispatch would maintain the slot, allowing someone else to pickup the loco or
By
Heath @ Human[c]ity Junction
·
#3957
·
|
Re: Purging locos YD7001
Jay,
Thank you for the clarification.
I use similar devices to you with WiThrottle, Engine Driver, WLANMaus but also the Z21 App on iPhone or Android.
I have turned off the YD7001 Wifi and use a
By
Brian A
·
#3956
·
|
Re: Issues with DR5033s with upgraded DR5000 w/YD9401 module
After I updated to the YD7001 I accidently crossed the track A/B wires on the YD7001 to where they were no longer common with the DR5033's. Swapping the wires on the YD7001 cured the short circuit I
By
Mike's DeepRun RR
·
#3955
·
|
Re: Issues with DR5033s with upgraded DR5000 w/YD9401 module
Moving back on topic in a moment:
I am moving from a Digitrax system to the YaMoRC/Digikeijs world with a few DR5033's and a YD7001. I got them a few months ago when YaMoRC stock was briefly available
By
Oldngrey
·
#3954
·
|
Re: Purging locos YD7001
Brian
I am going to take a shot at clarifying what Karst was saying about Release .....
In the WiThrottle protocol there are two commands that are supported - Release and Dispatch.? What they do is
By
Jay Lennox
·
#3953
·
|
Re: Purging locos YD7001
Hi Brian,
Well I actually meant thet releasing (purging) a refresh-slot is the responsibility of the controlling party. Not some kind of "garbage-collection" in the controll *ed* device, just because
By
karst.drenth
·
#3952
·
|
Re: Programming #YD8116 with #DR5000 via CVs - "old way"
#DR5000
#YD8116
Hi,
Ah... you seem to be a bit impatient... Posting a ticket last night ;) Signing with your name is also considered polite around here.
Your question:
No you cannot. Our decoders do not have CV's
By
karst.drenth
·
#3951
·
|
Re: Issues with DR5033s with upgraded DR5000 w/YD9401 module
It think I know some one Vienna Austria that has a couple for sale.
Richard
By
Richard Trilling
·
#3950
·
|
Re: Issues with DR5033s with upgraded DR5000 w/YD9401 module
Jim,
I will be following along as I am building a layout that has a YD7001 and a DR5033.
Have you tried adjusting the speed at which the YD7001 triggers a short? It might just be reacting faster
By
Heath @ Human[c]ity Junction
·
#3949
·
|
Re: Purging locos YD7001
Karst,
Thanks for your response, I understand you may not implement the functionality.
The Roco Z21 has implemented automatic release/purging of locos that have been stopped and are no longer
By
Brian A
·
#3948
·
|
Re: Issues with DR5033s with upgraded DR5000 w/YD9401 module
Where can you get a YD9401 in the US? Iron Planet is out of stock. Are they the only dealer?
Thank,
-bruce
Bruce G Alcock | OK N-Rail | 405-381-4314<tel:405-381-4314> |
By
Bruce Alcock
·
#3947
·
|
Issues with DR5033s with upgraded DR5000 w/YD9401 module
I have upgraded my DR5000 with the YD9401 module and followed all instructions as posted in this group and the the instruction found on the YaMorCo website. I have 2 issues at present.
1. The YD7001
By
Jim Tatum
·
#3946
·
Edited
|
Re: DR5033 with Lenz DCC
Well Mike,
As a "first" the DR5033 is NOT a reverse loop controller :O? That it worked in the first Loop, is based on pure luck...
As a matter of fact, people using the DR5033 in this way, caused a
By
karst.drenth
·
#3944
·
|
Re: Purging locos YD7001
Hi Brian,
Well, all you ask or expect to be present in the YD7001 is not there, and will not be there...
Why ? Well, simple: Your WiFiTrax system is obviously not capable of handling a standard
By
karst.drenth
·
#3943
·
|