Date
Re: 7704A, good deal?
Does that mean it can trigger from a S-52?
By Stephen · #188988 ·
Re: 7704A, good deal?
Thanks. I printed it out for quick reference this evening when I do what you said.
By Stephen · #188987 ·
Re: Tektronix 2430A
Siggi's reply is a very good summary, just to amplify a couple of points: The 2430A digitises at 100Msamples/sec, the rule of thumb is that the useful bandwidth for a single shot acquisition is 1/5th
By Roger Evans · #188986 ·
Re: 7704A, good deal?
Sorry, I also added a redirect on the wiki so clicking the link will work now.
By Peter H · #188985 ·
Re: 7704A, good deal?
To my knowledge, and per a quick reading of the manual, the 7S12 doesn't trigger from the sampling head (left-hand head slot), only from the right-hand head which can be a pulser (for TDR), or an S-53
By Peter H · #188984 ·
Disregard [Re: [TekScopes] Help for a 7904 with -12V problem}
In the cold light of day I see that I was probing on the wrong pads.... Still no -12V but not the short I though I had... I'll be back when I have better data Dave manuals@...
By Dave / NR1DX · #188983 ·
Re: 7704A, good deal?
Thanks Raymond. Notes. I¡¯ll see how it turns out this evening.
By Stephen · #188982 ·
Re: 465 back from the dead? Many questions for the tech guys here.
You might try this link and see if the manual is any better: https://download.tek.com/manual/tek-465.pdf
By k7rgydave@... · #188981 ·
Help for a 7904 with -12V problem
Shaggy Dog Summary: Bought a 7A13 plug-in , Known " not working" but no detail. Plugged it in and the 7904 stopped working...8^( Troubleshooting trail so far: 7904 serial B257xxx. Which means it uses
By Dave / NR1DX · #188980 ·
Looking for, ¡°TroubleShooting your TEK Oscilloscope Military Virsion¡±
I¡¯m looking for the military version of Troubleshooting your Oscilloscope I was told it went into deeper detail of how too step by step. Andrew
By KB2LMN <acurlik@...> · #188979 ·
Re: 067-0502-01 CALIBRATION FIXTURE
Grrr, you are right Raymond! I forgot about that part of the story. Nevertheless I think my "theory" is correct, though the differences between tube emissions might be not large enough to change the
By Albert Otten · #188978 ·
Re: 7704A, good deal?
Repairing a complete 7S12 in TDR setup often isn't straightforward, especially with limited equipment and no spare parts. Therefore, a unit that is not fully functional would only have spare parts
By Raymond Domp Frank · #188977 ·
Re: 7704A, good deal?
Raymond, That¡¯s exactly why I¡¯ve asked for advice on how to do an initial check to see if EVERYTHING is functioning properly. If¡¯s it¡¯s not fully operational, what would you consider a good
By Stephen · #188976 ·
Re: 067-0502-01 CALIBRATION FIXTURE
I think there's a misunderstanding here. Stephen initially replaced the original 200pF caps with 250pF caps. That's what caused the lower frequency. As soon as he corrected the RC-times to match the
By Raymond Domp Frank · #188975 ·
Re: 7704A, good deal?
You have to be aware that the 7S12-set that you describe is a TDR unit, not a general purpose sampling 'scope plugin. The S-6 does not supply a trigger signal to the 'scope. A sampling 'scope needs a
By Raymond Domp Frank · #188974 ·
Re: 7704A, good deal?
Probably. I just clicked on it¡­ Thanks
By Stephen · #188973 ·
Re: 7704A, good deal?
You probably included the ":" at the end of the link. Enter the link without it and the link works. Raymond
By Raymond Domp Frank · #188972 ·
Re: 7D15 Character Display
That's an interesting document on Tekwiki!
By NigelP · #188971 ·
Re: 7704A, good deal?
Thank you Peter, but your link links to no image¡­
By Stephen · #188970 ·
Re: 465 back from the dead? Many questions for the tech guys here.
I have a similar problem on my TEK 475 after repairing the +15V stabilised rail (shortcircuited by a tantalum C on the rail) and finding/repairing a second problem (an intermittent problem in the HV
By Redguuz · #188969 ·