Re: RM585A won't slide out of case
I have encountered this with other scopes, both a 2465 and a 475, both of which had dents in the corner of the outer metal case. When the rear plate reached the dent the case stopped sliding, hard!
By Jeff Dutky · #191114 ·
Re: Hakko 470 Problems
Try cleaning the vaporized flux residue from the valves on the pump. Cleaning the flux from the carbon vanes in my Pace desoldering station has fixed a low vacuum problem. Glenn
By Glenn Little · #191113 ·
Hakko 470 Problems
I've decided to resurrect my used Hakko 470 so I can do some better desoldering on my Tek and other boards. After cleaning the hole through the heating element and ensuring the rest of the
By n4buq · #191112 ·
Re: Type 130 L-C Meter
Ah, so. Thanks.
By Jerome D Leach · #191111 ·
Re: Type 130 L-C Meter
If the cap rebounds between one multivibrator pulse and the next, the meter will read high at the low end (low frequency, large rebound) and low at the high end (high frequency, small
By Dave Wise · #191110 ·
RM585A won't slide out of case
I have a RM 585A in reasonably good shap, but it won't slide more than about 1" out of the case before something on the right (CRT) side hit and prevents the scope from coming out - has anyone else
By Mark Henze · #191109 ·
Re: Type 130 L-C Meter
"Check them for Dielectric Absorption." Okay. So I read a bit on DAR, which I had not heard of (that I recall). Read about Dissipation, Q, and such, but not Dielectric Absorption. I understand it as
By Jerome D Leach · #191108 ·
Re: Type 130 L-C Meter
Rather coincidentally Mr Carlson, of the eponymous Lab, just posted a video on a very clean Type 130 that he owns. https://www.youtube.com/watch?v=gWSBcsWpjjE
By toby@... · #191107 ·
Re: Type 130 L-C Meter
Check them for Dielectric Absorption. Dave Wise Sent: Sunday, February 20, 2022 11:56 AM To: [email protected] Subject: Re: [TekScopes] Type 130 L-C Meter <snip> I will re-install [the original
By Dave Wise · #191106 ·
Re: Type 130 L-C Meter
Great comments all! I am enjoying this immensely, and some of this information is actually ever so imperceptibly leaking into my wrinkled, ancient, ossified brain. The saga of the 130 continues.
By Jerome D Leach · #191105 ·
Re: P6015A HV probe, trimpot R7 value?
Jared, Ijust have re-read your post, it seems like you want to convert 6015 to 6015A, can you please clarify your intentions? These are different "animals" I believe that cables, comp box and tip
By Jean-Paul · #191104 ·
Re: P6015A HV probe, trimpot R7 value?
Jared, on my one of my 6015A R7 is 500 Ohm, Bourns 3362 cermet. clear schematics should be easily available. PM me if you want a scan off my paper manual. jon
By Jean-Paul · #191103 ·
P6015A HV probe, trimpot R7 value?
Hi, I just picked up a P6015 HV probe and am designing a replacement P6015A compensation box as the BNC on mine is broken and I want to add Tekprobe functionality (plus allow easier adjustment with
By Jared Cabot · #191102 ·
Re: Tek 2715 75 to 50 ohms conversion
After observing the comments and suggestions, I have to jump in here. Basically, you want your 2715 analyzer to be a 2712? Why? It is already better than a 2712. I realize the input connector is an
By WB6GHK · #191101 ·
Re: 2465 Delta Cursor not visible
What's the voltage on the DLY_REF_1 line itself? Does it recover if you disconnect P511? I seem to remember cases where the bypass caps on the A1 board have gone leaky and caused issues like this.
By Sigur?ur ?sgeirsson · #191100 ·
Re: Tek 2715 75 to 50 ohms conversion
Hi Jaap, I did reply by email. But it seems you did not get my replies. By changing to the 2712 software you mean changing the motherboard resistors so the analyser things its a 2712?
By arainhoneves · #191099 ·
Re: Tek 2715 75 to 50 ohms conversion
Thanks for the help. So from the replies it would better to use a min loss pad or change the complete connector.
By arainhoneves · #191098 ·
Re: 2465 Delta Cursor not visible
Many thanks Siggi for the feedback. I had actually just trawled through the manual and discovered this info (I'd missed it because I didn't understand where such functionality took place). I have now
By NigelP · #191096 ·
Re: Interface cards for Tektronix DAS 9100 Logic Analysis System
Hi Tom , I have a system and would be interested in spare cards/parts . Where are you located , I'm in the UK so post could be a real problem cost wise . regardsBrian (UK)
By Brian · #191095 ·
Re: Super Clean 570 Curve Tracer on Craigslist
When does collecting old Tektronix equipment , appreciating a NOS looking and well cared for early vintage curve tracer, and collecting (repairing, restoring, learning from) old Tek gear, ever need to