Keyboard Shortcuts
Likes
- YaMoRC-Digikeijs
- Messages
Search
Welcome to the YaMoRC/Digikeijs English Forum
?
This Table of contents provides information about the YaMoRC and Digikeijs products in US English and JMRI.
Click on the "Read More" to see all the information.
Legal notice:
All instructions are written to the best of our knowledge and belief of the respective authors.
Nevertheless, no liability for any errors or omission in the Documentation is intentional!
?
General:
The Main website of the manufacturers YaMoRC and Digikeijs can be reached via the following link:
- Link to the
- YaMoRC Support for Documents. TBD
- Link to the Digikeijs Firmware:?The latest firmware for each product will be in its respect file directory if we have the latest firmware.
- This is an archive that was made and will have documents in other languages. Check before you download.
?
US Dealers:
- for YaMoRC and Digikeijs Products.
Click on any RED Model number below, it will send you to the files page for that device.
English Only Manuals and Photos, etc can be found on this Forum and elsewhere:
Central Station:
- DR5000 The first Command Station with all conceivable connection sockets and LED status lights, USB, LAN & WLAN
- Detailed Tutorial - Rudy's Model Railway Videos on DR5000
Booster:
- DR5033 3 amp Booster works with many different Command Stations
Switch and Servo Modules:
- DK50018 16 Channel Bluetooth accessory and switching decoder
- DR4018 16 Channel Multi-Protocol Switching Decoder
- Manual: DR4018 Advanced V1.2
- Video Series for the DR4018 or DK50018 on Preset 1 in JMRI to invert the outputs for LED Signals.
-
- Guide for Testing the DR4018/DK50018 for proper Preset Configuration.?
- DR4024 4-output multi-protocol servo decoder with 4 additional switching outputs
?
Feedback Modules:
- ?DR4088CS & CS-GND 16-input feedback module (S88)
?
- ?DR4088LN-CS, LN-GND & LN-OPTO 16-input feedback module (LocoNet)
-
?
- ?DR4088RB-CS & RB-OPTO 16-input feedback module (R-Bus)
?
- ?DR5088RC 16-input feedback module with RailCom (LocoNet)
?
Reverse Loop Module
- ? DR5013
- Video :?
Turntable Module
- ??? DR5052
?
Other Equipment
- ??? DR4050 DigiLEDs RGB Model Train Light Control
?
- ??? DR5022 DigiControl for the control of 2 trains via a swivel
?
- ??? DR5039 LocoNet-B to CDE
?
- ??? DR5097 DigiNetHub 10x LocoNet Hub
?
- ??? DR5098 DigiNetHub 10x X-Bus Hub
?
- ??? DR5099 DigiNetHub 5x X-Bus Hub & 5x LocoNet Hub
Software
- JMRI
?
- RocRail
-
- ITrain
- Train Controller
- Perecli RRA (Railroad Automation)
- ?
- ?
- ?
- ?
- ?
-
- AnyRail:
Throttles:
- Document showing the Apps that work with JMRI and DR5000 with download links.
- Roco WLANmaus Throttle Setup For The Digikeijs DR5000
- Test of the Proto-Throttle with the Digikeijs DR5000
- RtDrive Lenz With The Digikeijs DR5000
- ESU Mobile Control II Throttle With The Digikeijs DR5000
- DigiTrainsPro (Android Phone) DR5000 Setup (Now a monthly fee of 5 Eros for this version)
- Z21 App for Apple or Android Phones.?
?
Other Features:
- ?
?
?
?
Re: Feedback Sensors
Hi, ? LocoNet Feedback-Address-Space is 4096 addresses large. That means in theory 42 of these units.... ( with 96 contacts each ) ? But please note: One should prevent getting the ES-Link buscables much longer than 1 meter ( 3ft ) in total from YD6016LN to the last YD6016ES connected. ? As soon as the distance gets more than 1 - 1.5 meter (3-5ft) use another LocoNet YD6016LN and do the same trick. Reason: LocoNet is meant for 300ft at least. ES-Link is not. We find 5ft is the limit. Others might find that conservative.? ? Grtzz, Karst |
Re: Difficulty acquiring locomotives with a Duplex throttle
My understanding is that the UR's do need rail sync. Jeremy Janzen On Thu, Nov 2, 2023 at 10:39?AM karst.drenth <karst.drenth@...> wrote:
|
Re: Difficulty acquiring locomotives with a Duplex throttle
I have mine UR93 and ur92's plugged into loconet B and they work fine.? Something to try. Jeremy Janzen On Thu, Nov 2, 2023 at 9:18?AM karst.drenth <karst.drenth@...> wrote:
|
Re: Feedback Sensors
On Mon, Oct 30, 2023 at 03:50 PM, Oldngrey wrote:
* the ES-in versions still get their power from a LocoNET module closest to the command module. (YD7001 doesn't have an ES link connector)Yes it does, but is in disguise ? it's the ext88N IN connector. Just use an RJ45 patch cable to the first ES-Module * the unreleased RC version gets its power from the track since presumably it draws more than LocoNET can supply.That's not the reason. Since it directly deals with high track current and -voltages, the LocoNet interface must be completely opto-isolated. So it's processor runs off the track connection, the LocoNet interface from the LocoNet-Bus. * the main advantage of the ES versions is that I can configure several 6016 modules together with only one module needing to have a USB connection. (Ignoring the stick and Configuration module). So if I am prepared to configure each 6016 module on a computer before wiring it into the layout, then there is no need to have the ES wiring. The program button makes it even easier with no USB config required at all.I urge you to specify the full article number. Only talking about 6016 makes no sense. YD6016LN and YD6016ES?are completely different animals.?So what you wrote does not make too much sense ? * the GND version is used for switches - buttons or point motor feedback switches. But you could use a CS version in turnout mode. I haven't seen any examples of this online. To keep things less complex I could simply buy a CS instead of GND versions. There is a price difference but the CS is slightly more versatile should I need to re-design the layout. Yes, it's only the electrical interface that is different. ? Just made this sketch for a customer with an Z21 ? ? Greets, Karst ? |
Re: Feedback Sensors
Hi, ? We got this question in our ticket system as well ? ? Here is what I answered:?
Karst
? |
Re: Difficulty acquiring locomotives with a Duplex throttle
I disconnected everything except the UR93 from the LocoNet T (leaving the two boosters on LocoNet B). I acquired a locomotive ONCE with the UT6D, ran it and then released it. After that I could no longer acquire anything. I powered off both the YD7001 and the UR93 and tried again. It seems to ALMOST acquire a locomotive but can't complete the last step to notify the throttle. When I attempted to acquire a new locomotive which was sitting there on the track, with the sound idling, as soon I got almost to the end of the sequence (pressed the Loco button on the throttle the second time), the sound went off. This was a locomotive with an ESU Version 5 decoder which has the sound off until you turn on F8, so it seems that it sent out a packet with the new settings with F8 off.
I tried a UT4D but couldn't get anywhere with it, even when I plugged it in! Nearly everything else is working fine (I have signals working, detection working, Railcom readers working fine, but Digitrax throttles just aren't working. Scott Walton |
Re: Difficulty acquiring locomotives with a Duplex throttle
Have you tried having the UR93 be the ONLY LocoNET device plugged into the YD7001?
My quick test the other night was the bare minimum - just the YD7001, UR93 and DT602DE I seem to recall having an intial problem last year when the UR93 wasn't the first LocoNET device in the chain on my DCS240.? |
Re: Difficulty acquiring locomotives with a Duplex throttle
I moved the UR93 and throttles over to a mini-layout with a DCS50 (the original Zephyr command station). I had no problem acquiring and running trains with the UT6D or the DT602D (I never even plugged them in). I also tried both a DT402D and a DT502D throttle on the YD7001 with the UR93.? Both come up, recognized the the correct network and both immediately went to "Idle" When I plugged them in, I could acquire the locomotives but could not run them when the throttles were unplugged (bot flashed the light when any communication was attempted). Curiously, the Loconet monitor for JMRI was showing the throttle commands, even though the throttle thought they weren't going out.
So it appears that there is something going on in the Loconet that is causing the issue, but I don't have clue what it is. Does anyone have any thoughts? |
YD6016LN and ESU LNet Converter
I have successfully used the Digikeijs DR4088LN-CS with the ESU LNet Converter for block feedback.
I have tried to connect the YaMoRC YD6016LN to a LNET Converter without success.? Does anyone have experience of this configuration? Is it known not to work? Thank you Chris James |
Re: Difficulty acquiring locomotives with a Duplex throttle
I previously had a Digitrax DCS240 and had no problems. Since I moved to the DR500 and not YD7001 acquiring a locomotive over the Duplex network doesn't seem to work. It acquires fine when plugged in, but not when disconnected. I get the same results with both a DT602D and a UT6D. I will try with a DT500D and see if I get the same results. I have monitored the Loconet transmissions and it seems to be almost comnplete, just missing the last transmission back to the throttle. Heres the JMRI Loconet monitor for the relevant area:
09:36:17.643: [BF 0F 54 1B]? Request slot for loco address 2004.
09:36:17.646: [81 7E]? Master is busy.
09:36:17.661: [E7 0E 02 23 54 00 00 07 08 0F 00 00 00 63]? Report of slot 2 information:
Loco 2004 is Not Consisted, Idle, operating in 128 SS mode, and is moving Forward at speed 0,
F0=Off, F1=Off, F2=Off, F3=Off, F4=Off, F5=Off, F6=Off, F7=Off, F8=Off
Master supports LocoNet 1.1; Track Status: On/Running; Programming Track Status: Available; STAT2=0x08, ThrottleID=0x00 0x00 (0).
09:36:17.663: [81 7E]? Master is busy.
09:36:18.823: [B2 00 50 1D]? Sensor LS1 is High
09:36:19.674: [B2 00 40 0D]? Sensor LS1 is Low
09:36:21.995: [BA 02 02 45]? Set status of slot 2 to IN_USE.
09:36:21.997: [81 7E]? Master is busy.
09:36:22.001: [81 7E]? Master is busy.
09:36:22.005: [81 7E]? Master is busy.
09:36:22.030: [E7 0E 02 33 54 00 00 07 08 0F 00 00 00 73]? Report of slot 2 information:
Loco 2004 is Not Consisted, In-Use, operating in 128 SS mode, and is moving Forward at speed 0,
F0=Off, F1=Off, F2=Off, F3=Off, F4=Off, F5=Off, F6=Off, F7=Off, F8=Off
Master supports LocoNet 1.1; Track Status: On/Running; Programming Track Status: Available; STAT2=0x08, ThrottleID=0x00 0x00 (0).
09:36:22.032: [81 7E]? Master is busy.
09:36:23.819: [B2 00 50 1D]? Sensor LS1 is High
09:36:24.672: [B2 00 40 0D]? Sensor LS1 is Low
09:36:27.213: [BA 02 02 45]? Set status of slot 2 to IN_USE.
09:36:27.217: [81 7E]? Master is busy.
09:36:27.220: [81 7E]? Master is busy.
09:36:27.222: [81 7E]? Master is busy.
09:36:27.238: [E7 0E 02 33 54 00 00 07 08 0F 00 00 00 73]? Report of slot 2 information:
Loco 2004 is Not Consisted, In-Use, operating in 128 SS mode, and is moving Forward at speed 0,
F0=Off, F1=Off, F2=Off, F3=Off, F4=Off, F5=Off, F6=Off, F7=Off, F8=Off
Master supports LocoNet 1.1; Track Status: On/Running; Programming Track Status: Available; STAT2=0x08, ThrottleID=0x00 0x00 (0).
09:36:27.240: [81 7E]? Master is busy.
09:36:31.206: [BB 02 00 46]? Request data/status for slot 2.
09:36:31.223: [E7 0E 02 33 54 00 00 07 08 0F 00 00 00 73]? Report of slot 2 information:
Loco 2004 is Not Consisted, In-Use, operating in 128 SS mode, and is moving Forward at speed 0,
F0=Off, F1=Off, F2=Off, F3=Off, F4=Off, F5=Off, F6=Off, F7=Off, F8=Off
Master supports LocoNet 1.1; Track Status: On/Running; Programming Track Status: Available; STAT2=0x08, ThrottleID=0x00 0x00 (0).
09:36:31.519: [BB 03 00 47]? Request data/status for slot 3.
09:36:31.534: [E7 0E 03 03 00 00 00 07 08 00 00 00 00 19]? Report of slot 3 information:
Loco 0 (short) is Not Consisted, Free, operating in 128 SS mode, and is moving Forward at speed 0,
F0=Off, F1=Off, F2=Off, F3=Off, F4=Off, F5=Off, F6=Off, F7=Off, F8=Off
Master supports LocoNet 1.1; Track Status: On/Running; Programming Track Status: Available; STAT2=0x08, ThrottleID=0x00 0x00 (0).
09:36:31.834: [DF 00 00 00 00 20]? Query Tetherless Receivers.
09:36:31.844: [D7 22 00 08 20 22]? Unable to parse LocoNet message. contents: D7 22 00 08 20 22
09:36:31.861: [E5 14 03 08 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 05]? Query Duplex Group Name.
09:36:31.879: [E5 14 03 10 00 50 52 52 20 00 20 20 20 20 00 00 00 13 00 7E]? Reported Duplex Group Name="PRR? ? ?", Password=00000000, Channel=19, ID=0.
09:36:33.304: [B2 00 50 1D]? Sensor LS1 is High
09:36:34.157: [B2 00 40 0D]? Sensor LS1 is Low
09:36:35.109: [BF 0F 54 1B]? Request slot for loco address 2004.
09:36:35.124: [E7 0E 02 33 54 00 00 07 08 0F 00 00 00 73]? Report of slot 2 information:
Loco 2004 is Not Consisted, In-Use, operating in 128 SS mode, and is moving Forward at speed 0,
F0=Off, F1=Off, F2=Off, F3=Off, F4=Off, F5=Off, F6=Off, F7=Off, F8=Off
Master supports LocoNet 1.1; Track Status: On/Running; Programming Track Status: Available; STAT2=0x08, ThrottleID=0x00 0x00 (0).
09:36:35.127: [81 7E]? Master is busy.
09:36:38.999: [BA 02 02 45]? Set status of slot 2 to IN_USE.
09:36:39.002: [81 7E]? Master is busy.
09:36:39.006: [81 7E]? Master is busy.
09:36:39.008: [81 7E]? Master is busy.
09:36:39.032: [E7 0E 02 33 54 00 00 07 08 0F 00 00 00 73]? Report of slot 2 information:
Loco 2004 is Not Consisted, In-Use, operating in 128 SS mode, and is moving Forward at speed 0,
F0=Off, F1=Off, F2=Off, F3=Off, F4=Off, F5=Off, F6=Off, F7=Off, F8=Off
Master supports LocoNet 1.1; Track Status: On/Running; Programming Track Status: Available; STAT2=0x08, ThrottleID=0x00 0x00 (0).
09:36:39.034: [EF 0E 02 33 54 00 00 07 08 0F 00 24 6C 33]? Write slot 2 information:
Loco 2004 is Not Consisted, In-Use, operating in 128 SS mode, and is moving Forward at speed 0,
F0=Off, F1=Off, F2=Off, F3=Off, F4=Off, F5=Off, F6=Off, F7=Off, F8=Off
Master supports LocoNet 1.1; Track Status: On/Running; Programming Track Status: Available; STAT2=0x08, ThrottleID=0x6C 0x24 (13860).
09:36:39.037: [81 7E]? Master is busy.
09:36:39.037: [B4 6F 7F 5B]? LONG_ACK: Function not implemented, no reply will follow.
09:36:39.040: [A0 02 00 5D]? Set speed of loco in slot 2 to 0.
09:36:39.042: [81 7E]? Master is busy.
09:36:39.044: [81 7E]? Master is busy.
The message about "Query Tetherless Receivers" should be the time when I plugged the throttle in and then acquired the locomotive (address 2004). I have a YD70001 (upgraded from a DR5000) and two DR5033 boosters, 2 DR5013 reversers, 2 DR5088RC railcom readers, and many RR-CirKits devices (2 TC-64's, 1 TC-64 Mk II, many SignalMan, TowerMan, WatchMan and MotorMan devices).? Scott Walton |
Re: Difficulty acquiring locomotives with a Duplex throttle
Yes it does work. For me it happened instantly with no config required.
A few things to check:
|
Re: DR50018 Preset 1
开云体育The best and safest way is use a relay to isolate the devices. ? Connect the relay coil to the DK50018 output and the relay contacts to the input of the lighting module.. ? Use a 12-16 volt relay coil. ? ? Dennis Cherry ? Using my Desktop Computer, not my PCD. ? -- Dennis Cherry Owner/Moderator |