Purging locos YD7001
Is there a setting on the YD7001 to purge stationary locomotives. The Z21 enables purging where no new commands have been issued for a number of minutes, the setting has various minute intervals that can be applied. ? Also is there a way to reduce the number of times an update is sent to each loco or how often a refresh of the commands is sent. I notice that some systems send updates for all locos almost constantly, whereas other systems have a much slower refresh rate.
If I restart the YD7001 everything goes back to normal running. Cheers Brian |
Re: DR5033 with Lenz DCC
Mike L
Thanks Karst.? I figured that was going to be the answer, but I was hopeful.
To answer your question, it's not just a DR5033.? It is connected to the LVZ100 through the CDE connection and to the track through the track output connection.? When it was only one DR5033, it handled the reverse loop aspect perfectly.? With two DR5033s, 90% of the time it works fine.? Occasionally, it will trip the LVZ100 breaker. But not often.? That's what led me to believe by having both DR5033s identified as Module 1, I wasn't always getting the reverse feature on the "right" DR5033.? Does that answer your question? -- Mike L |
Re: DR5033 with Lenz DCC
On Sun, Nov 19, 2023 at 07:13 PM, Mike L wrote:
because everything I've read here and Lenz group does not provide any process (that I've found) to program the DR5033 with the Lenz Express Net. ? You can't.? Need a LocoNet system to configure it through LNCVs. but...
How did you do that ? with only a DR5033 ?? |
DR5033 with Lenz DCC
Mike L
Hi folks.? My first post.? I have a Lenz LVZ100/LH100 (v3.6) system running my HO scale layout.? It is configured to have three power districts.? The Lenz LVZ100 is supplying the power to the middle power district.? The other two districts (which are reverse loops by the way) are powered by Digikejis DR5033s.? The middle district and one reverse loop have been in place for a year now and have been working fine.? I recently completed the second reverse loop and added the second DR5033.? Wiring is per Section 4.8 of the DR5033 manual. Here is where the question comes in. Does the second DR5033 new a different module address than the first one?? I believe the answer is yes.? Then, I believe I am stuck because everything I've read here and Lenz group does not provide any process (that I've found) to program the DR5033 with the Lenz Express Net. ? any suggestions would be greatly appreciated.
-- Mike L |
DR5000 protocol dropdown disabled in LAN settings
#DR5000
Hi all,
I'm coming back to modelling after a long while and dusting off my DR5000 (v1.5.5 firmware & app). I have connected to it fine with the app (using a Windows 10 VM on Linux), and can e.g. drive locos on on the track with its built-in throttle, update LAN and wifi settings fine, etc, etc. But I can't change the LAN protocol so as to be able to connect to it using JMRI. As you can see from the screenshot below, the dropdown is disabled, and I can't figure out how to re-enable it. Any suggestions? Thanks! Mike |
Locked
Re: YD4901 Availability
Speaking in the name of YaMoRC we are sorry for customers who's dealers let them pay on pre-order. Not all of them have this policy. We urged our dealers not to do pre-payment on pre-order after this came to our knowledge. ? Greets, Karst on behalf of YaMoRC ? |
Locked
Re: YD4901 Availability
Thanks for the info Iain, having paid for something 3 months ago is not a happy situation, but I now know where I stand.
|
Locked
Re: YD4901 Availability
Alan There is currently no supply to be had anywhere and you will need to wait until more area available. Many Thanks Iain Morrison On Mon, 13 Nov 2023 at 13:04, <alanmayfield@...> wrote: I realise that this is not a technical issue, I have had a paid pre-order for a YD4901 since August and still no sign of delivery. |
Locked
YD4901 Availability
I realise that this is not a technical issue, I have had a paid pre-order for a YD4901 since August and still no sign of delivery.
I live in Ireland, Brexit has made it more difficult to source from the UK.? Is anyone aware of a retailer who:
Regards Alan Mayfield |
Re: DR5013 slow response
Hi,
I had a couple of private emails asking how this issue was resolved.? The 5013 was probably faulty so I replaced it with a LODI KSM as recommended above.? Works fine now.? I had to switch off the led on the LODI to make it work for my system.? See my later post in July on me asking for advice for the LODI KSM Regards, John |
Re: Downgrade Procedure
The club has 3 DR5000 already converted to YD7001's. The club needs 14 wireless throttles and the DR5000 was handling this job in the past. Is it as easy as change the Wireless module back too the DR5000 unit and upgrade to V1.5.5 or 1.6.3 again? |
Re: Difficulty acquiring locomotives with a Duplex throttle
I tried a UR93 on the LocoNet B network and it didn't wokr there. I also tried a UR92 there and got only red/green flashing lights.So I am clear, the LocoNet B network is the Booster network, correct?? So it DOES have railsync, right? I ask because I have the UR93 (only) but have observed this same problem with my DR5000 (not yet upgraded) - though it appears to be intermittent. |
Re: Unable to operate a flashing LED with DR4018
Thanks Mike and Ian for your inputs. I thought this.would be a quick and simple solution to make crossing lights work in conjunction with a Green signal. I am using iTrain to control the layout and the signal goes Red when the next block activates switching the crossing light off. However it seems this isn¡¯t going to work.