Re: DR5000, DR5033 and DR4088 on LocoNet
Yes, keep them separate. ?I believe loconet T has 12V supply whereas loconet B doesn¡¯t
By Adam Eddy · #3722 ·
Will adding an LED to a track (to indicate it is on) trigger the detection of the 4088CS?
I know that I should just put together a test setup and confirm all of my assumptions, but I figured I would get other people's experieces first. I want to know if I put an LED on a track bumper that
By Heath @ Human[c]ity Junction · #3721 ·
DR5000, DR5033 and DR4088 on LocoNet
Hello, I think I know the answer, but I want to confirm while I am planning out my layout. With Digitrax, there is only one LocoNet bus, and you connect the boosters and throttles, etc... all to the
By Heath @ Human[c]ity Junction · #3720 ·
Roco Throttles failing to connect to Yamorc 7001
I upgraded my Digikeijs 5000 to the Yamorc 7001.? I connected all my Rocos to the upgraded command station.? Have been running trains with the different throttles all week.? Today I had 7 operators
By [email protected] · #3719 ·
Re: YaMoRC YD8116 and Digikeijs DR5000
Thanks Iain.
By jw.ramsay@... · #3718 ·
Re: YaMoRC YD8116 and Digikeijs DR5000
Yes, no problem ¨C DCC equipment will work with a DR5000. Sent: Thursday, September 14, 2023 8:58 AM To: [email protected] Subject: YaMoRC, Digikeijs, JMRI, English YaMoRC YD8116 and Digikeijs
By Iain Morrison · #3717 ·
YaMoRC YD8116 and Digikeijs DR5000
I am considering buying some MTB MP5 point motors and using the YD8116 to switch them and before I do just want to know whether the YD8116 will work with an unconverted DR5000. Sorry if this is a daft
By jw.ramsay@... · #3716 ·
Function key 2 (F2) is latching / non-momentary on the YD7001 ?
Hi ****? This is a repost of a topic I opened on the YaMoRC forum by mistake.? Sorry for the duplication for some of you. **** On the YD7001 we have discovered that in our environment F2 is
By Jay Lennox · #3715 ·
Re: 3 more dr4088lncs for sale
?50 each incl p&p
By Alan Watt · #3713 ·
Re: 3 more dr4088lncs for sale
Alan, how much do you want for these modules please? -- Dave, Portland
By Dave · #3712 ·
Re: DR5000 Program Track Loco long address
Hi Dennis EU59826 LokPilot 5 Micro - 6-pin w/wires. Have two do the same. Andrew.
By @scoot · #3711 ·
Re: DR5000 Program Track Loco long address
You did not mention what decoders? If that have sound, try muting the sound first. On Tue, Sep 12, 2023 at 8:54 PM, andrew_pink58@...<andrew_pink58@...> wrote: Hi I am having
By Dennis Cherry · #3710 ·
DR5000 Program Track Loco long address
Hi I am having some issues with programming locomotive with long address. First if I use JMRI Decoder Pro I get a message can not communicate with the command station ,ps I changed the USB Cable.no
By @scoot · #3709 ·
Re: DR5000 Upgrade to YD7001 at York Railway Modellers in Toronto
Jay, Thanks for all the testing/information/tips you are providing. It has helped with my setup. I have a large garden railway, O Gauge, that I use the YD7001 as the controller. I run the Z21
By Brian A · #3708 ·
Re: DR5000 Upgrade to YD7001 at York Railway Modellers in Toronto
It has been a while since I reported on our progress.? We have had a number of items we had to overcome to connect more throttles. We did manage to get our two WLANmaus throttles to connect to the
By Jay Lennox · #3707 ·
Re: De sensitise DR4088LN-CS inputs.
Ryan: I have read about adding resistors to the DR4088 to desensitize the device but never understood how this was to be accomplished until I saw your photos. Awesome, thanks!!! Just to help me
3 more dr4088lncs for sale
i have 3 more dr4088lncs for sale Please email if interested Thanks Alan
By Alan Watt · #3705 ·
Re: Difference between DR5000 and YD9401
Weird, sorry to say. In a way there seems to be an Hate/Love relation between RocRail and LocoNet. One of my alpha-testers runs RocRail.? Guess with what... LocoNet Binary on LAN
By karst.drenth · #3704 ·
Re: De sensitise DR4088LN-CS inputs.
Welcome :) The comparison by itself is ok, no problem. But we had a lot of not so nice emails, phone calls and even "visits" of people thinking/assuming YaMoRC is "Just Another VERSION of Digikeijs"
By karst.drenth · #3703 ·
Re: Difference between DR5000 and YD9401
Issue has been resolved and it appears to be part of the Loconet buffering in RocRail.? I changed things ove to LbServer and it all works again as before. Thanks for all the help. Thomas
By tmose2012 · #3702 ·