Re: YD7001 LAN Control
USB if the cable length is <= 2 meters
By
karst.drenth
·
#4410
·
|
Re: VOLTAGE FOR MARKLIN Z
Attached is an image of the invention of antiparallel diodes to lower the voltage. It would be 15v to 11.5v
In the Scale Z forum in Spain it indicates that this is a good voltage for digital.
Each
By
Mario <mario.chica.perez@...>
·
#4409
·
Edited
|
Re: YD7001 LAN Control
Thank you very much again for your help.
Just one more question if you allow me on this topic, what do you advise me to control the model, through USB or LAN cable?
Mario
By
Mario <mario.chica.perez@...>
·
#4408
·
|
Re: CONNECTION DR4088RB AND MULTIMAUS AT THE SAME TIME
Thank you so much for your help. What a joy.
By
Mario <mario.chica.perez@...>
·
#4407
·
|
Re: VOLTAGE FOR MARKLIN Z
The YD6016 does not have a thing to do with this. It will detect current, not voltage.
However... using the YD6016xx-CS will drop the voltage for about 1.1V.? The current sensor is built with two
By
karst.drenth
·
#4406
·
|
Re: CONNECTION DR4088RB AND MULTIMAUS AT THE SAME TIME
Don't need that, just plug the DR4088RB into the YD7001 and the MultiMAUS into the DR4088RB.
We are a bit more advanced than Roco with the Z21. We doe R-BUS and X-BUS on the same cable ;)
By
karst.drenth
·
#4405
·
|
Re: YD7001 LAN Control
Direct Cable connection between YD7001 and PC (
By
karst.drenth
·
#4404
·
|
Re: YD8008 and a relay
No Problem, just use a mono-stable spst relay. You might set the Pulse-Length in the YD8008 accordingly ( default = 30ms )
Greets,
Karst
By
karst.drenth
·
#4403
·
|
New Forum Name
The forum email has been changed to [email protected]
Welcome page will be corrected later today.
--
Dennis Cherry
Owner/Moderator
By
Dennis Cherry
·
#4402
·
|
YD8008 and a relay
Hi,
Is it feasible to drive 12v relays from a YD8008 that has YD6940s? I need the relay to only operate for about 300mS or a little longer in order to be the momentary trigger to an input of a timer
By
Oldngrey
·
#4401
·
|
Re: Change on the forum next week
Ok, De acuerdo. Me parece perfecto.
Okay, Okay. ?That seems perfect to me.
By
Pedro447
·
#4400
·
Edited
|
Re: YD7001 LAN Control
You need to give the PC and the YD7001 fixed IP addresses on the same
network, e.g. 193.168.0.1 for the YD7001 and 192.168.0.2 for the PC. They
will both need the same subnet mask 255.255.255.0.
Then
By
Iain Morrison
·
#4399
·
|
Re: CONNECTION DR4088RB AND MULTIMAUS AT THE SAME TIME
Would an adapter of this type be worth it?
By
Mario <mario.chica.perez@...>
·
#4398
·
|
Re: YD7001 LAN Control
Good afternoon.
The idea is to connect directly from the PC's network card to the YD7001-E without using any router. I have seen somewhere that no crossover cable is necessary but I don't know what I
By
Mario <mario.chica.perez@...>
·
#4397
·
Edited
|
Re: YD7001 LAN Control
I hope this helps. From what I can see the PC and the YD7001 are on different networks. The PC is 192.168.1.80 the number one being key here. Also the PC address is manually being assigned by the PC
By
Mike's DeepRun RR
·
#4396
·
|
Re: Change on the forum next week
Sounds good, thank you Dennis.
By
Vinny DeRobertis
·
#4395
·
|
Re: YD7001 LAN Control
Good morning.
This is where I have to modify the IP of my PC and put what the Yamorc YD7001-E indicates?
Sure, I have to see what my YD7001-E indicates
Thank you so much.
Greetings,
Mario
By
Mario <mario.chica.perez@...>
·
#4394
·
|
Re: Change on the forum next week
Deems logical.
By
R.
·
#4393
·
|
Re: Change on the forum next week
Dennis:
The new name is good.
Thanks,
Don Charabin
[email protected]> wrote:
By
Don Charabin
·
#4392
·
|
Change on the forum next week
I will be changing the Groups.io email from [email protected] to [email protected].
If you have any other suggestion for the new email name please let me know in the next 2 days.
This was
By
Dennis Cherry
·
#4391
·
|