Date
Re: Would like to have a TDS684A LPVS Capacitor list before disassembling the entire unit
By Ray · #171515 ·
Re: 2247A Counter/Timer Calibration question
Guess you're assuming that the battery was nominal and that there is some form of above normal battery current leakage? Any idea what should be the expected current parameters? Would this even be
By Alex · #171514 ·
Re: 2247A Counter/Timer Calibration question
You should measure the current. Regards
By Tom Miller · #171513 ·
Re: 2247A Counter/Timer Calibration question
Since its so easy to open up this scope today removed battery without even having to move the board, and it only measures 0.11V. I don't understand how a backup battery can get this low in only 8
By Alex · #171512 ·
Re: Tek 4041 GPIB Controller
Monty: Please let me know if you ever have a working ROM for the 4041. I would be willing to buy one for a reasonable price. This is the route Tektronix should have gone instead of forcing us to boot
By Gary Robert Bosworth · #171511 ·
Re: Need some R5030 help and a manual.... + temp problem SOLVED!
Thanks for the idea of removing the *front bezel* to get at the fiber-optic display on the R5030. Viewed from above, it seems to be bolted in from all sides in a totally inaccessible way, but maybe
By walter shawlee <walter2@...> · #171510 ·
Re: Tek 4041 GPIB Controller
Keep it up, Monty I, for one, am looking over your shoulder with interest! DaveB, NZ
By Dave Brown · #171509 ·
Would like to have a TDS684A LPVS Capacitor list before disassembling the entire unit
Dear All, I have this scope and I have been suggested in other topic of this forum to Recap at least the LPVS. Since I live in Brazil, I don`t think I can buy any Cap from the local supplier since 99%
By Rogerio O · #171508 ·
Re: Where is my 5030 coming from?
Hi Egge Siert, I saw Kurt was mentioned as the author of the pictures but there's still quite a gap - geographically as well... Raymond
By Raymond Domp Frank · #171507 ·
Re: Tek 4654M; No Trace, No +5V, No +95V; Help
By Bert Haskins · #171506 ·
Re: A Primer of Waveforms and their Oscilloscope Displays
The first 10 pages of 20 are here: https://www.pearl-hifi.com/06_Lit_Archive/15_Mfrs_Publications/35_Tektronix/A_Primer_of_Waveforms_and_Their_Oscilloscope_Displays-1-thru-10.pdf There were a couple
By Bill Perkins · #171505 ·
Re: Where is my 5030 coming from?
Hi Raymond, I assume Kurt, like me, also roams the internet looking for interesting items and their pictures. Greetings, Egge Siert
By Egge Siert · #171504 ·
Re: A Primer of Waveforms and their Oscilloscope Displays
I would certainly be interested in seeing a scanned copy of this waveform pamphlet. I learn something new every day. Gary -- Gary Robert Bosworth grbosworth@... Tel: 310-317-2247
By Gary Robert Bosworth · #171503 ·
Re: Tek 4654M; No Trace, No +5V, No +95V; Help
Harrison, With F558 blown (or removed), what kind of resistance from the junction of F558/L558 and ground do you see? Yes, it's a very basic question, but I'm wondering if something is being
By n4buq · #171502 ·
Re: SC502 Old Enough to Smoke?
I think I've found the problem. I disconnected the voltage multiplier (A1U850) from the HV traansformer (A1T800) and attached a NE-2 lamp to the transformer output through a 100Mohm resistor, and
By DaveH52 · #171501 ·
Where is my 5030 coming from?
Triggered by Walter Shawlee's recent topic about his R5030: A while ago I noticed that all but a few external photos in Tekwiki's 5030 article show my 5030, that very sample. Does anybody happen to
By Raymond Domp Frank · #171500 ·
Re: Need some R5030 help and a manual....
Have a look at the manual of the R5031 on TekWiki. The R5031 is the bistable storage rackmount version of the 5030. Its manual is available there. The readout is mounted the same as in the 576, like I
By Raymond Domp Frank · #171499 ·
Re: Need some R5030 help and a manual....
Doesn't it work the same as the 576, IOW remove the CRT bezel and pull out the readout module from its edge connector at the back? Raymond
By Raymond Domp Frank · #171498 ·
Re: 2247A Counter/Timer Calibration question
Hi Walter, Thank you for the information, and that exposed crystal certainly sounds like a reasonable explanation for the low spec frequency adjustment called for in the cal procedure with the case
By Alex · #171497 ·
Re: A Primer of Waveforms and their Oscilloscope Displays
My room was the single room on the second floor of my parents house, and I had the same problem with too much heat in the summer and too little in the winter. But I kept a R390 on at night and it
By Richard in Edenton NC · #171496 ·