Re: 2235 Horizontal Calibration Issue
Even if 2235¡¯s were more available, I wouldn¡¯t buy one just for this. Not worth it...
The horizontal A4 board if I found one, if the price was right, yes.
I have plenty of other scopes.
Is there
By
Stephen
·
#176997
·
|
Re: 2235 Horizontal Calibration Issue
Ozan,
I¡¯m going to recheck all the voltages. Even those at Q770, Q780, and VR764.
I¡¯ll report back.
By
Stephen
·
#176996
·
|
Re: 2235 Horizontal Calibration Issue
Ozan, Stephen,
Sorry for mixing you two up.
-- Jeff Dutky
By
Jeff Dutky
·
#176995
·
|
Re: 2235 Horizontal Calibration Issue
Hi,
Yes, this is the first thing I checked. But they are... ??
By
Stephen
·
#176994
·
|
Re: New cable for Tek P6042 current probe?
There is no modern replacement AFAIK, it is unique to Tektronix. But I don't see why a new cable can't be made with modern things like flex heat shrink tubing and single wires.
My 6042 stopped
By
Snappy
·
#176993
·
|
Re: 2235 Horizontal Calibration Issue
Hi Jeff,
As Stephen wrote 2235 is his scope. He is unfortunately (or fortunately, Paris is very nice) in Paris so I don't know the availability of 2235s. I am hoping U760 is still good.
Ozan
By
Ozan
·
#176992
·
|
Re: 2235 Horizontal Calibration Issue
Hi,
I would check if the wires to the deflection plates are still properly connected to the CRT.
Leo
By
satbeginner
·
#176991
·
|
Re: New cable for Tek P6042 current probe?
Hello Stefan where are you located I may have it, contact me off list via PM.
By the way the 6042 suffers from flaky transistor sockets and very unstable DC offset.
Kind Regards
Jon
By
Jean-Paul
·
#176990
·
|
Re: 2235 Horizontal Calibration Issue
Hi Stephen,
Yes, Paris would be a bit far :)
In the pictures you are still getting the sweep right of mid point. U760 is pretty symmetric inside so I would expect any damage to distort the whole
By
Ozan
·
#176989
·
|
Re: A problem filled FG507
Hi Eric,
You've got a problem with the capacitance multiplier somewhere (that's where you've been looking, I presume -- U1930 and U1940). That circuit is engaged only at the lower multipliers. The
By
Tom Lee
·
#176988
·
|
Re: 2235 Horizontal Calibration Issue
Jeff,
It¡¯s not Ozan¡¯s scope, it¡¯s one of mine.
I hope U760 is not dead... ?
I just went to the Qservice site, and that A4 board is out of stock.
By
Stephen
·
#176987
·
|
Re: [dead tek 485] Can i fix it ? (newbie here)
Hi Jos¨¦,
If you change the frequency from 1KHz to 50 Hz how change the screen?
It seems also that it is a blanking trouble for retrace/stop sweep.
Best regards
Alain
Nota: I didn't resist to
By
Alain Mionnet
·
#176986
·
|
New cable for Tek P6042 current probe?
Hello,
I have been lucky to find a P6042 current probe with a fully functional coil and hall sensor. The only band thing is that the cable to the sensor was broken in at least 7 places. It is
By
Staffan
·
#176985
·
|
Re: 2235 Horizontal Calibration Issue
Ozan,
Sorry to hear that U760 may be dead. The good news is that 2235's are common as dirt. You should be able to get a replacement fairly inexpensively, even if that replacement comes surrounded by
By
Jeff Dutky
·
#176984
·
|
Re: 2236 Manuals
Siggi,
Yes, if you skip ahead a few years you start getting the options on the 2445/2465 to do all kinds of neat things (multimeter, counter/timer, word recognizer, and TV features) but I was
By
Jeff Dutky
·
#176983
·
|
A problem filled FG507
I am working on 2 Tektronix function generators. An FG 507 and a FG 502 both 2 Mhz. The 507 is on the bench currently and I am having a weird issue with the frequency selectors. Everything above 100X
By
Eric
·
#176982
·
|
Re: 2236 Manuals
kim.herron@...> wrote:
Well, the CT option for the 2445/2465/2467+ gives you a proper counter.
This is in addition to cursor measurements that come with the basic scope.
The option also
By
Sigur?ur ?sgeirsson
·
#176981
·
|
Re: 2236 Manuals
Hey Siggi!
That was my point. I don't need or want to be a computer
programmer to see a measurement value. The 2236
does things right there and no settings need to be
changed. As I also
By
[email protected] <kim.herron@...>
·
#176980
·
|
Re: 2235 Horizontal Calibration Issue
Ozan,
I will make new measurements later on.
I don¡¯t ??think?? my probe tip touched anything, I was extremely careful. But
who knows....
In any case, if it did, U760 is probably partially
By
Stephen
·
#176979
·
|
Re: [dead tek 485] Can i fix it ? (newbie here)
Hi Jose,
I will send you the expected A-gate picture by private message, you can post it in your album if you want.
In your
By
Ozan
·
#176978
·
|