Re: New file uploaded to TekScopes
Right -- some of the Tek analyzers have a 3 dB pad in front of the mixer, and some have a protective Schottky clamp as well. Neither offers you any real guarantee of protection from mishaps but they
By
John Miles <jmiles@...>
·
#34986
·
|
Re: New file uploaded to TekScopes
By
monettsys <bni-4l1i@...>
·
#34985
·
|
Re: 067-1201-99
That's a TM-500 series plugin, and is not mentioned in Dennis Tillman's comprehensive list. Dave Casey
By
Dave Casey <dcasey@...>
·
#34984
·
|
067-1201-99
Does anyone have any idea what this is used for? From the -99 suffix, I know it was a factory unit as against one that was sold. It looks rather like it would plug into a 5000 series 'scope, or maybe
By
david_c_partridge <david.partridge@...>
·
#34983
·
|
Tek 922
Hello new to the group.? On my 922 I am having 2 problems.? Cant turn down intensity, measured volts to R412 and it is 7.5 instead of 8.? Low volt power supply is correct on all voltages. R412 is
By
Michael Hann <mchl_hann@...>
·
#34982
·
|
Re: 2711 lost tracking generator
Hi, When the tracking generator is installed in the 271x analyzers, it is immediately recognized by the CPU. I would take a close look at the interconnections between the power supply board (J4) and
By
Brian J. Henry
·
#34981
·
|
Re: New file uploaded to TekScopes
the SA to Only then, cap should
By
Joe Rooney <ikerooney@...>
·
#34980
·
|
Re: New file uploaded to TekScopes
TekScopes@... wrote: John, I recommended the setup AND the procedure, which includes setting the SA to max attenuation BEFORE connecting anything else and powering up. Only then, you can
By
Didier Juges <didier@...>
·
#34979
·
|
Re: [TekScopes2] Re: 7854 problems
Had the calibrator to ch1/Left, stable +/-2 div signal centered on the display. All other chanels where of. With best regards Tomas Larsson TL Engineering & Consultants Engelbrektsgatan 121 SE 506 39
By
Tomas <tomaslarssonse@...>
·
#34978
·
|
Re: 7854 problems
I have had this happen before. Setup the scope with a single waveform (i.e calibrator signal), make sure your timebase is beig triggered (near as I can tell, the acquisition doesn't happen until an
By
Dave Casey <dcasey@...>
·
#34977
·
|
7854 problems
Dear group. Started to play around with my newly acquired 7854. Ran into some problems directly. Havent had time to go through it yet, will obviously need to do that. This is what's happening. Analog
By
Tomas <tomaslarssonse@...>
·
#34976
·
|
Re: Interesting 547..........
Yes, it is a prototype. Specifically a unit numbered 09 of the B phase pre-production build (perhaps 10-20 units), this one assigned to ENGineering. Earlier in the process, A phase instruments were
By
Dick Ballard <ballardr@...>
·
#34975
·
|
Re: Interesting 547..........
Preproduction instruments were designated "A-phase" or "B-phase". These have an informal serial number that starts at 01. The B means that this is a B-phase instrument, not that it was made in
By
Dave Wise
·
#34974
·
|
Re: New file uploaded to TekScopes
Multilayer ceramic capacitors are becoming more and more common these days, up to about 100 uF, as replacements for conventional tantalum electrolytics. However, I'd be reluctant to use 10 uF in a
By
John Miles <jmiles@...>
·
#34973
·
|
Re: New file uploaded to TekScopes
Those are handy, but the DC isolator refers to a 10?f ceramic capacitor. I suspect that should be a monolithic, film or even a non- polarized electrolytic, but ceramic? ¨C John
By
John Rehwinkel <jrehwin@...>
·
#34972
·
|
2711 lost tracking generator
I am working on a 2711 that has lost its tracking generator. The inside factory label lists installed options 3-4. and indeed the TG output connector is present. when you press the DEMOD/TG button it
By
jminn699 <CMINN@...>
·
#34971
·
|
Re: Tek A6901 manual or circuit please
wrote: as "faulty". useful scope Schematics are only a few pages - I can make the scans. Contact me off list. /H?kan
By
zenith5106
·
#34970
·
|
Tek A6901 manual or circuit please
I just bought one of these which was accurately described as "faulty". Which it seems to be! Before I start pulling it apart does anyone have either a manual or circuit diagram they can share with me?
By
oldtestgear <philip.parsons@...>
·
#34969
·
|
Tektronix 475 Timebase Variable switch problem
I have a bent inner rod on the Var control/switch. When I rotate the Var, the switch on the board moves, because the long rod is bent, and it won't be long before the solder breaks loose. How can I
By
thepinkfloyd67
·
#34968
·
|
Busted 7613
So I have a 7613 here that is complete but has obviously seen better days. The scope powers on quietly but after a few seconds, the whole screen gets flooded green. Instensity/storage adjustments make
By
Dave Casey <dcasey@...>
·
#34967
·
|