Re: 2465B low serial - checksum & recapping
Jon,
many thanks but: 1) I have hopefully a good capture video of all the CAL 02 values. 2) I found a lab that claims they have all the required equipment to fully calibrate it I was wondering: a) if there is a method to be certain that the values I captured in video can be checked against the checksum(no GPIB card). I have found a source code for the spiral checksum but not sure how to apply to the data. Not much of a cryptologist, but still can code something. b) assuming I will make recalibrate it in the lab (still deciding about it) I would like to recap the scope prior to recalibrate it. So I am looking for a BOM for Digikey or Mouser. a reasonably priced kit (price+customs and so on, shipped to Italy) can be a viable option. Hope it is more clear. -- Giuseppe Marullo IW2JWW - JN45RQ |
tektronix 2712 sa
Dear tektronix fans
To introduce myself Hubert ON6JZ living in Belgium and an electronics repairer for 45 years I now have a tektronix 2712 on the table that does not work. It has been idle for over a year. At startup it gave all kinds of error messages , after replacing both batteries on the digital board and on the digital option board it seems to start up normally , But I get no response from any button and the encoder does nothing either All supply voltages are correct and viewed cleanly with a scope I replaced all the smd electrolytics on the sweep board and on the digital storage board No result On the screen I get an image of out of memory. Does anyone have any tips on where I can look for this error? Thanks in advance Hubert |
Re: 2465B low serial - checksum & recapping
What do you do with the values read from CAL/EXEC function. is there a way to enter/change them?
I am asking as I have a 2465 as well that just had 04 10 which is describes by Tektronix as just out of cal (guessing old data or checksum fails. ER1400 can hold data for 10+ years) but TBH the cost of calibration if you dont have the very specialised TMG is not worth it for a scope this age (my opinion as you can by newer versions for 3-500GBP) or go crazy old skool and aim for 4xx series IF BW is the issue. I am for fun experimenting with reading the data out of the ER1400 (potentially replacing is if it is bad - I got like 10 spare ones). I am not too fuzzed about accuracy as I have digital never scope as well if needed). Just curious to understand the logic behind what is stored in ER1400, checksums, etc and if it can be trigged into thinking it is calibrated and don't fail on selfcheck. Cheers. |
2465B low serial - checksum & recapping
CHECKSUM
I would kindly like to know, assuming I dumped correctly the CAL 02 values, if there is a sound method to verify the checksum for my scope before fiddling with the battery. Any pointer before I get mad with X-Way forensics editor? I found a guy that could re calibrate it for 300EUR (maybe 250, we have two scopes) so I could just avoid the hassle to change the battery myself and/or switch to FRAM. It seems it could even be a reasonable price, I don't know. RECAPPING Of course, if I have someone to recalibrate it, I may well think of recalibrating it AFTER recapping. Is there any current BOM for Digikey/Mouser available? TIA. -- Giuseppe Marullo IW2JWW - JN45RQ |
tektronix 2712
Dear tektronix fans
To introduce myself Hubert ON6JZ living in Belgium and an electronics repairer for 45 years I now have a tektronix 2712 on the table that does not work. It has been idle for over a year. At startup it gave all kinds of error messages , after replacing both batteries on the digital board and on the digital option board it seems to start up normally , but I get no response from any button and the encoder does nothing either All supply voltages are correct and viewed cleanly with a scope I replaced all the smd electrolytics on the sweep board and on the digital storage board No result On the screen I get an image of out of memory. Does anyone have any tips on where I can look for this error? Thanks in advance Hubert |
Re: DO I NEED TO CHANGE THE 3.7 VOLTS BATTERY IN TEKTRONIX 2467 WHEN IT READS 3.7 VOLTS
If anyone is interested in old GPIB adapter hardware and has a USA mailing address, I can offer for free:
- HP 27209-60001 GPIB 8-bit ISA card, or - IOTech Micro488/EX Bus Controller (this is a bi-directional RS232<-->GPIB gateway), w/power adapter and manual Either (or both, if you can use both), would be for the cost of postage on a USPS flat-rate box. You would email me a label. Either can be used to do the cal backup, and communicate with other GPIB/HPIB/IEEE-488 equipment. They're not doing anything here except collecting dust for years. Please contact me off-list if interested. -mark |
Re: DO I NEED TO CHANGE THE 3.7 VOLTS BATTERY IN TEKTRONIX 2467 WHEN IT READS 3.7 VOLTS
I run Linux with the linux-gpib driver, which from personal experience works fine with the NI GPIB PCI card and the Keysight 82357B.
toggle quoted message
Show quoted text
For windows, I'm certain other users can jump in with some recommendations. Steve Hendrix, a user on this group, has a product called the KISS-488, but I have not used it: . There are a number of open source GPIB (aka IEEE-488) adapters, such as the AR-488, if you are looking for something more home-brew. If you are asking specifically about the cable, I would recommend getting a used HP 10833A/B/C/D cable. They come in various lengths depending on the suffix letter. Note that GPIB functionality is very limited on the 2445/2465 (plain)/A/B and 2467 scopes and only provides basic control and can also return measurement values. It does NOT allow you to download a copy of the displayed waveform, if you are expecting that. So, if you have a GPIB interface laying around, it's handy to use for calibration backup, but I probably wouldn't go out of my way to get one just for backup. For the software on the PC, you just need to be able to send a command and capture the output to do a cal backup. All adapters have this capability in their host software. No one has written any special application for backing up these scopes, as far as I know. -mark On Wed, Apr 9, 2025 at 09:40 AM, Alex wrote:
|
Re: DO I NEED TO CHANGE THE 3.7 VOLTS BATTERY IN TEKTRONIX 2467 WHEN IT READS 3.7 VOLTS
On 2025-04-09 9:40 AM, Alex wrote:
I know there are those rather pricey HP GPIB to USB adapters floating around ebay for $100 and plus.Well, my KISS-488 is one of those "pricey" adapters, at $129 single piece via my www.hxengineering.com, but it does way more than just USB. USB/serial at 115.2 KBPS, Telnet, HTTP (any standard browser), SNTP (sets a local clock, to timestamp data it records and graphs), ICMP (so you can ping to confirm connection), and TFTP (for firmware updates). And I've recently added some "quantity purchase" options as well. Best of all, it's as close to obsolescence-proof as I could make it - no PC side drivers to load, indeed not even tied to PC, as one of my beta testers uses it with an Apple. Just a lot of standard protocols that are well establish and not likely to go away soon. Others have suggested the roll-your-own approach, but I'm here to tell you it takes a lot more than it first appears, and I'll never make enough on it to justify the amount of time in it. But I mode it for my own use and decided to share it to help keep these old boat anchor precision instruments alive. Pardon the sales pitch, but I only mention it when directly applicable to solve a list member's need. I'll shut up now, and any queries should be taken offline directly to me at SteveHx@.... Steve Hendrix |
Re: DO I NEED TO CHANGE THE 3.7 VOLTS BATTERY IN TEKTRONIX 2467 WHEN IT READS 3.7 VOLTS
Yes, it also works with the 2465 (meaning not A or B versions).
toggle quoted message
Show quoted text
With the 2445 or 2465, you will get 200 calibration values returned instead of 256. If you don't have any options installed, I believe it will only return 100 values because the second EEPROM (EAROM) resides on the options card cage which is only installed if you have options. -mark On Wed, Apr 9, 2025 at 04:53 AM, maurit wrote:
|
Re: DO I NEED TO CHANGE THE 3.7 VOLTS BATTERY IN TEKTRONIX 2467 WHEN IT READS 3.7 VOLTS
Just for completeness of the information, what kind of cable is needed to do the GPIB backup into a windows PC?
I know there are those rather pricey HP GPIB to USB adapters floating around ebay for $100 and plus. Would that be the correct cable type? And what software is needed in the PC? |
Re: Advice on 577 Resurrection
On 8 Apr 2025 5:17 pm, Jean-Paul wrote:
Dale, Mia culpa on the TM faux pas....Jean-Paul - It is a far-too-frequent error. The patented precision track plating and wiper button design make the Variac significantly better than other brands that I have used. If you have not seen it the patent, assigned by Smiley Gilbert to GR, is at: -- Dale H. Cook, GR/HP/Tek Collector, Roanoke/Lynchburg, VA |
Re: 310A Power Transformers - Sudden Intermittent Operation on 204 Volt Winding/-150 Volt Supply
John,
Thanks for the information. I had not had the CRT problem - yet. There's always plenty of time for additional problems to accrue! Not to be snarky, but did your filament transformer have at least a 5,000 Volt rating? I know that the CRT heater voltage is elevated quite a bit to prevent H-K breakdown, and that is why I have been saving just such a 6.3 Volt transformer for over thirty years. As for my 310A troubles, I had wondered if the insulating varnish might be breaking down, although I have no transformer information or specifications that could confirm this by DC resistance readings of the windings. The confounding thing is that this came on so suddenly and to both of my 310As to the point that I would put the heat theory in second place more because of the infrequency of use of both of these 'scopes. Perhaps, though, infrequent use was the cause of the trouble by leading to a high inrush current to form those damned electrolytic capacitors (I am gradually switching to film types where possible. ). I had blown a metal film 10 ohm resistor, R601, at the input of the -150 volt power supply two or three years ago and had attributed it to a poor choice of resistor type in that position in the circuit, but perhaps it was more than just the type. The carbon film types that I put in are still working. |