Folks, The Tektronix 108 manual is here: http://w140.com/tekwiki/wiki/108 Here is a list of manuals that are needed, but not available: http://w140.com/tekwiki/wiki/List_of_manuals_that_are_needed If
By
sipespresso <sipespresso@...>
·
#70102
·
|
Re: 475 no trace problem.
Found a problem area in the vertical output board. 18v and 48v on outputs to the plates and no signal on them. The signal exists on both inputs to u470 and is within spec. Disconnecting the plate
By
dannyzukov
·
#70101
·
|
Re: Power supply problem with Tek 2220
I saw your 2220 question the first time you posted it a few days ago, and I did not have a nice short answer for you. Since you have not gotten the answer you were looking for, let me comment a bit on
By
tom jobe <tomjobe@...>
·
#70100
·
|
Re: TR502 7L13/14 etc Lemo connector
Hello, I went to lemo.com and selected the nearest office contact details and sent them an email inquiry. I am shamed to admit that "right now on my desk" actually means they have been buried under
By
nukescope
·
#70099
·
|
Re: Nuvistors.
Hi to All, Tek used the 8393 Nuvistors in the Type 1A6 and 1A7. Look at the Circuit Description of both Plug-Ins and you know why. The so called differential adjustment of heater voltages. In addition
By
Egge Siert <eggeja@...>
·
#70098
·
|
Re: 7T11 Sequential/Random Problem
Probably meaning it's only there at the fast ranges, 500 ns and 50 ns? The Rate meter can cope with an enormous range of repetition rates, split in 3 parts IIRC (more or less logarithmic). Because of
By
Albert <aodiversen@...>
·
#70097
·
|
Re: SG503 - Troubleshooting
Hi Patrick, I have some good news: my SG503 is fixed and running. With your and David's help, I identified Q180 (2N3906) as having failed . C180 was also damaged (open). R180 and R216 had signs of
By
[email protected] <avassilicos@...>
·
#70096
·
|
Re: 7T11 Sequential/Random Problem
Is this the kind of application where the differences between saturating (TTL) and non-saturating (ECL) logic would apply? I wonder if the extra jitter is from poor power supply rejection.
By
David Hess
·
#70095
·
|
Re: 7T11 Sequential/Random Problem
I recall the behavior's independent of rep rate (at least between 1 kHz or so and 1 MHz). I initially saw it with my homebrew avalanchers, but it also was apparent with 067-0681-01 (driven at whatever
By
Mike
·
#70094
·
|
Re: Nuvistors.
r. Unfortunately Q203 is one of the more tedious-to-replace transistors in the HP130C, so at present it's put-off-today-what-you-can-do-later :), with the added excuse: experimentally lets see how
By
Berj N. Ensanian KI3U <Ki3u@...>
·
#70093
·
|
Re: 7T11 Sequential/Random Problem
Hi Mike, Strange things in the dot pattern happen indeed in Random mode, but I don't remember a case of time-reversal. I think much depends on the repetition rate of your signal generator. I think the
By
Albert <aodiversen@...>
·
#70092
·
|
Re: Nuvistors.
Q203 may have developed more leakage over the years and will eventually have to be replaced. I'd look for a replacment just to be ready for when it does. Arden
By
KB6NAX
·
#70091
·
|
Re: 7T11 Sequential/Random Problem
Hi David, It's not an elongated dot. It's simply a small segment of the sine waveform. If you scroll through the scan positions, you will see that "dot" follows the shape of the sine wave. Therefore
By
Albert <aodiversen@...>
·
#70090
·
|
Re: OT XOR doesn't work as it should
I have seen them used though where profile was not a consideration. Tektronix of course early on had their own version with those low profile Teflon(?) insulated collets before they switched to
By
David Hess
·
#70089
·
|
Re: 7603 no trace
Hi Allow me to offer a different opinion on this isolation matter. I worked on a 7D13 with an isolated(floating) section this weeikend. I used my isolation gear so that I could tie my scope
By
Jerry Massengale <jmassen418a@...>
·
#70088
·
|
Re: TR502 7L13/14 etc Lemo connector
Hi! Thanks much for the information! It's in the archive now, so the next to search on this will find it. Would you care to share the distributor you used, and I'm almost afraid to ask, the price?
By
pdusel
·
#70087
·
|
Re: Power supply problem with Tek 2220
At least check the incircuit power supply electrolytic capacitors for ESR. If you don't have an ESR tester, buy one or build one. There is lots of ESR information on the web and also in the archives
By
Terry Gray
·
#70086
·
|
Re: 7603 no trace
Hello Magnus. I do have a piece of equipment like that , this is what it looks like http://www.tiptemp.com/products/1359/variac Can you please explain some more. How can I find out if it is isolating,
By
David Miles <bwex@...>
·
#70085
·
|
Re: Nuvistors.
Don Lewis wrote Fri, 20 Jan 2012 04:36:14 -0800 : " My old HP-130C scope has two 7586 Nuvistors in it, btw. " A really fine rig. I read somewhere the HP-130C is regarded by some as the last good
By
Berj N. Ensanian KI3U <Ki3u@...>
·
#70084
·
|
Re: 7T11 Sequential/Random Problem
Hi Albert, Pointing me to triggering was an excellent judgement call. I fiddled a bit with the bias controls on the various TDs and managed to get a stable display at some trigger levels, but it was
By
David C. Partridge
·
#70083
·
|