Keyboard Shortcuts
Likes
- TekScopes
- Messages
Search
Re: 1 Peter Keller Book for Wichita KS held in USPS Seattle Network Distribution Center
Dennis,
Received book, guess just have to have extra patience when dealing with the Postal Service. Thank you for all of your extra effort. Eric, yes we are definitely in the same county. I¡¯m glad to see there are other Tek fans locally. Too bad we don¡¯t have access to local electronic stores as other members in the USA have in their neighborhoods. Craig |
Status Update on Canada bound Peter Keller Books
I got at least one of the Canadian tracking numbers mixed up with another
Canadian tracking number. These are the correct tracking numbers and their destinations and/or delivery status LH127124103US Delivered North Vancouver BC LH127125165US OAKVILLE, ON LH127125982US HAMILTON, ON LH127126740US Delivered Edmonton Alberta LH127128207US Cleared Customs Jan 17; Arrived in Burnaby BC mail facility Jan 19; In transit to destination BEACONSFIELD, QC Jan 19. Dennis Tillman W7pF |
Re: Peter Keller's books are going VIA AIR MAIL
My copy to Norway was delivered today. Much pleased with the quality of the
toggle quoted message
Show quoted text
book! BR. Thomas. ons. 20. jan. 2021 kl. 02:14 skrev momemeca <momemeca@...>: Hello Dennis, --
With Best regards, Thomas S. Knutsen. Please avoid sending me Word or PowerPoint attachments. |
Elastomer Switch / HYPCON Contact Cleaning 067-0587-02 Standardizer
Hello all!
I've got a 7000 Series Standardization Plug-In 067-0587-02 that is acting strange. Sometimes the Gain setting on the TEST switch will show a compressed set of lines instead of the correct 1 line per division and the Aux-In is distorting the waveform. I swapped the Aux-In first Hybrid IC U350 for one out of my 7904A and no change was observed. I removed and re-installed the 2nd Hybrid U390 and the waveform was better but still distorted. Due to the low use of the plug-in from the seller I purchased it from I suspect that the contacts in the HYPCON's and the TEST switch contacts may need cleaning. There is a cleaning procedure in the manual I can follow but I was wondering about the application of DeOxit Gold to the contacts? Thanks in advance! |
Re: Tektronix 492BP
On Fri, 22 Jan 2021, Mike Yepes wrote:
Does it switch to frequency bands higher than 5? Bands for use with external mixers start with Band 6. Hi, can Anyone help how to get higher frequency displayed on this?--- * * KSI@home KOI8 Net < > The impossible we do immediately. * * Las Vegas NV, USA < > Miracles require 24-hour notice. * * |
Re: I built a TM500 mainframe tester, and updated the design. Someone might find this useful?
Bruce, regarding your question about compatibility of this tester with TM5000 mainframes, I believe it should work. As I recall, the TM5000 mainframes can run TM500 plug-ins, but the reverse does not work - TM5000 plugs can not run in TM500 frames, and I believe they are mechanically keyed to prevent engagement.
All the pinouts for connections to the DC supplies, AC windings, and pass transistors are the same*. The main functional difference would be interpreting the tester's response to the DC supplies. The TM5000's regulated supplies were designed to provide just above the worst-case bottom of ripple (BOR) of the TM500's rectifier/filter outputs. So, any TM500 plug installed would see only the minimum value of input DC, and run more efficiently. Plugs that make their own supplies from the AC windings would run about the same in either frame type. So, if the tester is looking for the higher average DC voltages of TM500, it may report that it's too low in a TM5000, while in reality, it's just right. *TM5000 has an additional signal indicating valid power on state, on a pin that was unused in TM500. Ed |
Re: Tek 4041 GPIB Controller
Gary, Sorry to hear that - I thought you had your DDU repaired and that you booted from your DDU instead of the tape drive. I don't suspect the 4041 tape drive, although I would recommend using isopropyl alcohol on a swab to clean the head, and try the tapes again. It appears the plastibands are only a temporary drive belt solution in the tape cartridge - and they will stretch as the drive rewinds the tape to the beginning before it can find any file. This is the Amazon link I used to get 4.25 inch plastibands: It is pretty easy to open the tape cartridge and replace the plastiband - the 4041 operators manual page 5-6 describes tape cartridge respooling with photos on page 5.7. You don't need to respool the tape to replace the plastiband - just lift the plastiband off the white belt wheels and capstan and put the new plastiband on starting with the capstan and finishing by pulling the plastiband over the white belt wheels. Then I use a bamboo chopstick to pull the belt away from the takeup reel with the least tape and tighten the tape by rotating that reel with a finger, then release the belt onto that reel. I then pull the cover back where the tape head touches the tape and push gently with the chopstick to check the tape tension - the tape should deflect 1/10 of an inch or so, but not 1/4 of an inch. Then put the cartridge cover back on and fasten the screws and the tape should now work. |
Re: [dead tek 485] Can i fix it ? (newbie here)
At the back of the scope there is a BNC marked as A-gate. While applying your sine wave to channel 1, triggering on channel 1, connect A-gate to channel 2. Pick "chop". Move X-axis to see the beginning of waveforms. You should not see the rising edge of the A-gate. Similarly if you look at A-sweep (available at the BNC back of the scope), you should see a linear ramp starting from the beginning of the trace. If you can see some portion of the A-gate while it is low or rising, blanking may have a problem. If A-gate is OK but ramp looks strange then could be something with the ramp. I have a 485 and tried this, I can send you the screen shots. Jittery waveform needs to be debugged separately. If you have another scope look at A-gate and the input signal at the same time to see if A sweep always starts at the same point of waveform. You should also try external trigger (BNC at the right bottom) feeding same signal to both Ch1 and "Ext Trig" and choosing Ext (start with Ext/10 if you are applying 5Vpp). Ozan |
Re: TEK465 Horizontal trace
Thanks for all of your help. I have spent way more time and I'm out of my
element and another O'scope for around $100 looks real attractive. At least this one is a parts source. I'm returning it to my friend who is still looking for a working O'scope. I'll keep monitoring the Group. Best Regards, Wes Texarkana, AR |
2236 Manuals
Is Shawn (KJ7MX) on here?
I'm asking in reference to the eBay listing for printings of the 2236 manual: Seems the original Tek manuals for 2236 are a bit difficult to come by, so I'm considering purchasing the above. I'm curious which version of the manual it is. There are several listed on the Tek Wiki. My SN is 017799 so I think relatively early. I would prefer having the correct manual for this SN. Thanks, Dave |
Re: Tek 4041 GPIB Controller
Monty: If only the engineers at Tektronix had created a boot ROM that was
toggle quoted message
Show quoted text
not erasable with age. My system is completely dead if I cannot run the AUTOLD from the tapes. None of my 3 tapes will work with my system. I am going to try to dig up my other 2 tape drives this weekend and do some swapping to try and get this 4041 thing up and running. When I built up my 2 Heathkit H8's back in 1977, I never had the slightest difficulty in using them to the fullest. At my old age, I am losing interest in all of this technical trouble. I need to be at peace. Gary On Thu, Jan 21, 2021 at 5:30 PM Monty McGraw <mmcgraw74@...> wrote:
I have spent the last couple of weeks with the EZ-TEST Generator (Volume --
Gary Robert Bosworth grbosworth@... Tel: 310-317-2247 |
Re: [dead tek 485] Can i fix it ? (newbie here)
Jose,
it looks like the beam is being unblanked before the sweep starts. Maybe the Z-axis amplifier has a problem? Or maybe the trigger circuits? Maybe some interaction between the two? That vertical bar you see on the left is the input signal without a sweep signal. That should be hidden by the Z-axis amp squashing the beam intensity during the retrace and before the trigger arms and triggers, but clearly it's not working correctly in your scope. -- Jeff Dutky |
KiCAD 6 is coming shortly
walter shawlee
A big milestone is coming this spring for KiCAD (schematic/PCB software).
this new version is a very powerful tool, and 6 adds microwave/RF layout features and a lot of other goodies. For everybody that has groaned over the initial cost and ongoing support cost of other eCAD tools this can be important news. If you are unable to afford the big seat cost of altium/Orcad, you may really want to look at this open-source tool. it is multi-platform (MacOS/Win/Linux) and free, with huge library support from Digikey and Mouser. CERN is the driving and coordinating group for this in europe, and is well funded long-term. The software is already 30 years old. Here's the latest 6 update info: Just passing it along, as coupled with the huge security and cost benefits of an OS like Ubuntu, it can really help you deploy a lot of capability and reliability for virtually no cost, whether you are a home user or company. I have used most eCAD tools (including KiCAD), and the new changes really make this look appealing to me. If as a Windows user, you really miss the once free eCAD tools that used to be available, here's a chance to get a truly professional grade tool in an affordable way. If you add in LTspice, you have a great engineering suite for free. the home KiCAD site is here: all for today, hope everybody there is well and safe, walter walter2 -at- sphere.bc.ca sphere research corp. |
Re: 2235 Horizontal Calibration Issue
On Mon, Jan 18, 2021 at 10:51 AM, Ozan wrote:
Hi, Base of Q770 reads +6.090 VDC, while the base of Q780 reads +6.081 VDC However, the cathode of VR764 reads high a +5.135 VDC.... |