P6610 physical measurement amplifier
In my collection of probes, I have a P6610 physical measurement amplifier and three P6610 pressure transducers. I don't have any documentation and a search of the usual sources has come up empty. Wondering if anyone here knows anything about this probe or, better yet, has some documentation they would be willing to share.
Thanks - Bill |
Re: Old (mostly) Tek Scopes for Sale in Schenectady
On Tuesday 04 March 2025 11:43:29 am taitny via groups.io wrote:
The Edison Tech Center is clearing out it's collection of old scopes and test equipment.Some of us don't do facebook... From what I can see, it looks like they want to get rid of that stuff as one whole lot. :-( -- Member of the toughest, meanest, deadliest, most unrelenting -- and ablest -- form of life in this section of space, ?a critter that can be killed but can't be tamed. ?--Robert A. Heinlein, "The Puppet Masters" - Information is more dangerous than cannon to a society ruled by lies. --James M Dakin |
tektronix 577 curve tracer polarity positioning fail
Hi,
the spot is always coming vertically outside the screen, when I change the polarity (about one graticule outside). I have tested the VertPos Adj pot but it is not enough to get the points back in the correct vertical position. any suggestions? thank you, |
Re: 2430A no display
You know how sometimes the Universe just sends you signals, perhaps to remind you that you are on the right path?
Well, this morning I received a phone call from the man who often supplies test equipment. He has a friend who buys up the assets of failed companies and when test stuff appears, I generally get a call. They just want rid of it and often pretty much give it away. I've bought too much to remember, however two items which spring to mind are spectrum analyzers, a HP 8569B for (the equivalent in Brazil) less than 20 Dollars and a Tek 492 for 35 Dollars. Both with failed PSU's and both fully functional following simple repairs. Insane! Although I mustn't forget the 'dead' (yet calibrated) Fluke 289 for 40 Dollars which only had a bad battery connection and is now my most accurate DMM. Anyways, I digress... This morning, he rings me up to offer me two scopes for 50 Dollars. Would you believe it that one was a 2430A!?!? Lol The other was/is a TAS 465 which he said was missing a board, but looking at the manual and a teardown, it appears to be complete. The problem being that it only displays a stationary 'dot' in the middle of the display. So, opening up the new 2430A, revealed that on the top board, two tantalums had totally burned up, ironically including the 2.7?F one mentioned earlier in this thread.. Seemed reasonable to just switch the board from my blurry 2430A and sure enough the 'new' scope came to life, displaying the diagnostic menu et al. Unsurprisingly it has various 'FAILS' however, it now gives the opportunity to switch boards and Hybrids in order to hone in on any problems. The TAS 465 shall have to wait. Addendum... The TAS 465 (which had been left plugged in but off) just went pffffftah! and dumped out a whole load of smoke. Guess I now know where to start.. :) James |
Tek 2236 Control Button Error
Recently my Tek 2236 began giving a "Control Button Error" message, occasionally at first and now more regularly. Exercising the buttons does not seem to clear this. I ran the CTM diagnostic and everything passes except reading the 1X/10X CH1 sense ring, always indicating "P0" even when the ring is grounded (I don't know if it ever did sense correctly, as I generally used non-encoding probes anyway). In the diagnostic, it reliably reads the positions of all other switches, in particular indicating the push button positions solidly, no glitches seen in the 1/0 transitions in the diagnostic display.
Sometimes with no input I get the "OUCH" message on CH1 volts (even with the input set to ground). Otherwise, all of the CRT display functions appear unaffected. When the CTM is working, everything works in the alphanumeric display, when not, I get the scrolling "Control Button Error" message, nothing works in any button configuration. Anyone have any thoughts on this? I have several Tek scopes, analog, full digital, storage (for a 5L4N) and a 4 channel. However the 2236 is my favorite for general bench work. I miss the built-in frequency counter... |
Tektronix 2712 Amplitude Normalization Fail
Hello I have a 2712 that i picked up “parts only” on eBay. I replaced the two button cells and it works well aside from failing two Amplitude Normalizations.
BW Filter Ampltd (Lin) FAIL Preamp & Det Gain FAIL Wondering if anyone can point me in the right direction so I can fix it. |
Re: 2430A no display
James,
Likely the resistors to the C and B of Q145, Q152 and Q269 collector only are bad. The originals are stressed. Use 1W types. These are the same problem in the 24x5/7 series. Even if they test alright, they could be bad in operation. Get resistors physically larger to take the higher voltage drop. Ones about 10mm long work fine. Mouser has a wait of 12 weeks for 442,000 ohm resistors. A pair of 1/2W 221,000 ohm resistors in series will work. Mark |
Re: [HP-Agilent-Keysight-equipment] I need a new/used lab computer
Looks like he needs a PCI slot for gpib card. Would have to go to USB to GPIB if he went w a laptop.
toggle quoted message
Show quoted text
On Mar 6, 2025, at 15:27, Harke Smits via groups.io <yrrah@...> wrote: |
Re: I need a new/used lab computer
Well, I was hoping to get something quickly to do some experiments with the PS5004 power supply plug-ins I just bought recently. Rather painful to adjust a 20 V supply in 500 uV increments! But you are more than welcome to stop by my house. I will be on vacation from Th 3/13/25 to F 3/21/25, but a visit after that would be great. I’m right off the 5 San Diego freeway.
toggle quoted message
Show quoted text
Thanks! Jim On Mar 6, 2025, at 12:59?PM, Tom Lee via groups.io <tomlee@...> wrote: |