Re: Servo Controller Alternatives
Hello, It is in fact both, I¡¯m running mine off a DR5000 as well via the DCC input and you just assign it an address as you do with a digikeijs switch unit. The other way you can use it is via
By
Nathan Miles
·
#3556
·
|
Re: Servo Controller Alternatives
I am also looking into the system2 items as I am planning to use MQTT (instead of LCC) on my next layout. Have you been able to reach anyone at Megapoints? I don¡¯t think they have a U.S.
By
Heath @ Human[c]ity Junction
·
#3555
·
|
Re: Servo Controller Alternatives
Thanks for your reply, I do t know Prima but guess it¡¯s a complete control system. I should have said I am using DR5000 with Itrain for control. I am just looking for additional point/frog control
By
Dave
·
#3554
·
|
Re: Servo Controller Alternatives
Morning, I use the prima which works a treat. To switch polarity I just have a frog gauge master auto frogs under each one but prima is a very good value for money controller and simple to program as
By
Nathan Miles
·
#3553
·
Edited
|
Servo Controller Alternatives
I am looking for some additional servo controllers with frog polarity control. I have been using DR4024 units with DR4102s on the frogs. I am considering megapoints system 2 as an alternative but just
By
Dave
·
#3552
·
|
Re: YD9401 Upgrade Tip
Hello Sir Here is a link to some very help full instructions about this install. https://www.dcctrainautomation.co.uk/user/Upgrade%20instruction%20YD9401.nl-en.pdf
By
James
·
#3551
·
Edited
|
Re: YD9401 Upgrade Tip
Yes, we are ;) Our slogan: FROM modellers FOR modellers ;)? I am as crazy about trains as you guys are :P Anyway, a verrrrry good tip !? As of the time difference you guys start playing when we get
By
karst.drenth
·
#3550
·
|
Re: YD9401 Upgrade Tip
And I just received the activation key, so they are working late on a Friday!
By
Bob Gamble
·
#3549
·
|
YD9401 Upgrade Tip
I just got my YD9401. It is a small board in a bag with a loose label. I went to the YaMoRC website for instructions which are in the form of a YouTube video. There is also some software to download
By
Bob Gamble
·
#3548
·
|
Re: DR5033 - should a short be detected between two power districts, each with its own DR5033 ?
Hi, A couple of words from the designer ;) First: The DR5033 was never intended to be used as an autoreverser. The so called "Phase detector" was a featured desired by late Mr. Keij Sr. ( because his
By
karst.drenth
·
#3547
·
|
Re: YD7001 LAN Connection
Dank Je Wel, Karst I have had to go away for 10 days, will try again when I get home Reg
By
Reg foster
·
#3546
·
|
Re: YD7001 LAN Connection
A direct cable link is also possible. You just have to set both YD9401 LAN and PC to have a fixed IP address ( static ) Just an example. How the PC has to be configured. depends on the windows
By
karst.drenth
·
#3545
·
Edited
|
Re: YD7001 LAN Connection
Ahh OK thank you Jay, I have an old one home somewhere. Probably behind the wallpaper. I shall dig it out and give it a go. cheers Reg Adelaide Australia
By
Reg Foster <regfoster@...>
·
#3544
·
|
Re: YD7001 LAN Connection
Reg I believe that to connect the YD7001 and a computer through a LAN connection you are going to need a router.? When a device connects to a LAN network it needs an ip address.? One of the
By
Jay Lennox
·
#3543
·
|
Re: DR5033 - should a short be detected between two power districts, each with its own DR5033 ?
Andrew Yes, the Tam Valley Auto Reverser could automatically correct the short by reversing the phases.? But I would still have a switch set against me if the loco keeps going, and I would end up
By
Jay Lennox
·
#3542
·
|
YD7001 LAN Connection
Hi All, real Ludite question. Just upgraded the DR 5000 to YD7001. Went smooth as silk. I own Traincontroller 9 silver but thinking about upgrading to Gold 10. I currently use the TC Gold Demo program
By
Reg foster
·
#3541
·
|
Re: DR5033 - should a short be detected between two power districts, each with its own DR5033 ?
Hi With My layout, I have used a Tam Valley Auto Reverser , this section of track is made at a train length long .ps this section is a straight through section . I have no problems. Tam Valley Depot,
By
@scoot
·
#3540
·
Edited
|
Re: DR5033 - should a short be detected between two power districts, each with its own DR5033 ?
Hi First I will answer Adam's question.? Zorra is simply a spot on the layout where there is a switch that allows the single track mainline to be split into two tracks to allow trains to pass.? It
By
Jay Lennox
·
#3539
·
|
Re: DR4088LN-OPTO - rapid flashing of red light
My WiFi module is being delivered today. -- Dennis Cherry Owner/Moderator
By
Dennis Cherry
·
#3538
·
|
Re: DR4088LN-OPTO - rapid flashing of red light
Very encouraging.? Thanks Karst and Vinny.? A rapidly flashing red light made me wonder if the board was slowly melting before my eyes.? I figure the board can blink all it wants if that means it
By
ClearToSlow
·