Re: Connecting WLANMaus throttle to YD7001


 

The standard networking port for the Z21 protocol is 21105, you also need to put the address of the YD7001 into the multimaus as the Z21 interface

Many Thanks

Iain Morrison



On Mon, 28 Aug 2023 at 17:41, Jay Lennox <jay.lennox@...> wrote:
Hi

Now that there is support for multiple throttle connection protocols through the YD7001, I am trying to understand what we need to input into the WLANMaus to get it connected to the port on the YD7001 that is listening for the Z21 protocol.? On the DR5000 there was only one port and it only supported one protocol at a time, so there was no need to input a port number into the WLANMaus settings.

I have the YD7001 connected via the LAN port to a router.? Connecting wirelessly to the router is easy - enter SSDI and password into the WLANMaus?settings.? Next logical step would be to input the IP address of the YD7001 into the WLANMaus settings - I believe I have done this correctly using the information from the YD7001 app on a connected windows computer.? However, I do not know where in the WLANMaus settings to enter the port number that is listening for the Z21 protocol message stream - I can see what is is from the YD7001 windows app, but I do not know where to enter this information into the WLANMaus??settings.

If the port number does not need to be entered, that would suggest that the the WLANMaus is assuming a standard port number.? Does anyone know what that port number is so I can check that it is set correctly in the YD7001 by looking at the app screens?

Thanks for you assistance.

Jay Lennox - Toronto