Re: 577 retrace problem
Hi Fred, Make a note to yourself - Craig is much smarter than me for several reasons: He knew the answer right away; He was able to describe it in one paragraph; He had a better way to test this with
By
Dennis Tillman W7pF
·
#152067
·
|
Re: Tek 2465B Bezel Removal
Any digital scope is a sampling system, so it looks at a waveform, does an average during the sample period, and then ignores the signal to the next sampling period. Pretty much as long as you sample
By
Harvey White
·
#152066
·
|
Re: Tek 475 Repair
hello all similiar hi my usual problem with the tektronix 475 voltages as of now: 50v 33 v 50v a reg 67 105-160v 132 + 15v 5.53 5v 3.25 -15v -8..8 -8v -5.12 110v 86.4v What could be the cause? if you
By
Roberto
·
#152065
·
|
Re: Tek 2465B Bezel Removal
Okay, I think the analog would be more useful possibly in trouble-shooting, but I am so experienced in the TDS3000 series, that I love trouble-shooting with it, plus I know the equipment so well that
By
David Kuhn
·
#152064
·
|
Re: Tek 2465B Bezel Removal
They aren't that bad. They can do well. Not really useless, IMHO. Probably is
By
Harvey White
·
#152063
·
|
Re: Tek 2465B Bezel Removal
Craig, Thank you kindly for those detailed instruction, which I have printed out. Perhaps later today, I will follow them and get that puppy cleaned out and generally look inside for cap leakage. Dave
By
David Kuhn
·
#152062
·
|
Re: Tek 2465B Bezel Removal
" The 2465B does (should!) have measurement cursors for time and/or amplitude but you have to enable them to see them. Nice dumpster find! " Yea, I found them, before putting it aside this morning to
By
David Kuhn
·
#152061
·
|
Re: Tek 2465B Bezel Removal
The knobs don¡¯t have to come off. This is how I do it all the time. I usually take the case off when doing this but the scope needs a front cover which you may not have. But it if you set the face
By
Craig Cramb
·
#152060
·
|
Re: Tek 2465B Bezel Removal
There is a plastic trim strip on the top of the bezel that snaps off revealing some additional screws. Manuel
By
Manuel Maseda
·
#152059
·
|
Re: Tektronix 067-0625-00 Peak to Peak Detector Battery
Same thing with logic analyzer probes, scope probes, and anything in general. Ran into a bunch of P6201 active probes that were "decommissioned" by cutting of the 40 dollar LEMO connectors. I
By
Harvey White
·
#152058
·
|
Re: Tek 2465B Bezel Removal
Hi Dave, The 2465B does (should!) have measurement cursors for time and/or amplitude but you have to enable them to see them. Not sure the exact buttons that do that but it should be easy enough to
By
n4buq
·
#152057
·
|
Tek 2465B Bezel Removal
I got a 2465B, 400MHz, while dumpster diving a while back. It seems to work perfect. I do not have a lot of use for an Analog scope, (especially w/o GPIB) but if I decide to sell it on EBAY, or even
By
David Kuhn
·
#152056
·
|
Re: 425 Mil vertical module needed....seeking
Hi Jack, Bert Haskins... he's replied to your topic, see msg reference below. /g/TekScopes/message/152031 Most of his message is quote from previous messages... And his reply is a two
By
Fabio Trevisan
·
#152055
·
|
Re: 577 retrace problem
On Thu, Nov 1, 2018 at 08:31 AM, Craig Sawyers wrote: > > > 2) John's final conclusion is as follows: The fact that this separation of > traces happens mostly at > > the > > part of the collector sine
By
Albert Otten
·
#152054
·
|
Re: 577 retrace problem
Hi Fred, I glad you asked about this because at times I find this effect quite annoying and at other times it seems like all the curve tracers I have owned (2 x 575s, 1 x 576, 5 x 577s) have displayed
By
ef804s tubes
·
#152053
·
|
Re: Tektronix 067-0625-00 Peak to Peak Detector Battery
and I do still offer it. For details please refer to < http://www.perdrix.co.uk/SG504Head/index.htm> where you'll find full details of the design, construction and test results. Dave
By
David C. Partridge
·
#152052
·
|
Re: My 2465B has arrived + A5 Board leaky caps cleanup
Alex, Correction: the BNC jack is labled Word Recog Out. Manuel
By
Manuel Maseda
·
#152051
·
|
Re: My 2465B has arrived + A5 Board leaky caps cleanup
Alex, If the scope has the optional CTT board then it is very simple with your serial number scope to enable the external frequency input option (1E) by simply moving the coax cable for rear BNC jack
By
Manuel Maseda
·
#152050
·
|
Re: 577 retrace problem
The way to test this is to wire up a cascode arrangement of two transistors, and curve trace that. Since the whole rationale of a cascode is to mitigate the effects of Ccb, the looping should
By
Craig Sawyers <c.sawyers@...>
·
#152049
·
|
Re: Tektronix 067-0625-00 Peak to Peak Detector Battery
that?) What receivers do when a company goes bust is make a pile of electronics to sell, and put all cables or anything that looks like a cable, in a large bin and sell that as a single lot. Since a
By
Craig Sawyers <c.sawyers@...>
·
#152048
·
|