Re: A problem filled FG507
If it's those gold PCB mount flat spring contacts used in the cam switches, the Tek approved way of cleaning them is with plain white paper. You don't want any residue left on them at all or you'll
By Jared Cabot · #177003 ·
Mystery Probe Accessory Grab Bag 'o Fun
I've been trolling the "pile of miscellaneous parts" auctions/sales on eBay in an attempt to cheaply bulk up my supply of consumable probe accessories, and I hit a few jackpots, but now I need some
By Jeff Dutky · #177002 ·
Re: 2236 Manuals
Jeff - Consider too, the 2246/A and 2247A which add live monitoring for voltage and time functions in the technician level 4 channel scopes (100MHz). >>>>>>>>>>>>>>>>>> Yes, if you skip ahead a
By benx618(g) · #177001 ·
Re: posts
Fewer; I had to check my spam folder to make sure I hadn't accidentally flagged the posts as spam again. -Dave?
By Dave Seiter · #177000 ·
posts
are the posting getting fewer or is my email on getting them.
By Mike Jaeger <mike.jaeger@...> · #176999 ·
Re: 2235 Horizontal Calibration Issue
The great thing about vintage test equipment (especially older Tek's) is there is so much details about their construction and schematics. Surprisingly schematic of U760 is also available. If you
By Ozan · #176998 ·
Re: 2235 Horizontal Calibration Issue
Even if 2235¡¯s were more available, I wouldn¡¯t buy one just for this. Not worth it... The horizontal A4 board if I found one, if the price was right, yes. I have plenty of other scopes. Is there
By Stephen · #176997 ·
Re: 2235 Horizontal Calibration Issue
Ozan, I¡¯m going to recheck all the voltages. Even those at Q770, Q780, and VR764. I¡¯ll report back.
By Stephen · #176996 ·
Re: 2235 Horizontal Calibration Issue
Ozan, Stephen, Sorry for mixing you two up. -- Jeff Dutky
By Jeff Dutky · #176995 ·
Re: 2235 Horizontal Calibration Issue
Hi, Yes, this is the first thing I checked. But they are... ??
By Stephen · #176994 ·
Re: New cable for Tek P6042 current probe?
There is no modern replacement AFAIK, it is unique to Tektronix. But I don't see why a new cable can't be made with modern things like flex heat shrink tubing and single wires. My 6042 stopped
By Snappy · #176993 ·
Re: 2235 Horizontal Calibration Issue
Hi Jeff, As Stephen wrote 2235 is his scope. He is unfortunately (or fortunately, Paris is very nice) in Paris so I don't know the availability of 2235s. I am hoping U760 is still good. Ozan
By Ozan · #176992 ·
Re: 2235 Horizontal Calibration Issue
Hi, I would check if the wires to the deflection plates are still properly connected to the CRT. Leo
By satbeginner · #176991 ·
Re: New cable for Tek P6042 current probe?
Hello Stefan where are you located I may have it, contact me off list via PM. By the way the 6042 suffers from flaky transistor sockets and very unstable DC offset. Kind Regards Jon
By Jean-Paul · #176990 ·
Re: 2235 Horizontal Calibration Issue
Hi Stephen, Yes, Paris would be a bit far :) In the pictures you are still getting the sweep right of mid point. U760 is pretty symmetric inside so I would expect any damage to distort the whole
By Ozan · #176989 ·
Re: A problem filled FG507
Hi Eric, You've got a problem with the capacitance multiplier somewhere (that's where you've been looking, I presume -- U1930 and U1940). That circuit is engaged only at the lower multipliers. The
By Tom Lee · #176988 ·
Re: 2235 Horizontal Calibration Issue
Jeff, It¡¯s not Ozan¡¯s scope, it¡¯s one of mine. I hope U760 is not dead... ? I just went to the Qservice site, and that A4 board is out of stock.
By Stephen · #176987 ·
Re: [dead tek 485] Can i fix it ? (newbie here)
Hi Jos¨¦, If you change the frequency from 1KHz to 50 Hz how change the screen? It seems also that it is a blanking trouble for retrace/stop sweep. Best regards Alain Nota: I didn't resist to
By Alain Mionnet · #176986 ·
New cable for Tek P6042 current probe?
Hello, I have been lucky to find a P6042 current probe with a fully functional coil and hall sensor. The only band thing is that the cable to the sensor was broken in at least 7 places. It is
By Staffan · #176985 ·
Re: 2235 Horizontal Calibration Issue
Ozan, Sorry to hear that U760 may be dead. The good news is that 2235's are common as dirt. You should be able to get a replacement fairly inexpensively, even if that replacement comes surrounded by
By Jeff Dutky · #176984 ·