Re: 2440: GPIB
On 03/15/2013 02:37 AM, Mark Wendt wrote: > On 03/14/2013 03:18 PM, John Miles wrote: >> >> >> Actually the software's free from http://www.ke5fx.com/gpib/7470.htm >> . I was using a 2430A when I
By
David Gravereaux
·
#88920
·
|
Re: New 466 owner
I've also been known to replace the fiberglass with a normal grocery-store style wooden skewer. Then ones I have are exactly the same size. Respectfully, Cliff White, W5CNW
By
Cliff White
·
#88919
·
|
Re: How to upgrade a 7854 to opt 2D
There are two versions of board A29 divided at 7854 serial number B085124 and below but the schematics are basically identical. DG181 is the part number used for a bunch of the analog multiplexors.
By
David Hess
·
#88918
·
|
2465A refurb
I'm thinking of buying the parts to refurb my 2465A, but I wanted to know if the parts documented in the 2465B restoration PDF have a good chance of being the same. The service manual I have does not
By
tonyp2422
·
#88917
·
|
Re: New 466 owner
Thank you for all the suggestions. I think I will try the tubing. With a bit of luck, might even be able to do it a part gripper and not need tearing down down the scope. Now to find a cover... -d
By
Dan Aldrich
·
#88916
·
|
Need help with P6133
I'm sure I'm being a dummy, but I suddenly am getting no signal continuity through the spring hook tip when placed on one of my P6133 probes. I'm just about certain I used this same spring clip on
By
tonyp2422
·
#88915
·
|
Re: New 466 owner
I often use silicon fuel tubings as used for miniature (1:8) petrol racing cars. Make sure the inner diameter is small enough to give a tight fit and use length of 1 - 1.5", so it won't slip. Wall
By
raymonddompfrank <r.domp.frank@...>
·
#88914
·
|
Re: How to upgrade a 7854 to opt 2D
Hi David, On "my" schematic 34 there is no U1620A or U2 and no D181 or U3. I found the TL 72 OpAmp. I have a U900 aa vertical D/A converter an a U1010 as horizontal D/A converter. Gerhard
By
g_kupka <ghm1@...>
·
#88913
·
|
Re: New 466 owner
Those fragile plastic flex connectors are impossible to find as far as I know, but I question whether a flex coupler is even needed there. The VAR shaft from the knob back to that flex connector is a
By
Tom Jobe <tomjobe@...>
·
#88912
·
|
Re: How to upgrade a 7854 to opt 2D
I assume that the character display works correctly even when the stored signal has no or a low vertical deflection. I think you will find the problem around U1620A or U2 on schematic 34. If reseating
By
David Hess
·
#88911
·
|
Re: How to upgrade a 7854 to opt 2D
After a warmup time of approx 2 hours the stored signal is displayed in the stored mode but only with an ampltude of 35% of the applied signal. Gerhard
By
g_kupka <ghm1@...>
·
#88910
·
|
2465 Failures & Serial Numbers
I find references to 2465s within a range of serial numbers having a "higher than normal" IC failure rate, but have been unable to find which serial numbers. Please point me in the right direction.
By
Frank Edwards
·
#88909
·
|
Re: How to upgrade a 7854 to opt 2D
I swapped the RAM Board and now the 2nd 7854 has the opt 2D. The 1st 7854 has still the problem, that it doesn't display the stored signal in the store mode, it shows only a horizontal line. Where can
By
g_kupka <ghm1@...>
·
#88908
·
|
Re: New 466 owner
I'm looking for same item Paul K0UYA
By
Paul Kraemer <elespe@...>
·
#88907
·
|
Re: Free: collapsible viewing hood and dust cover for 453/4, Tekcamera C12 adapter
Items gone, thanks for all your responses. Keith
By
keithostertag <keitho@...>
·
#88905
·
|
New 466 owner
Just picked up a 466 over the weekend. Works fine, but the only problem was the Var knob on CH 2 is broken. Opened it up and saw it was the coupler that connects the two shafts that's broken. Is there
By
Dan Aldrich
·
#88906
·
|
Re: 2432a lives again
It is the same basic oscilloscope as a 2430, 2430A, 2432, and 2440. They pretty much all only differ in bandwidth and sample rate. The 2431L is a little different being a cost reduced version that
By
David Hess
·
#88904
·
|
Re: Tek 455 horizontal sweep power supply problem
Do you have a copy of the service manual? It has detailed disassembly instructions in the maintenance section. A good copy is here http://w140.com/tekwiki/wiki/455 What does the +32 volt unregulated
By
Tom Miller
·
#88903
·
|
Tek 455 horizontal sweep power supply problem
Hi, My 455 that has performed perfectly for 18 years has developed a problem with the horizontal sweep. It appears to be a bit compressed on both sides and behaves like there is some oscillation on
By
wb6yte <wb6yte@...>
·
#88902
·
|
2432a lives again
I finally tracked down a shorted 2.7uf tant on the timebase board and got that replaced today. After putting everything together it booted up and passed all the self tests. I have it hooked up to my
By
Paul Amaranth
·
#88901
·
|