Re: 577 Retrace Problem
See the note on page 10 of the operations manual regarding conditioning of the storage CRT if it has been turned off for two weeks or more. Craig
By Craig Sawyers <c.sawyers@...> · #152748 ·
Re: Curve Tracer 577 - Power Supply Overhaul
On Fri, Nov 23, 2018 at 09:35 AM, Wolfgang Schraml wrote: > > On Tue, Nov 13, 2018 at 07:31 PM, Chuck Harris wrote: > > > > > I had a consulting contract years ago to help a > > Swedish company with a
By Wolfgang Schraml · #152747 ·
Re: 577 Retrace Problem
On Sat, Nov 24, 2018 at 03:56 AM, tom jobe wrote: > > What you are seeing on your 577 with these settings is as good as > anything I have ever seen on my 577. The different behavior with > different
By Wolfgang Schraml · #152746 ·
Re: Isolating methods, was RE: [TekScopes] Floating Adapter 013-0156-00
Or an A6902 isolation amplifier, which will take dual channel measurements from DC to 20MHz at up to +/- 3000V relative to ground. http://w140.com/tekwiki/wiki/A6902 Craig
By Craig Sawyers <c.sawyers@...> · #152745 ·
Isolating methods, was RE: [TekScopes] Floating Adapter 013-0156-00
Or you could use a Tek A6901 Ground Isolation Monitor. That measures the difference between input and output grounds, and if it exceeds +/-40V peak or the ground leakage exceeds 0.5, 3.5 or 5mA, it
By Craig Sawyers <c.sawyers@...> · #152744 ·
Re: tektronix 475 help replace diode
I just looked at the qservice site and available the original $ 3 I order it immediately thanks for the information and help Roberto
By Roberto · #152743 ·
Re: tektronix 475 help replace diode
Thanks I do not know the manual only shows two codes of the diode cd12676 or fd3375 I do not know if diode 1n4148 could be fine on and found ebay seems to me too high tax price for a diode original
By Roberto · #152742 ·
Re: Floating Adapter 013-0156-00
The isolation transformer adds the second isolation to make it double insulated. Either way there always need to be two means of protection against accidental contact, for example basic insulation and
By stefan_trethan <stefan_trethan@...> · #152741 ·
Re: 577 Retrace Problem
What you are seeing on your 577 with these settings is as good as anything I have ever seen on my 577. The different behavior with different amount of steps is very normal too. Depending on settings
By tom jobe <tomjobe@...> · #152740 ·
Re: tektronix 475 help replace diode
Roberto...does it have to be a special Tektronix diode?....if not replaceable by some commoner one Dinos in Greece may have them....(qservice-electronics in Rhodes) Dennis Tillman recently put Dinos'
By Jack · #152739 ·
Re: Floating Adapter 013-0156-00
Removing an earth does not make anything doubly insulated unless it already was doubly earthed . Earthing the case of an isolating transformer is not the same as connecting it to the chassis of the
By Jack · #152738 ·
tektronix 475 power supply repair succesful working !!!!!
hello to all my usual problem with tektronix 475 in the power supply voltages since now: 50v 33 v 50v to reg 67 105-160v 132 + 15v 5.53 5v 3.25 -15v -8..8 -8v -5.12 110 v 86.4 v Fixed the problem
By Roberto · #152737 ·
Re: Floating Adapter 013-0156-00
Chapter and verse about isolation transformer configurations here https://www.middleatlantic.com/resources/white-papers.aspx And here, towards the end https:/
By Craig Sawyers <c.sawyers@...> · #152736 ·
tektronix 475 help replace diode
hello all groups I have to replace it in my oscilloscope tek475 part TEKTRONIX 152-0246-00 DIODE SILICON 400piv 200 ma , cd12676 help me Roberto
By Roberto · #152735 ·
Re: Floating Adapter 013-0156-00
Thanks, Egge Siert. I found the manual and in fact useful schematic to use this floating connector. .
By BUR · #152734 ·
Re: 577 Retrace Problem
OK. I uploaded another series of pictures. Same folder: /g/TekScopes/album?id=79121 I used a different 2N3055 than in the previous pictures. Settings: - Vertical: 50mA/Div -
By Wolfgang Schraml · #152733 ·
Re: 577 Retrace Problem
On Fri, Nov 23, 2018 at 05:11 PM, Chuck Harris wrote: > > I have to wonder what were your settings for H Voltage, and > V Current, Supply voltage and load impedance, and your step size. > > You can
By Wolfgang Schraml · #152732 ·
Re: Floating Adapter 013-0156-00
Hi Craig. The question of isolation transformer never really goes away. If you continue earthing of say an isolating transformer case to a ¡®consumer¡¯ case when servicing consumer/appliances you
By Jack · #152731 ·
Re: 577 Retrace Problem
I have to wonder what were your settings for H Voltage, and V Current, Supply voltage and load impedance, and your step size. You can curve trace a 3055 at amps of current, or you can trace it at
By Chuck Harris <cfharris@...> · #152730 ·
Re: Floating Adapter 013-0156-00
That again. No it's not an absolute requirement that there is a ground connection to the output of an isolation transformer. In fact european standards absolutely demand that there not be one. The