Re: 2247A PSU Troubleshooting
Nick,
I replaced more than that on my 2246A supply. For the pain to remove the power supply, I thought it would be worth it. I may had others that were leaky, I don't recall. I still have the old ones stashed away somewhere, I looked to see what I replaced, but I didn't find them. I thought it may be helpful to you. NielsenTelecom |
Re: 2230 display distortion in the first quadrant
You have a damaged CRT.? Most likely from being dropped.
toggle quoted message
Show quoted text
Regards On 3/22/2019 10:46 AM, peterp@... wrote:
Hello all, I just got a 2230 scope from the (in)famous website to help me with some vacuum |
Re: Tek 547, 545a, and R561B for sale near me
01950
On Sat, Mar 23, 2019 at 2:03 PM Daniel Koller via Groups.Io <kaboomdk= [email protected]> wrote: Where are you? (zip code?) |
Re: Tek 547, 545a, and R561B for sale near me
Where are you? (zip code?)
toggle quoted message
Show quoted text
? Dan On Saturday, March 23, 2019 1:59 PM, David Berlind <david@...> wrote:
Hey all.. spotted these 3 beauts for sale near me. Don't know the seller. But it's very close to me. Asking price for all 3 is $125. There's an extra 3A74 plug in that goes with the bunch. I have facilitated purchases and shipping for people in this group before (as some will attest to). However, I've yet to ship a Cadillac. |
Tek 547, 545a, and R561B for sale near me
Hey all.. spotted these 3 beauts for sale near me. Don't know the seller. But it's very close to me. Asking price for all 3 is $125. There's an extra 3A74 plug in that goes with the bunch. I have facilitated purchases and shipping for people in this group before (as some will attest to). However, I've yet to ship a Cadillac.
|
Re: 2230 display distortion in the first quadrant
Hello Peter,
it looks like a magentization of the right upper corner of the magnetic shield. You should de-gauss it. Best regards Joerg peterp@... schrieb: Hello all, I just got a 2230 scope from the (in)famous website to help me with some vacuum --- Diese E-Mail wurde von Avast Antivirus-Software auf Viren gepr¨¹ft. |
Re: 2247A PSU Troubleshooting
I removed 8 diodes marked ZS last night and will order replacements today.
toggle quoted message
Show quoted text
Will report back with results. Thanks again for all the help so far Nick On Fri, Mar 15, 2019 at 9:37 AM <tekscopegroup@...> wrote:
On Thu, Mar 14, 2019 at 03:57 PM, tom jobe wrote:There are about 17 one amp ultra fast diodes that are used to rectifyIf they are marked ZM or ZS they are well known to get leaky. Replace |
11801 extender card
I want to investigate the possibility of replacing the 1.4 ps jitter clock with a modern device with sub ps jitter. As there is no component level documentation that I know of, doing this will require probing the running system.
Hence my search for an extender card. Does anyone know of a Tek part number or a source for a card? I'd design one, but I don't know how to use any of the PCB design tools and already have my hands full trying to master FPGA DSP design using Vivado and Quartus. Thanks, Reg |
2230 display distortion in the first quadrant
Hello all, I just got a 2230 scope from the (in)famous website to help me with some vacuum
tube ham radio equipment and it came with a fault. Here are some pictures and a short movie that show the fault: Both channels display correctly when the signal is in the lower half-plane of the display. As the displayed signals are moved to the upper half plane their part that falls in the first quadrant (upper right hand fourth of the display) distorts practically identically when each channel's signal is in the same position vertically. I searched the group and found a thread about an issue that may be related to mine. Unfortunately, the details are greek to me :-) Here's the old posts: /g/TekScopes/topic/7647928#70205 /g/TekScopes/message/71388?p=,,,20,0,0,0::relevance,,2230+Displayed+signal,20,2,0,7648113 Also, if anyone has any leads to repair services in New Jersey please let me know. I also have a 2215A with ch2 inoperative and a 475 that's screwed up so there's plenty of business for such a service. Any help would be greatly appreciated, Peter |
Re: Switch won't latch - 7CT1N
Rolynn
I'm sure you mean well, but there are no switches on any 7CT1N that are immediately behind the front panel. The shaft in question is six inches long, as I already stated. It is already obvious that the cleaning material should be introduced directly into the switch, not via gravity feed from the front panel, which is entirely infeasible. I have already done everything mentioned here with no improvement whatsoever. Evidently the issue is mechanical damage to the small rod's track. EJP |
Re: 2213A Novice, unsolved anomaly encountered, documented & video
Hi Gary,
It might be helpful to drive an input from the 'probe adjust' output to be able to observe the state of the vertical when the horizontal collapses. Just a solid wire from probe adjust to the centre of the BNC will suffice. This would also expose the state of the trigger circuits as the collapse happens. Cheers, Brian. |
Re: 91% Isopropyl Rubbing Alcohol to clean potentiometers?
This topic has a dangerous habit of feeding on itself with information that has only tangential relevance to the subject of TekScopes.
I understand that we have more than a few members with chemistry backgrounds who can expound on this topic ad-infinitum, In addition there are many members with their own stories or experiences. At this point there is very little of value that can be added to the pros and cons of using Isopropyl Alcohol on TekScopes. But each time someone tries it seems to annoy the vast majority of our members who, I can only conclude, seem to prefer their scopes dirty. In deference to the majority I am requesting that this topic be put to bed for once and for all. Thank you, Dennis Tillman W7PF -- Dennis Tillman W7PF TekScopes Moderator |
Re: 2213A Novice, unsolved anomaly encountered, documented & video
tom jobe
I hope the 2213A owner follows JC's test plan, or some variation of it.
toggle quoted message
Show quoted text
The 2213A needs a good logical plan to find this most unusual failure. It's great to hear that David Hess has been helping him on this project over on the EEV Blog! There are plenty of 22xx parts available once this mystery is solved. tom jobe... On 3/22/2019 4:45 PM, chipbee40 via Groups.Io wrote:
Looking at your Youtube, something is obviously failing with heat so freeze spray would be helpful (upturned canned air is fine). My initial thought was U760 as the timebase is collapsing but I've not seen one fail such that the power led would flicker. Unplug the timebase, see if it still fails. (You are looking for the power LED to flicker, nice symptom, unusual!). Surprised the scope isn't tripping completely. I'd suggest monitoring the power rails to see if its just one rail failing or all rails. Complicated with switching supplies because all will drop on overload as the switcher detects a fault but not impossible to ascertain which rail is overloading. I would start by disconnecting the feed to the multiplier (so nothing on screen) and just observing the power led (or monitor the supplies) for any failings. You can also remove power to the attenuator board, an unlikely culprit but I have had the opamps go short. You could just pull all the power supply links and monitor the rails but without a load the fault might not show. What is the Y amp doing when it fails? Amplitude still good? Your replacement parts look ok. Hopefully you have checked the obvious, I've received these with loose screws jammed in unlikely places, solder bridges due to careless repairs. JC |
Re: 2213A Novice, unsolved anomaly encountered, documented & video
My first scope was a 2213A. I got it from the auction site. Stated all was working 100%. After powering on for several minutes it would lose its trace and go crazy. The previous owner had removed the board and there are little tabs that hold the board in place. One side of the board was not fit into the tab and the board was bent. after removing the board and making sure the board was in its proper place it has worked fine since and that was 7 years ago.
Brendan |
Re: 2213A Novice, unsolved anomaly encountered, documented & video
Looking at your Youtube, something is obviously failing with heat so freeze spray would be helpful (upturned canned air is fine). My initial thought was U760 as the timebase is collapsing but I've not seen one fail such that the power led would flicker. Unplug the timebase, see if it still fails. (You are looking for the power LED to flicker, nice symptom, unusual!). Surprised the scope isn't tripping completely. I'd suggest monitoring the power rails to see if its just one rail failing or all rails. Complicated with switching supplies because all will drop on overload as the switcher detects a fault but not impossible to ascertain which rail is overloading. I would start by disconnecting the feed to the multiplier (so nothing on screen) and just observing the power led (or monitor the supplies) for any failings. You can also remove power to the attenuator board, an unlikely culprit but I have had the opamps go short. You could just pull all the power supply links and monitor the rails but without a load the fault might not show. What is the Y amp doing when it fails? Amplitude still good? Your replacement parts look ok. Hopefully you have checked the obvious, I've received these with loose screws jammed in unlikely places, solder bridges due to careless repairs. JC
|
Re: 2213A Novice, unsolved anomaly encountered, documented & video
Nope, no break for Dave Hess; He's on TekScopes, too!Jim Ford?Sent from my Verizon, Samsung Galaxy smartphone
toggle quoted message
Show quoted text
-------- Original message --------From: guy232 <gry.russel@...> Date: 3/22/19 11:55 AM (GMT-08:00) To: [email protected] Subject: [TekScopes] 2213A Novice, unsolved anomaly encountered, documented & video Hello fellas! I have been reading/researching a ton over the past couple months while trying to get my new to me 2213A in proper working order. I bought one from the auction site and powered it on for less than a minute, seemed alright. Powered it down because I seen that its highly recommended to replace the power supply area electrolytics & safety caps before doing the initial LVPS tests.I have been documenting this on eevblog forum and have had some great help there from David Hess, thought I may post here too just to document my issue for others and maybe get some insight to give poor Mr. Hess a break from me, hah!In hopes of making this more concise and readable, I will section things up as such:- briefly explaining the anomaly & including a video link- listing the components I replaced- listing the 2 instances of my novice induced damage/mistakes I encountered. (I dont believe these are related to the anomaly though)----------------Anomaly: After replacing parts I powered up with scope settings set to "Baseline Trace", traces displays and everything looks good. After 2-3 minutes the trace starts shrinking, blinking and slowly fades out. The power led/trigger led also fade in and out during this time. After 10 or so seconds the power led finally goes dark and the machine displays nothing. Toggling power on/off doesnt help. After unplugging and waiting an hour or so and then trying to power on the unit works but will repeat the same process again in 2-3min.Video of the anomaly, feel free to skip to 2:19 which is when it starts to occur:? the suggestion of Mr. Hess; I checked temperatures of a few components in the power supply area right after the anomaly occured. All areas seem normal (24-27C). The "highest" temp was 29-30C on T944. Mr. Hess advised that these temperatures seemed alright and if a transformer was the cause I would expect to see very high readings.After much more reading around I haven't found any good leads in the right direction yet. Will keep this updated!-----------------------Parts replaced:C900: KEMET?R46 Series?FILM 0.15UF 10% 560VDC RADC902, C903, C904: KEMET Y2 Rating Film 2200pf 1kvdcC906: United Chemicon KXJ series?100?F?450VC925: Chemicon KY?100?F 25V?C940: Chemicon KYB?1200?F 63V?C942, C943: Nichicon UCS?10uf 160vC944: Kemet R82 Series?1?F Film Capacitor 40V 63V Polyester, Polyethylene Terephthalate (PET), MetallizedC954: Chemicon kxj?39?F 160V?C960-C970:? Chemicon KYB?1000UF 20% 25V?R892, 894, 888, 889, 890, 891: Vishay HVR37 510K 1/2W 1%Schaffner AC inlet/IEC: Qualtek?858-03/007------------------------------------Accidents/Errors/Damage:C944, Positive lead;? Lifted pad on bottom of board. The top side of the board still has pad intact. Used multimeter on bottom side of the board and the C944 positive lead shares continuity with other components connected to the ground, I believe this means that the lifted bottom pad isn't a big deal that requires repair.C956: I made a mistake due to the capacitor list I was using being incorrect. Initially installed a Nichicon UPW?47?F 63V cap. I caught this mistake and replaced it with the stock 270uf +100-10% 40V cap which still tested good for ESR & Capacitance. Ordered & waiting on new cap (nichicon upw 330uf 50v). Not sure if powering on with this cap caused any damage but after removing the 47uf cap it still tested good, replacing the stock 270uf cap did not solve the scope anomaly.----------------------------Thanks for any insight, I will still be researching meanwhile and will update if I find anything out.Cheers,Gary R.Treasure Coast, Florida
|
2213A Novice, unsolved anomaly encountered, documented & video
Hello fellas! I have been reading/researching a ton over the past couple months while trying to get my new to me 2213A in proper working order.
I bought one from the auction site and powered it on for less than a minute, seemed alright. Powered it down because I seen that its highly recommended to replace the power supply area electrolytics & safety caps before doing the initial LVPS tests. I have been documenting this on eevblog forum and have had some great help there from David Hess, thought I may post here too just to document my issue for others and maybe get some insight to give poor Mr. Hess a break from me, hah! In hopes of making this more concise and readable, I will section things up as such: - briefly explaining the anomaly & including a video link - listing the components I replaced - listing the 2 instances of my novice induced damage/mistakes I encountered. (I dont believe these are related to the anomaly though) ---------------- Anomaly: After replacing parts I powered up with scope settings set to "Baseline Trace", traces displays and everything looks good. After 2-3 minutes the trace starts shrinking, blinking and slowly fades out. The power led/trigger led also fade in and out during this time. After 10 or so seconds the power led finally goes dark and the machine displays nothing. Toggling power on/off doesnt help. After unplugging and waiting an hour or so and then trying to power on the unit works but will repeat the same process again in 2-3min. Video of the anomaly, feel free to skip to 2:19 which is when it starts to occur: ? Under the suggestion of Mr. Hess; I checked temperatures of a few components in the power supply area right after the anomaly occured. All areas seem normal (24-27C). The "highest" temp was 29-30C on T944. Mr. Hess advised that these temperatures seemed alright and if a transformer was the cause I would expect to see very high readings. After much more reading around I haven't found any good leads in the right direction yet. Will keep this updated! ----------------------- Parts replaced: C900: KEMET?R46 Series?FILM 0.15UF 10% 560VDC RAD C902, C903, C904: KEMET Y2 Rating Film 2200pf 1kvdc C906: United Chemicon KXJ series?100?F?450V C925: Chemicon KY?100?F 25V? C940: Chemicon KYB?1200?F 63V? C942, C943: Nichicon UCS?10uf 160v C944: Kemet R82 Series?1?F Film Capacitor 40V 63V Polyester, Polyethylene Terephthalate (PET), Metallized C954: Chemicon kxj?39?F 160V? C960-C970:? Chemicon KYB?1000UF 20% 25V? R892, 894, 888, 889, 890, 891: Vishay HVR37 510K 1/2W 1% Schaffner AC inlet/IEC: Qualtek?858-03/007 ------------------------------------ Accidents/Errors/Damage: C944, Positive lead;? Lifted pad on bottom of board. The top side of the board still has pad intact. Used multimeter on bottom side of the board and the C944 positive lead shares continuity with other components connected to the ground, I believe this means that the lifted bottom pad isn't a big deal that requires repair. C956: I made a mistake due to the capacitor list I was using being incorrect. Initially installed a Nichicon UPW?47?F 63V cap. I caught this mistake and replaced it with the stock 270uf +100-10% 40V cap which still tested good for ESR & Capacitance. Ordered & waiting on new cap (nichicon upw 330uf 50v). Not sure if powering on with this cap caused any damage but after removing the 47uf cap it still tested good, replacing the stock 270uf cap did not solve the scope anomaly. ---------------------------- Thanks for any insight, I will still be researching meanwhile and will update if I find anything out. Cheers, Gary R. Treasure Coast, Florida |
Re: 91% Isopropyl Rubbing Alcohol to clean potentiometers?
Chuck Harris
From my table of polarity of solvents, isopropanol, and indeed ethanol and methanol,
toggle quoted message
Show quoted text
are all much more polar than acetone. If it is water soluble, it is most likely polar. If it is insoluble in water, it is most likely nonpolar. Water (Very Polar) Acetic Acid Ethyleneglycol Methanol Ethanol Isopropanol Pyridine Acetonitrile Nitromethane Diehylamine Aniline Dimethylsulfoxide Ethylacetate Dioxane Acetone Dicholoroethane Tetrahydrofuran Dicholoromethane Chloroform Diethylether Benzene Toluene Xylene Carbontetrachloride Cyclohexane Petroleum ether Hexane Pentane (Non Polar) -Chuck Harris thespin@... wrote: The thing to remember is in general ¡°like dissolves like¡± with solvents, where like refers to non-polar dissolves non-polar gunk, and polar dissolves polar gunk. IPA is non-polar, acetone is polar, and most grease is polar. Acetone here is probably too aggressive. Try deoxit products for potentiometers. |
to navigate to use esc to dismiss